4d1e0a7f8e
Systematic gap analysis of the Bremse ground-truth file (60 entries,
100 unique expert measures) revealed only ~5% library coverage. This
commit closes the documented gaps with concrete, norm-anchored
mitigations.
Library additions (M481-M539, 59 entries):
- M481-M482 Low-voltage isolation (>= 2,0 / 2x1,0 / 1,0 MOhm +
IP2X/IPXXB per EN 60204-1 Ziff. 6.2/8.2.3) — primary
trigger of this work
- M483-M485 Pneumatic safety (component pressure rating, hose
retention, depressurization per EN ISO 4414)
- M486-M490 Robot-cell access (tool-secured fence, dual-channel
door monitor, intentional restart, anti-trap inside
opening, HMI sight line per ISO 10218-2)
- M491-M493 Teach mode (key/password mode selector, safe reduced
speed <= 250 mm/s, hold-to-run with 3-stage enabler
per ISO 10218-1)
- M494-M500 Geometry constants (Safe Limited Position, reach-over
250 mm @ 2250 mm fence, conveyor opening >= 850 mm,
25 mm finger gap, band speed <= 100 mm/s per
EN ISO 13857 / EN 619)
- M501-M507 Enclosure load rating, gripper fail-safe, centring
gripper stop on door, MWF nozzle integration, floor
load capacity per DIN 1055-3
- M508-M517 Electrical cabling + PE protection (environment-rated,
drag chain, strain relief, 10 mm² Cu PE, dual PE,
monitoring, continuity check, class-II equipment,
SELV/PELV per EN 60204-1)
- M518-M522 RCD, cable cross-section, overcurrent in each active
conductor, IP22 water ingress, lockable main switch
- M523-M539 Teach-locked door, WZM door interlock, dual-channel
door switch, machining-doors-closed for aerosol
retention, post-NOTHALT release, >25 kg lifting aid
(DGUV 208-016), 95-120 cm control height, ergonomic
conveyor height, SDS/PSA reference, BA instructions
for depressurization/clamp release/max weight/pinch
warning/slip warning/dead-state cleaning
New hazard patterns (HP1710-HP1717):
floor overload, gripper failure throw, compressed-air injury in
machining cell, manual handling load + awkward posture, MWF skin
contact, live-cabinet cleaning short, pneumatic stored-energy.
Existing patterns rewired to the new measures: HP1600, HP1602-1606,
HP1610-1612, HP1620-1622, HP1630/1631/1633, HP1640/1641, HP1660/1661,
HP1675, HP1685, HP1688, HP1689, HP1698-1704.
Tooling:
- scripts/gt_measure_gap_analysis.py: 4-signal fuzzy matcher
(Jaccard, token recall, substring containment, norm-reference
overlap). Outputs markdown + JSON.
- gt_coverage_test.go: 23 expert-validated (GT-Nr, pattern, measure)
triples + a norm-reference presence test for every new expert
measure (no generic 'do X safely' entries allowed).
- .gitea/workflows/ci.yaml: new iace-gt-coverage job enforces
MIN_COVERAGE_PCT (70%) on Strong+Weak GT coverage; never lower
without explicit decision.
Coverage shift: 5% Strong -> 30% Strong, 0% -> 72% Strong+Weak.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
360 lines
23 KiB
Go
360 lines
23 KiB
Go
package iace
|
|
|
|
// GetRobotCellPatterns returns hazard patterns for industrial robot cells
|
|
// (non-collaborative) with safety fence, conveyors, and CNC machine tools.
|
|
// Based on typical ISO 10218-2 risk assessment scope for integrated robot systems.
|
|
//
|
|
// FORMULIERUNGSREGEL: Gefährdung und Szenario NEUTRAL formulieren — keine
|
|
// Lebensphasen im Text. Lebensphasen stehen in ApplicableLifecycles.
|
|
// HP1600-HP1649
|
|
func GetRobotCellPatterns() []HazardPattern {
|
|
return []HazardPattern{
|
|
// ================================================================
|
|
// Roboterarm — Quetschen/Einklemmen von Personen
|
|
// ================================================================
|
|
{
|
|
ID: "HP1600", NameDE: "Einklemmen zwischen Roboterarm und Anlage", NameEN: "Crushing between robot arm and fixed structure",
|
|
RequiredComponentTags: []string{"moving_part"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M487", "M488", "M494", "M054", "M061"},
|
|
Priority: 99, MachineTypes: []string{"robotics_cobot", "automotive", "metalworking", "general_industry"},
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "teach_mode", "cleaning", "maintenance", "fault_clearing", "changeover"},
|
|
ScenarioDE: "Person befindet sich im Bewegungsbereich des Roboterarms und wird zwischen Roboterarm und feststehenden Anlagenteilen eingeklemmt.",
|
|
TriggerDE: "Roboterarm bewegt sich waehrend Person im Gefahrenbereich steht.",
|
|
HarmDE: "Quetschungen, Knochenbrueche, innere Verletzungen durch Einklemmen von Koerperteilen.",
|
|
AffectedDE: "Bedienpersonal, Einrichter, Wartungspersonal, Reinigungspersonal",
|
|
ZoneDE: "Roboterarm, feststehende Anlagenteile innerhalb der Roboterzelle",
|
|
DefaultSeverity: 4, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1602", NameDE: "Durchgreifen durch Schutzzaun zum Roboter", NameEN: "Reaching through safety fence to robot",
|
|
RequiredComponentTags: []string{"moving_part", "guard"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M495", "M486", "M002", "M061"},
|
|
Priority: 98,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Person greift ueber oder durch den Schutzzaun und erreicht den Bewegungsbereich des Roboterarms.",
|
|
TriggerDE: "Unzureichender Sicherheitsabstand zwischen Schutzzaun-Oberkante und Roboter-Schwenkbereich.",
|
|
HarmDE: "Quetschung von Hand oder Arm zwischen Roboterarm und feststehenden Teilen.",
|
|
AffectedDE: "Bedienpersonal, Reinigungspersonal",
|
|
ZoneDE: "Schutzzaun-Oberkante, Roboterarm",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1603", NameDE: "Eingeschlossen in Roboterzelle", NameEN: "Trapped inside robot cell",
|
|
RequiredComponentTags: []string{"moving_part", "guard"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M489", "M490", "M488", "M487"},
|
|
Priority: 99,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "maintenance", "fault_clearing", "changeover"},
|
|
ScenarioDE: "Person befindet sich in der Roboterzelle, Schutztuer wird geschlossen und Roboter startet. Person kann den Gefahrenbereich nicht rechtzeitig verlassen.",
|
|
TriggerDE: "Schutztuer schliesst waehrend Person im Innenraum. Wiederanlauf des Roboters ohne Quittierung.",
|
|
HarmDE: "Quetschungen, Stoss durch anlaufenden Roboter.",
|
|
AffectedDE: "Wartungspersonal, Einrichter, Reinigungspersonal",
|
|
ZoneDE: "Inneres der Roboterzelle",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1604", NameDE: "Roboterarm durchschlaegt Schutzzaun", NameEN: "Robot arm penetrates safety fence",
|
|
RequiredComponentTags: []string{"moving_part", "guard"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M494", "M501", "M061"},
|
|
Priority: 98,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "changeover", "fault_clearing"},
|
|
ScenarioDE: "Roboterarm ueberschreitet Bewegungsbereich und trifft Schutzzaun. Person ausserhalb wird von Zaunteilen oder dem Roboterarm getroffen.",
|
|
TriggerDE: "Fehler in der Bahnplanung oder Ausfall der Achsbegrenzung.",
|
|
HarmDE: "Teile des Schutzzauns werden herausgeschleudert, Person ausserhalb wird getroffen.",
|
|
AffectedDE: "Bedienpersonal in der Naehe des Schutzzauns",
|
|
ZoneDE: "Schutzzaun, Bereich um die Roboterzelle",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1605", NameDE: "Stoss durch Werkzeug/Greifer im Einrichtbetrieb", NameEN: "Impact by tool/gripper during setup",
|
|
RequiredComponentTags: []string{"moving_part", "clamping_part"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M491", "M492", "M493", "M054"},
|
|
Priority: 98, MachineTypes: []string{"robotics_cobot", "automotive", "metalworking", "general_industry"},
|
|
ApplicableLifecycles: []string{"teach_mode", "setup", "changeover", "fault_clearing"},
|
|
ScenarioDE: "Person steht im Bewegungsbereich des Roboterarms und wird von bewegtem Werkzeug oder Greifer getroffen. Geschwindigkeitsreduzierung im Einrichtbetrieb reicht nicht aus.",
|
|
TriggerDE: "Roboter bewegt Werkzeug/Greifer mit unerwartet hoher Geschwindigkeit oder in unerwartete Richtung.",
|
|
HarmDE: "Prellungen, Quetschungen durch Kontakt mit Werkzeug/Greifer am Roboterarm.",
|
|
AffectedDE: "Einrichter, Programmierer, Wartungspersonal",
|
|
ZoneDE: "Inneres der Roboterzelle, Schwenkbereich Werkzeug/Greifer",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
// ================================================================
|
|
// Greifer / Werkstueck
|
|
// ================================================================
|
|
{
|
|
ID: "HP1610", NameDE: "Quetschen im Greiferbereich", NameEN: "Crushing in gripper area",
|
|
RequiredComponentTags: []string{"clamping_part"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M503", "M487", "M054", "M061"},
|
|
Priority: 99, MachineTypes: []string{"robotics_cobot", "automotive", "metalworking", "general_industry"},
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "changeover", "fault_clearing"},
|
|
ScenarioDE: "Person greift in den Bereich des Greifers. Hand wird zwischen Greifbacken und Werkstueck eingeklemmt.",
|
|
TriggerDE: "Greiferbacken schliessen waehrend Koerperteil im Greifbereich ist.",
|
|
HarmDE: "Quetschung oder Amputation von Fingern durch Greifkraft.",
|
|
AffectedDE: "Bedienpersonal, Einrichter",
|
|
ZoneDE: "Greifer des Roboterarms, Werkstueckaufnahme",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1611", NameDE: "Werkstueck faellt aus Greifer herab", NameEN: "Workpiece falls from gripper",
|
|
RequiredComponentTags: []string{"clamping_part"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M502", "M007", "M141"},
|
|
Priority: 98,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "changeover"},
|
|
ScenarioDE: "Greifer verliert das Werkstueck waehrend des Transports. Werkstueck faellt herab und trifft Person unterhalb des Roboterarms.",
|
|
TriggerDE: "Werkstueck faellt aus Greifer und trifft Person unterhalb des Roboterarms.",
|
|
HarmDE: "Prellungen, Knochenbrueche abhaengig von Werkstueckgewicht und Fallhoehe.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal",
|
|
ZoneDE: "Bereich unterhalb des Greifer/Roboterarms",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1612", NameDE: "Werkstueck durchschlaegt Einhausung", NameEN: "Workpiece penetrates enclosure",
|
|
RequiredComponentTags: []string{"clamping_part", "guard"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M501", "M502", "M061"},
|
|
Priority: 98,
|
|
ApplicableLifecycles: []string{"normal_operation"},
|
|
ScenarioDE: "Greifer versagt und Werkstueck wird in Richtung Schutzzaun geschleudert. Person ausserhalb der Zelle wird von durchschlagendem Werkstueck getroffen.",
|
|
TriggerDE: "Werkstueck wird durch Roboterbewegung weggeschleudert und durchschlaegt die Schutzeinrichtung.",
|
|
HarmDE: "Person ausserhalb der Zelle wird von weggeschleudertem Werkstueck getroffen.",
|
|
AffectedDE: "Bedienpersonal in der Naehe der Roboterzelle",
|
|
ZoneDE: "Schutzzaun, Bereich um die Roboterzelle",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
// ================================================================
|
|
// Foerderbaender / Werkstueckzu-/-auslauf
|
|
// ================================================================
|
|
{
|
|
ID: "HP1620", NameDE: "Quetschen an Foerderband-Einlauf", NameEN: "Crushing at conveyor infeed",
|
|
RequiredComponentTags: []string{"entanglement_risk"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M498", "M499", "M002", "M061"},
|
|
Priority: 98,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Person greift an Foerderband und wird zwischen beweglichen und feststehenden Teilen eingeklemmt.",
|
|
TriggerDE: "Hand oder Finger geraten zwischen Band und Umlenkrolle oder zwischen Werkstueck und Tunnelrahmen.",
|
|
HarmDE: "Quetschung von Fingern, Einzug von Kleidung oder Haaren.",
|
|
AffectedDE: "Bedienpersonal, Reinigungspersonal",
|
|
ZoneDE: "Foerderbaender, Bandein- und -auslauf",
|
|
DefaultSeverity: 2, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1621", NameDE: "Durchgreifen durch Foerderband-Oeffnung in Schutzzaun", NameEN: "Reaching through conveyor opening in fence",
|
|
RequiredComponentTags: []string{"entanglement_risk", "guard"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M496", "M497", "M498", "M002"},
|
|
Priority: 98,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "fault_clearing"},
|
|
ScenarioDE: "Person greift durch die Oeffnung im Schutzzaun fuer die Foerderbaender in den Gefahrenbereich des Roboters.",
|
|
TriggerDE: "Oeffnung ist zu gross oder Sicherheitsabstand zum Roboter-Schwenkbereich ist zu gering.",
|
|
HarmDE: "Quetschung von Hand oder Arm durch Roboterarm oder bewegte Maschinenteile.",
|
|
AffectedDE: "Bedienpersonal",
|
|
ZoneDE: "Oeffnung der Foerderbaender im Schutzzaun, Roboterbereich dahinter",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1622", NameDE: "Herunterfallen von Werkstueck am Bandende", NameEN: "Workpiece falling off conveyor end",
|
|
RequiredComponentTags: []string{"entanglement_risk"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M500", "M008"},
|
|
Priority: 97,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup"},
|
|
ScenarioDE: "Werkstueck faehrt ueber das Ende des Transportbandes hinaus, faellt herab und trifft Person am Be-/Entladeplatz.",
|
|
TriggerDE: "Mechanischer Anschlag fehlt oder ist beschaedigt.",
|
|
HarmDE: "Prellungen, Quetschung von Fuessen durch herabfallendes Werkstueck.",
|
|
AffectedDE: "Bedienpersonal am Be-/Entladeplatz",
|
|
ZoneDE: "Ende der Transportbaender, Be-/Entladeplatz",
|
|
DefaultSeverity: 2, DefaultExposure: 3,
|
|
},
|
|
// ================================================================
|
|
// Scharfe Kanten / Allgemein
|
|
// ================================================================
|
|
{
|
|
ID: "HP1625", NameDE: "Schneiden an scharfen Kanten der Einhausung", NameEN: "Cutting on sharp enclosure edges",
|
|
RequiredComponentTags: []string{"guard"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M003"},
|
|
Priority: 97,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Person schneidet sich an nicht entgrateten oder scharfkantigen Blechen der Einhausung oder Verkleidung.",
|
|
TriggerDE: "Zugaengliche Kanten sind nicht gerundet oder gebrochen.",
|
|
HarmDE: "Schnittwunden an Haenden und Armen.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal, Reinigungspersonal",
|
|
ZoneDE: "Zugaengliche Kanten der Maschine und Einhausung",
|
|
DefaultSeverity: 2, DefaultExposure: 3,
|
|
},
|
|
// ================================================================
|
|
// Pneumatik / Druckluft
|
|
// ================================================================
|
|
{
|
|
ID: "HP1630", NameDE: "Pneumatikschlauch springt unter Druck ab", NameEN: "Pressurized hose comes loose",
|
|
RequiredComponentTags: []string{"pinch_point"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M483", "M484", "M485"},
|
|
Priority: 97,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Pneumatikschlauch der Automation springt unter Druck ab und trifft eine Person (Peitscheneffekt).",
|
|
TriggerDE: "Befestigung loest sich, Verschraubung wird undicht, Materialermuedung des Schlauchs.",
|
|
HarmDE: "Prellungen, Augenverletzungen durch abspringenden Schlauch.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal",
|
|
ZoneDE: "Pneumatikschlaeuche der Automation",
|
|
DefaultSeverity: 2, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1631", NameDE: "Restdruck in Pneumatik nach Abschaltung", NameEN: "Residual pressure in pneumatics after shutdown",
|
|
RequiredComponentTags: []string{"pinch_point"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M485", "M483", "M141"},
|
|
Priority: 97,
|
|
ApplicableLifecycles: []string{"maintenance", "fault_clearing", "changeover"},
|
|
ScenarioDE: "Person loest druckbeaufschlagte Pneumatik-Komponenten die nach Abschaltung noch unter Druck stehen. Teile fliegen unkontrolliert weg und treffen die Person.",
|
|
TriggerDE: "Fehlende Druckentlastung. Gesperrte Rueckschlagventile halten Druck.",
|
|
HarmDE: "Person wird von wegfliegenden Teilen oder unkontrolliert loesenden Verbindungen getroffen. Prellungen, Schnittverletzungen.",
|
|
AffectedDE: "Wartungspersonal, Einrichter",
|
|
ZoneDE: "Pneumatikschlaeuche und -komponenten",
|
|
DefaultSeverity: 2, DefaultExposure: 2,
|
|
},
|
|
// ================================================================
|
|
// Kuehlschmierstoff (KSS)
|
|
// ================================================================
|
|
{
|
|
ID: "HP1606", NameDE: "Quetschen/Scheren durch Greifer im Einrichtbetrieb", NameEN: "Crushing/shearing by gripper during setup",
|
|
RequiredComponentTags: []string{"clamping_part"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M491", "M492", "M493", "M054"},
|
|
Priority: 98, MachineTypes: []string{"robotics_cobot", "automotive", "metalworking", "general_industry"},
|
|
ApplicableLifecycles: []string{"teach_mode", "setup", "changeover", "fault_clearing"},
|
|
ScenarioDE: "Einrichter steht im Schwenkbereich des Roboterarms und wird von bewegtem Greifer oder daran befestigtem Werkzeug verletzt.",
|
|
TriggerDE: "Reduzierte Geschwindigkeit im Einrichtbetrieb reicht nicht aus oder wird nicht aktiviert.",
|
|
HarmDE: "Quetschung, Schnittverletzung durch Greiferkanten oder Werkzeug am Roboter.",
|
|
AffectedDE: "Einrichter, Programmierer",
|
|
ZoneDE: "Inneres der Roboterzelle, Greifer/Werkzeug am Roboterarm",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1634", NameDE: "KSS-Pumpe spritzt bei geoeffneter Schutztuer", NameEN: "Coolant pump sprays with open guard door",
|
|
RequiredComponentTags: []string{},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M061"},
|
|
Priority: 96, MachineTypes: []string{"cnc", "metalworking", "automotive"},
|
|
ApplicableLifecycles: []string{"normal_operation", "cleaning", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Niederdruck-Pumpe fuer Bettspuelung laeuft an waehrend Schutztuer geoeffnet ist. Person bekommt KSS-Spritzer ins Auge oder Gesicht.",
|
|
TriggerDE: "Pumpe startet automatisch, kein Verriegelungssignal von Schutztuer zur KSS-Pumpe.",
|
|
HarmDE: "Augenverletzung durch KSS-Spritzer, Hautreizung.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal",
|
|
ZoneDE: "Bearbeitungszelle, Austrittsduesen der Bettspuelung",
|
|
DefaultSeverity: 1, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1633", NameDE: "KSS-Versorgungsschlauch platzt oder reisst ab", NameEN: "Coolant supply hose bursts or tears off",
|
|
RequiredComponentTags: []string{},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M484", "M483"},
|
|
Priority: 97, MachineTypes: []string{"cnc", "metalworking", "automotive"},
|
|
ApplicableLifecycles: []string{"normal_operation", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "KSS-Versorgungsschlauch reisst ab oder platzt. Person in der Naehe wird von abspringendem Schlauch oder KSS-Strahl unter Druck getroffen.",
|
|
TriggerDE: "Materialermuedung, mechanische Beschaedigung, fehlerhafte Befestigung des Schlauchs.",
|
|
HarmDE: "Person wird von KSS-Strahl getroffen. Einstichverletzung, Hautreizung, Rutschgefahr.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal",
|
|
ZoneDE: "Druckschlaeuche des Kuehlschmierstoffsystems, Verbindungsstellen",
|
|
DefaultSeverity: 2, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1635", NameDE: "Ausrutschen durch KSS-Leckage", NameEN: "Slipping due to coolant leakage",
|
|
RequiredComponentTags: []string{},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M420"},
|
|
Priority: 97, MachineTypes: []string{"cnc", "metalworking", "automotive"},
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Kuehlschmierstoff tritt aus und bildet rutschigen Belag auf dem Boden. Person rutscht aus und stuerzt.",
|
|
TriggerDE: "Leckage an Schlauchverbindung, Dichtungsversagen.",
|
|
HarmDE: "Ausrutschen und Sturz, Prellungen, Knochenbrueche.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal",
|
|
ZoneDE: "Boden um Bearbeitungszentrum und Kuehlschmierstoffanlage",
|
|
DefaultSeverity: 2, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1636", NameDE: "Hautkontakt mit Kuehlschmierstoff", NameEN: "Skin contact with coolant",
|
|
RequiredComponentTags: []string{},
|
|
GeneratedHazardCats: []string{"material_environmental"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
Priority: 97, MachineTypes: []string{"cnc", "metalworking", "automotive"},
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Person kommt bei Arbeiten am Bearbeitungszentrum oder der Roboterzelle mit Kuehlschmierstoff in Beruehrung.",
|
|
TriggerDE: "Hautkontakt beim Reinigen, Werkzeugwechsel oder Beseitigung von Stoerungen.",
|
|
HarmDE: "Hautirritationen, allergische Reaktionen, bei laengerer Exposition Ekzeme.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal",
|
|
ZoneDE: "Bearbeitungszentrum, Roboterzelle im Bereich der Beladetuer",
|
|
DefaultSeverity: 1, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1637", NameDE: "Einatmen von KSS-Aerosolen", NameEN: "Inhalation of coolant aerosols",
|
|
RequiredComponentTags: []string{},
|
|
GeneratedHazardCats: []string{"material_environmental"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
Priority: 97, MachineTypes: []string{"cnc", "metalworking", "automotive"},
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "maintenance"},
|
|
ScenarioDE: "Person oeffnet Schutztuer der Bearbeitungszelle und atmet freigesetzte KSS-Aerosole ein.",
|
|
TriggerDE: "Oeffnen der Schutztuer nach Bearbeitungsvorgang, unzureichende Absaugung.",
|
|
HarmDE: "Person atmet KSS-Aerosole ein. Atembeschwerden, Reizung der Atemwege, bei chronischer Exposition Atemwegserkrankungen.",
|
|
AffectedDE: "Bedienpersonal",
|
|
ZoneDE: "Bearbeitungszelle, Bereich vor der Schutztuer",
|
|
DefaultSeverity: 1, DefaultExposure: 3,
|
|
},
|
|
// ================================================================
|
|
// Elektrisch (Roboterzelle-spezifisch)
|
|
// ================================================================
|
|
{
|
|
ID: "HP1640", NameDE: "Direktes Beruehren spannungsfuehrender Teile", NameEN: "Direct contact with live parts",
|
|
RequiredComponentTags: []string{},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"electrical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M481", "M482", "M265", "M139", "M475"},
|
|
Priority: 99,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Person beruehrt spannungsfuehrende Teile der Anlage die nicht ausreichend isoliert oder abgedeckt sind.",
|
|
TriggerDE: "Beschaedigte Isolation, fehlende Abdeckung, ungesicherter Schaltschrank.",
|
|
HarmDE: "Person erleidet elektrischen Schlag. Herzkammerflimmern, Verbrennungen, bei Hochspannung Todesfolge.",
|
|
AffectedDE: "Wartungspersonal, Einrichter",
|
|
ZoneDE: "Zugaengliche Kabel, Klemmen, Schaltschrank",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1641", NameDE: "Gefaehrliche Beruehrungsspannung durch Schutzleiterfehler", NameEN: "Dangerous touch voltage due to PE failure",
|
|
RequiredComponentTags: []string{},
|
|
RequiredEnergyTags: []string{"electrical"},
|
|
GeneratedHazardCats: []string{"electrical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M511", "M512", "M514", "M515", "M475"},
|
|
Priority: 98,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "maintenance", "fault_clearing"},
|
|
ScenarioDE: "Schutzleiter ist unterbrochen. Person beruehrt das Maschinengehaeuse und erleidet elektrischen Schlag durch gefaehrliche Beruehrungsspannung.",
|
|
TriggerDE: "Schutzleiterunterbrechung durch mechanische Beschaedigung oder fehlerhafte Installation.",
|
|
HarmDE: "Elektrischer Schlag bei Beruehren des Maschinengehaeuses oder leitfaehiger Oberflaechen.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal",
|
|
ZoneDE: "Beruehrbare leitfaehige Oberflaechen der Anlage",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1642", NameDE: "Kabelbrand durch Ueberlast oder Kurzschluss", NameEN: "Cable fire from overload or short circuit",
|
|
RequiredComponentTags: []string{},
|
|
RequiredEnergyTags: []string{"electrical"},
|
|
GeneratedHazardCats: []string{"electrical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M009"},
|
|
Priority: 98,
|
|
ApplicableLifecycles: []string{"normal_operation", "setup", "maintenance"},
|
|
ScenarioDE: "Kabel ueberhitzt und entzuendet sich durch Ueberlast oder fehlenden Ueberstromschutz. Person wird durch Brand oder toxische Gase verletzt.",
|
|
TriggerDE: "Dauerhafter Betrieb nahe der Belastungsgrenze, falsch dimensionierte Sicherung.",
|
|
HarmDE: "Brand, Rauchentwicklung, Verletzung durch Feuer oder toxische Gase.",
|
|
AffectedDE: "Alle Personen im Bereich der Anlage",
|
|
ZoneDE: "Kabel und Leitungen der Anlage",
|
|