feat(ai-sdk): close the 4 GT #3 recall gaps — backflow, cut, restart, spray-arm
CI / detect-changes (push) Successful in 6s
CI / branch-name (push) Has been skipped
CI / guardrail-integrity (push) Has been skipped
CI / secret-scan (push) Has been skipped
CI / dep-audit (push) Has been skipped
CI / sbom-scan (push) Has been skipped
CI / build-sha-integrity (push) Successful in 5s
CI / validate-canonical-controls (push) Successful in 4s
CI / loc-budget (push) Successful in 17s
CI / go-lint (push) Has been skipped
CI / python-lint (push) Has been skipped
CI / nodejs-lint (push) Has been skipped
CI / nodejs-build (push) Has been skipped
CI / test-go (push) Successful in 58s
CI / iace-gt-coverage (push) Successful in 14s
CI / test-python-backend (push) Has been skipped
CI / test-python-document-crawler (push) Has been skipped
CI / test-python-dsms-gateway (push) Has been skipped

Phase 1 complete. GT #3 recall 84% -> 100% (25/25 matched), no regression:
- HP2207 backflow / potable-water contamination (EN 1717) + measure M2209
  (Rueckflussverhinderer / Systemtrenner) — the only genuinely new hazard.
- HP2208 cut on sharp edges/screens (new sharp_edge tag from scharfe-Kante/Sieb).
- HP2209 unexpected restart during maintenance (dedicated dom_warewashing pattern;
  avoids flooding the log via the broad moving_part tag).
- Spray-arm contact now covered by the enclosure-re-scoped contact patterns.

Kistenhub 97.1% and Bremse pinned mappings unchanged; 0/28 hazards without a
measure. Completes the commercial-dishwasher (white-goods Phase 1) coverage.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
Benjamin Admin
2026-06-25 00:05:30 +02:00
parent fe5dc59152
commit d9d04deb00
3 changed files with 55 additions and 0 deletions
@@ -128,5 +128,51 @@ func GetWarewashingPatterns() []HazardPattern {
ISO12100Section: "6.3.5.6",
DefaultSeverity: 2, DefaultExposure: 3,
},
{
ID: "HP2207", NameDE: "Rueckfluss / Kontamination des Trinkwassers", NameEN: "Backflow / potable-water contamination",
RequiredComponentTags: []string{"dom_warewashing", "backflow_risk"},
GeneratedHazardCats: []string{"material_environmental"},
SuggestedMeasureIDs: []string{"M2209"},
Priority: 84,
ApplicableLifecycles: []string{"normal_operation"},
ScenarioDE: "Verschmutztes Spuel- oder Chemiewasser wird ueber den Frischwasseranschluss in das Trinkwassernetz zurueckgesaugt und kontaminiert es (Ruecksaugen bei Unterdruck im Netz).",
TriggerDE: "Fehlender oder defekter Rueckflussverhinderer/Systemtrenner; Unterdruck im Trinkwassernetz; kein freier Auslauf.",
HarmDE: "Gesundheitsgefaehrdung Dritter durch kontaminiertes Trinkwasser (Chemie, Keime).",
AffectedDE: "Verbraucher am selben Trinkwassernetz, Betreiber",
ZoneDE: "Frischwasseranschluss, Wasserzulauf",
ISO12100Section: "6.2.4",
DefaultSeverity: 3, DefaultExposure: 2,
},
{
ID: "HP2208", NameDE: "Schnittverletzung an scharfen Kanten/Sieben", NameEN: "Cut injury on sharp edges/screens",
RequiredComponentTags: []string{"dom_warewashing", "sharp_edge"},
GeneratedHazardCats: []string{"mechanical_hazard"},
SuggestedMeasureIDs: []string{"M003"},
Priority: 74,
ApplicableLifecycles: []string{"cleaning", "maintenance"},
ScenarioDE: "Schneiden an scharfen Blechkanten, Sieben oder dem Ablaufpumpen-Laufrad beim Reinigen oder Eingreifen in die Spuelkammer.",
TriggerDE: "Entnehmen/Reinigen der Siebe; Eingreifen an scharfen Kanten ohne Schutzhandschuhe.",
HarmDE: "Schnittwunden an Haenden und Fingern.",
AffectedDE: "Reinigungspersonal, Bedienpersonal",
ZoneDE: "Zugaengliche Kanten, Siebe, Spuelkammer, Ablaufpumpe",
ISO12100Section: "6.2.2.1",
DefaultSeverity: 1, DefaultExposure: 3,
},
{
ID: "HP2209", NameDE: "Unerwarteter Wiederanlauf bei Wartung/Reinigung", NameEN: "Unexpected restart during maintenance/cleaning",
RequiredComponentTags: []string{"dom_warewashing", "programmable"},
RequiredLifecycles: []string{"maintenance", "cleaning", "fault_clearing"},
GeneratedHazardCats: []string{"safety_function_failure"},
SuggestedMeasureIDs: []string{"M042"},
Priority: 80,
ApplicableLifecycles: []string{"maintenance", "cleaning"},
ScenarioDE: "Waehrend Wartung oder Reinigung laeuft die Maschine durch fehlende Freischaltung (LOTO) oder automatischen Wiederanlauf unerwartet an (Pumpe, Spuelgang).",
TriggerDE: "Kein Freischalten/Sichern gegen Wiedereinschalten; automatischer Wiederanlauf nach Netzunterbrechung.",
HarmDE: "Verbruehung, Quetschen oder elektrischer Schlag durch unerwartet anlaufende Maschine.",
AffectedDE: "Wartungspersonal, Reinigungspersonal",
ZoneDE: "Gesamte Maschine, Pumpe, Antriebe",
ISO12100Section: "6.2.11.4",
DefaultSeverity: 3, DefaultExposure: 2,
},
}
}
@@ -107,6 +107,9 @@ func GetKeywordDictionary() []KeywordEntry {
// honest (generic hygiene; surfaced by the warewashing GT).
{Keywords: []string{"spuelarm", "spuelfeld", "wascharm", "spruehfeld"}, ExtraTags: []string{"rotating_part"}},
{Keywords: []string{"spuelkammer", "spueltuer", "geraetetuer", "haubentuer", "klapptuer"}, ExtraTags: []string{"access_door"}},
// Frischwasseranschluss an das Trinkwassernetz -> Rueckfluss/Ruecksaug-Risiko (EN 1717).
{Keywords: []string{"rueckfluss", "rueckflussverhinderer", "ruecksaug", "trinkwasser", "frischwasseranschluss", "systemtrenner"}, ExtraTags: []string{"backflow_risk"}},
{Keywords: []string{"scharfe kante", "scharfkant", "blechkante", "scharfe blechkante", "sieb", "siebe"}, ExtraTags: []string{"sharp_edge"}},
// Ghost-Closure (Emit-Seite): macht die 34 toten Required-Tags
// emittierbar, jeweils NUR via domaenenspezifische Keywords -> die 120
// Ghost-Patterns feuern wieder, aber nur fuer ihre echte Maschine (kein
@@ -65,5 +65,11 @@ func getWarewashingMeasures() []ProtectiveMeasureEntry {
HazardCategory: "general",
Examples: []string{"Warnpiktogramm 'Heisser Dampf' an der Tuer", "BA-Hinweis 'Tuer nach Programmende langsam oeffnen'"},
NormReferences: []string{"ISO 7010", "EN 60335-2-58"}},
{ID: "M2209", ReductionType: "design", SubType: "containment",
Name: "Rueckflussverhinderer / Systemtrenner nach EN 1717",
Description: "Der Frischwasseranschluss ist durch einen Rueckflussverhinderer bzw. Systemtrenner der passenden Schutzklasse oder durch einen freien Auslauf gegen Ruecksaugen verschmutzten Wassers in das Trinkwassernetz gesichert.",
HazardCategory: "material_environmental",
Examples: []string{"Systemtrenner Typ BA nach EN 1717", "Freier Auslauf Typ AB ueber dem hoechsten Wasserstand"},
NormReferences: []string{"EN 1717", "EN 60335-2-58"}},
}
}