Benjamin Admin d9d04deb00 feat(ai-sdk): close the 4 GT #3 recall gaps — backflow, cut, restart, spray-arm
CI / detect-changes (push) Successful in 6s
CI / branch-name (push) Has been skipped
CI / guardrail-integrity (push) Has been skipped
CI / secret-scan (push) Has been skipped
CI / dep-audit (push) Has been skipped
CI / sbom-scan (push) Has been skipped
CI / build-sha-integrity (push) Successful in 5s
CI / validate-canonical-controls (push) Successful in 4s
CI / loc-budget (push) Successful in 17s
CI / go-lint (push) Has been skipped
CI / python-lint (push) Has been skipped
CI / nodejs-lint (push) Has been skipped
CI / nodejs-build (push) Has been skipped
CI / test-go (push) Successful in 58s
CI / iace-gt-coverage (push) Successful in 14s
CI / test-python-backend (push) Has been skipped
CI / test-python-document-crawler (push) Has been skipped
CI / test-python-dsms-gateway (push) Has been skipped
Phase 1 complete. GT #3 recall 84% -> 100% (25/25 matched), no regression:
- HP2207 backflow / potable-water contamination (EN 1717) + measure M2209
  (Rueckflussverhinderer / Systemtrenner) — the only genuinely new hazard.
- HP2208 cut on sharp edges/screens (new sharp_edge tag from scharfe-Kante/Sieb).
- HP2209 unexpected restart during maintenance (dedicated dom_warewashing pattern;
  avoids flooding the log via the broad moving_part tag).
- Spray-arm contact now covered by the enclosure-re-scoped contact patterns.

Kistenhub 97.1% and Bremse pinned mappings unchanged; 0/28 hazards without a
measure. Completes the commercial-dishwasher (white-goods Phase 1) coverage.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-25 00:05:30 +02:00
Benjamin Admin a6f1020b2c feat(ai-sdk): IACE warewashing hazard patterns + cross-domain gating
Add commercial-dishwasher hazard patterns (HP2200-HP2206): hot-water/steam
scald on door opening, hot surfaces, hot ware, corrosive detergent/rinse-aid
burn, respiratory irritation, door pinch and wet-floor slip — each gated by
dom_warewashing so they never leak into other machine classes. Add the
matching warewashing protective measures (M2200-M2208).

Tighten capability-domain gating: emit dom_flame/dom_glue and add welding
surface-form gate terms (schweissarbeitsplatz, schweissfunke, lichtbogenzone,
...) so the welding/flame/glue burn patterns stop leaking into thermal-capable
machines such as a dishwasher.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-06-24 20:20:15 +02:00