feat(matrix): PlcSps composite device target (SBOM/CVE/DAST/pentest) (#168)
CI / Check (push) Has been skipped
CI / Detect Changes (push) Successful in 4s
CI / Deploy Agent (push) Successful in 3m51s
CI / Deploy Dashboard (push) Successful in 3m1s
CI / Deploy Docs (push) Has been skipped
CI / Deploy MCP (push) Successful in 2m9s

This commit was merged in pull request #168.
This commit is contained in:
2026-07-16 10:56:36 +00:00
parent afa5c985ee
commit 3a53a1d7f2
2 changed files with 118 additions and 22 deletions
+18 -11
View File
@@ -450,37 +450,44 @@ impl PipelineOrchestrator {
self.ensure_dast_target(target, &plan).await;
// PLC control-logic analysis for PLC/SPS targets (a PlcProject artifact).
// A PLC/SPS device is a composite target: after the control-logic scan we
// fall through so a reachable device (WebVisu / exposed services) still
// gets DAST, rather than early-returning on the PLC scan alone.
let mut new_count = 0u32;
if plan.has(ScanType::PlcControlLogic) {
return self.run_plc_scan(target, &target_id, scan_run_id).await;
new_count += self.run_plc_scan(target, &target_id, scan_run_id).await?;
}
match target.code_artifact() {
Some(code) if code.kind == ArtifactKind::GitRepo => {
let repo = RepoView::from_target(target, code);
let new_count = self.run_pipeline(&repo, scan_run_id).await?;
self.finalize_target(target, &repo, new_count).await?;
Ok(new_count)
let n = {
let repo = RepoView::from_target(target, code);
let n = self.run_pipeline(&repo, scan_run_id).await?;
self.finalize_target(target, &repo, n).await?;
n
};
new_count += n;
}
Some(_) => {
tracing::warn!(
target_id = %target_id,
"Unified pipeline: source-archive scanning not yet wired; skipping"
);
Ok(0)
}
None => {
// No code to scan. Firmware/PLC/mobile static scanners land in
// #128/#129/#130; DAST for a running URL still works when a
// DastTarget row exists (migrated targets).
// No code to scan (a PLC device or a migrated DAST target).
// Firmware/mobile static scanners land in #128/#129; DAST for a
// running URL works when a DastTarget row exists (provisioned above
// from a LiveUrl, or from a migrated target).
tracing::info!(
target_id = %target_id,
"Unified pipeline: no code artifact; attempting DAST only"
"Unified pipeline: no code artifact; attempting DAST"
);
self.update_phase(scan_run_id, "dast_scanning").await;
self.maybe_trigger_dast(&target_id, scan_run_id).await;
Ok(0)
}
}
Ok(new_count)
}
/// Analyze a PLC/SPS project (Structured Text / PLCopen XML) for
+100 -11
View File
@@ -207,12 +207,52 @@ pub fn rules_for(target_type: TargetType) -> Vec<ScanRule> {
));
r
}
TargetType::PlcSps => vec![ScanRule::new(
ScanType::PlcControlLogic,
true,
"Control-logic security rules over the PLC program",
Plc,
)],
TargetType::PlcSps => {
// A PLC/SPS device is a composite: the control application *and* the
// device it runs on (firmware/OS + reachable runtime services). The
// control-logic scan runs on the PLC project; the firmware and DAST
// scans light up only when a firmware image / running endpoint is
// attached (e.g. a CODESYS runtime on a Yocto image with WebVisu).
// Firmware-image SBOM/CVE *execution* is shared with the firmware
// families and tracked in #151/#128; DAST over a WebVisu/OPC-UA
// endpoint uses the existing DAST path.
vec![
ScanRule::new(
ScanType::PlcControlLogic,
true,
"Control-logic security rules over the PLC program",
Plc,
),
// Device-level scans are offered but opt-in (default-off): they
// apply only when a firmware image is attached, and firmware-image
// SBOM/CVE *execution* is shared with the firmware families and
// still landing (#151/#128), so they must not silently auto-run.
ScanRule::new(
ScanType::FirmwareStatic,
false,
"Static analysis of the device firmware image (OS + runtime)",
Firmware,
),
ScanRule::new(
ScanType::Sbom,
false,
"SBOM from the device firmware image (OS packages + CODESYS runtime)",
Firmware,
),
ScanRule::new(
ScanType::Cve,
false,
"Match device firmware components against known CVEs",
Firmware,
),
ScanRule::new(
ScanType::Dast,
false,
"Dynamic scan of the running device (WebVisu / exposed services)",
RunningUrl,
),
]
}
}
}
@@ -229,6 +269,9 @@ pub fn supports_pentest(target_type: TargetType) -> bool {
| TargetType::AndroidApp
| TargetType::IosApp
| TargetType::EmbeddedLinuxYocto
// A PLC/SPS device exposes reachable runtime services (WebVisu, OPC UA,
// the CODESYS programming protocol), so an active pentest applies.
| TargetType::PlcSps
)
}
@@ -340,22 +383,68 @@ mod tests {
}
#[test]
fn plc_offers_only_control_logic() {
fn plc_control_logic_is_default_on_and_device_scans_block_without_artifacts() {
// A PLC project alone: control-logic runs; the device-level scans are
// offered but blocked until a firmware image / running endpoint is added.
let t = target_with(
TargetType::PlcSps,
vec![Artifact::plc_project("p.xml", PlcFormat::PlcopenXml)],
);
let opts = applicable_scans(&t);
assert_eq!(opts.len(), 1);
assert_eq!(opts[0].scan, ScanType::PlcControlLogic);
assert!(opts[0].default_on);
let plc = option(&opts, ScanType::PlcControlLogic).expect("control-logic offered");
assert!(plc.default_on && plc.blocked_reason.is_none());
for scan in [ScanType::FirmwareStatic, ScanType::Sbom, ScanType::Cve] {
let o = option(&opts, scan).expect("device scan offered");
assert!(
!o.default_on,
"{scan} must not pre-select without a firmware image"
);
assert!(o.blocked_reason.is_some());
}
let dast = option(&opts, ScanType::Dast).expect("dast offered");
assert!(!dast.default_on);
assert!(dast.blocked_reason.is_some());
}
#[test]
fn plc_composite_lights_up_device_scans_with_firmware_and_url() {
// A CODESYS-on-Yocto device: PLC project + firmware image + WebVisu URL.
let t = target_with(
TargetType::PlcSps,
vec![
Artifact::plc_project("p.xml", PlcFormat::PlcopenXml),
Artifact::firmware_image("device.img"),
Artifact::live_url("http://plc.local/webvisu"),
],
);
let opts = applicable_scans(&t);
for scan in [
ScanType::PlcControlLogic,
ScanType::FirmwareStatic,
ScanType::Sbom,
ScanType::Cve,
] {
let o = option(&opts, scan).expect("scan offered");
assert!(o.blocked_reason.is_none(), "{scan} should be unblocked");
}
// Control-logic auto-runs; the device-level scans are unblocked but opt-in
// (default-off) until firmware-image execution lands (#151/#128).
assert!(option(&opts, ScanType::PlcControlLogic).unwrap().default_on);
assert!(!option(&opts, ScanType::Sbom).unwrap().default_on);
assert!(!option(&opts, ScanType::Dast).unwrap().default_on);
assert!(option(&opts, ScanType::Dast)
.unwrap()
.blocked_reason
.is_none());
}
#[test]
fn pentest_support_matches_reachable_families() {
assert!(supports_pentest(TargetType::WebApp));
assert!(supports_pentest(TargetType::BackendService));
assert!(!supports_pentest(TargetType::PlcSps));
assert!(supports_pentest(TargetType::EmbeddedLinuxYocto));
// A PLC/SPS device is network-reachable (WebVisu / OPC UA / 11740).
assert!(supports_pentest(TargetType::PlcSps));
assert!(!supports_pentest(TargetType::FirmwareBareMetal));
assert!(!supports_pentest(TargetType::DesktopApp));
}