fix(orchestrator): run semantic control mapping on PLC findings (#229)
This commit was merged in pull request #229.
This commit is contained in:
@@ -586,7 +586,21 @@ impl PipelineOrchestrator {
|
||||
let Some(path) = ingest_set.get(&a.id).and_then(|ia| ia.working_path.clone()) else {
|
||||
continue;
|
||||
};
|
||||
all_findings.extend(crate::pipeline::plc::analyze_tree(&path, target_id));
|
||||
let mut source_findings = crate::pipeline::plc::analyze_tree(&path, target_id);
|
||||
// Control mapping for the PLC path (run_plc_scan is separate from
|
||||
// run_pipeline, which does its own mapping). PLC findings carry
|
||||
// file_path/line/cwe, so the semantic pass reads each region under this
|
||||
// source's `path` and stamps master-control refs. The LUT + grounded
|
||||
// surface passes are code-pattern / CRA-specific and don't apply to
|
||||
// IEC 61131-3 control logic, so only the semantic pass runs here.
|
||||
crate::controls::semantic_stamp_findings(
|
||||
&self.config,
|
||||
self.llm.clone(),
|
||||
&path,
|
||||
&mut source_findings,
|
||||
)
|
||||
.await;
|
||||
all_findings.extend(source_findings);
|
||||
// Control-application SBOM: CODESYS libraries + runtime from a
|
||||
// `.projectarchive` (uploaded, or committed in the working tree).
|
||||
let archive = a
|
||||
|
||||
Reference in New Issue