feat(ai-sdk): close the 4 GT #3 recall gaps — backflow, cut, restart, spray-arm
CI / detect-changes (push) Successful in 6s
CI / branch-name (push) Has been skipped
CI / guardrail-integrity (push) Has been skipped
CI / secret-scan (push) Has been skipped
CI / dep-audit (push) Has been skipped
CI / sbom-scan (push) Has been skipped
CI / build-sha-integrity (push) Successful in 5s
CI / validate-canonical-controls (push) Successful in 4s
CI / loc-budget (push) Successful in 17s
CI / go-lint (push) Has been skipped
CI / python-lint (push) Has been skipped
CI / nodejs-lint (push) Has been skipped
CI / nodejs-build (push) Has been skipped
CI / test-go (push) Successful in 58s
CI / iace-gt-coverage (push) Successful in 14s
CI / test-python-backend (push) Has been skipped
CI / test-python-document-crawler (push) Has been skipped
CI / test-python-dsms-gateway (push) Has been skipped

Phase 1 complete. GT #3 recall 84% -> 100% (25/25 matched), no regression:
- HP2207 backflow / potable-water contamination (EN 1717) + measure M2209
  (Rueckflussverhinderer / Systemtrenner) — the only genuinely new hazard.
- HP2208 cut on sharp edges/screens (new sharp_edge tag from scharfe-Kante/Sieb).
- HP2209 unexpected restart during maintenance (dedicated dom_warewashing pattern;
  avoids flooding the log via the broad moving_part tag).
- Spray-arm contact now covered by the enclosure-re-scoped contact patterns.

Kistenhub 97.1% and Bremse pinned mappings unchanged; 0/28 hazards without a
measure. Completes the commercial-dishwasher (white-goods Phase 1) coverage.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
Benjamin Admin
2026-06-25 00:05:30 +02:00
parent fe5dc59152
commit d9d04deb00
3 changed files with 55 additions and 0 deletions
@@ -65,5 +65,11 @@ func getWarewashingMeasures() []ProtectiveMeasureEntry {
HazardCategory: "general",
Examples: []string{"Warnpiktogramm 'Heisser Dampf' an der Tuer", "BA-Hinweis 'Tuer nach Programmende langsam oeffnen'"},
NormReferences: []string{"ISO 7010", "EN 60335-2-58"}},
{ID: "M2209", ReductionType: "design", SubType: "containment",
Name: "Rueckflussverhinderer / Systemtrenner nach EN 1717",
Description: "Der Frischwasseranschluss ist durch einen Rueckflussverhinderer bzw. Systemtrenner der passenden Schutzklasse oder durch einen freien Auslauf gegen Ruecksaugen verschmutzten Wassers in das Trinkwassernetz gesichert.",
HazardCategory: "material_environmental",
Examples: []string{"Systemtrenner Typ BA nach EN 1717", "Freier Auslauf Typ AB ueber dem hoechsten Wasserstand"},
NormReferences: []string{"EN 1717", "EN 60335-2-58"}},
}
}