Files
breakpilot-compliance/ai-compliance-sdk/internal/iace/hazard_patterns_electrical.go
T
Benjamin Admin e7f2f98da3 feat: IACE CE-Compliance Module — Normen, Risikobewertung, Production Lines
Major features:
- 215 norms library with section references + Beuth URLs (A/B1/B2/C norms)
- 173 hazard patterns with detail fields (scenario, trigger, harm, zone)
- Deterministic pattern matching: Component × Lifecycle × Pattern cross-product
- SIL/PL auto-calculation from S×E×P risk graph
- Risk assessment table with editable S/E/P dropdowns
- Production Line Dashboard with animated station flow (Running Dots)
- IACE process flow + norms coverage on start page
- Non-blocking cookie banner, ProcessFlow SSR fix
- 104 Playwright E2E tests passing

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-05-07 10:53:26 +02:00

83 lines
4.9 KiB
Go

package iace
// builtinElectricalPatterns returns HP011-HP015: electrical hazard patterns.
func builtinElectricalPatterns() []HazardPattern {
return []HazardPattern{
{
ID: "HP011", NameDE: "Stromschlaggefahr durch Hochspannung", NameEN: "Electric shock risk from high voltage",
RequiredComponentTags: []string{"high_voltage"},
RequiredEnergyTags: []string{"electrical_energy"},
GeneratedHazardCats: []string{"electrical_hazard"},
SuggestedMeasureIDs: []string{"M061", "M062", "M063", "M121"},
SuggestedEvidenceIDs: []string{"E01", "E04", "E10"},
Priority: 95,
ScenarioDE: "Person beruehrt spannungsfuehrende Teile bei Wartung, Stoerungsbeseitigung oder durch defekte Isolation.",
TriggerDE: "Direktes oder indirektes Beruehren spannungsfuehrender Leiter ueber 50 V AC / 120 V DC.",
HarmDE: "Stromschlag, Herzkammerflimmern, Verbrennungen, Todesfolge bei Hochspannung.",
AffectedDE: "Wartungspersonal, Elektrofachkraefte, Bedienpersonal",
ZoneDE: "Schaltschrank, Klemmenkasten, Motoranschluss, Frequenzumrichter",
DefaultSeverity: 5, DefaultExposure: 2,
},
{
ID: "HP012", NameDE: "Gefahr durch elektrische Komponenten", NameEN: "Risk from electrical components",
RequiredComponentTags: []string{"electrical_part"},
RequiredEnergyTags: []string{"electrical_energy"},
GeneratedHazardCats: []string{"electrical_hazard"},
SuggestedMeasureIDs: []string{"M061", "M064", "M121"},
SuggestedEvidenceIDs: []string{"E01", "E04", "E10"},
Priority: 85,
ScenarioDE: "Elektrische Bauteile (Motoren, Netzteile, Schaltgeraete) stellen bei Defekt oder offenem Gehaeuse eine Beruehrungsgefahr dar.",
TriggerDE: "Isolationsfehler, offene Gehaeuse oder beschaedigte Leitungen fuehren zu Spannungsverschleppung.",
HarmDE: "Stromschlag, lokale Verbrennungen, Muskelverkrampfung.",
AffectedDE: "Bedienpersonal, Wartungspersonal",
ZoneDE: "Motorgehaeuse, Anschlussklemmen, Netzteile, Kabelkanaele",
DefaultSeverity: 4, DefaultExposure: 2,
},
{
ID: "HP013", NameDE: "Gefahr durch gespeicherte elektrische Energie", NameEN: "Stored electrical energy risk",
RequiredComponentTags: []string{"stored_energy"},
RequiredEnergyTags: []string{"electrical_energy"},
GeneratedHazardCats: []string{"electrical_hazard"},
SuggestedMeasureIDs: []string{"M062", "M063", "M121", "M123"},
SuggestedEvidenceIDs: []string{"E01", "E10"},
Priority: 85,
ScenarioDE: "Kondensatoren, Batterien oder Frequenzumrichter halten nach Abschalten gefaehrliche Restspannung.",
TriggerDE: "Wartungsarbeiten am Geraet ohne Warten der Entladezeit oder ohne Spannungsfreiheitspruefung.",
HarmDE: "Stromschlag, Verbrennungen durch Lichtbogen, Explosion bei Lithium-Akkus.",
AffectedDE: "Elektrofachkraefte, Wartungspersonal",
ZoneDE: "Zwischenkreiskondensatoren, Batteriefaecher, USV-Anlagen",
DefaultSeverity: 4, DefaultExposure: 2,
},
{
ID: "HP014", NameDE: "Kurzschluss-/Lichtbogengefahr", NameEN: "Short circuit / arc flash risk",
RequiredComponentTags: []string{"high_voltage", "electrical_part"},
RequiredEnergyTags: []string{},
GeneratedHazardCats: []string{"electrical_hazard", "thermal_hazard"},
SuggestedMeasureIDs: []string{"M061", "M065", "M131"},
SuggestedEvidenceIDs: []string{"E01", "E04", "E10"},
Priority: 90,
ScenarioDE: "Kurzschluss erzeugt Lichtbogen mit extremer Hitze und Druckwelle im Schaltschrank.",
TriggerDE: "Werkzeug ueberbrueckt spannungsfuehrende Teile, Isolationsversagen oder Verschmutzung unter Spannung.",
HarmDE: "Schwere Verbrennungen (2./3. Grad), Augenverletzung durch UV-Strahlung, Hoerschaden durch Druckwelle.",
AffectedDE: "Elektrofachkraefte, Personen in unmittelbarer Naehe",
ZoneDE: "Schaltschrank-Innenraum, Sammelschienen, Leistungsschuetze",
DefaultSeverity: 5, DefaultExposure: 2,
},
{
ID: "HP015", NameDE: "EMV-Stoerungsgefahr", NameEN: "EMC interference risk",
RequiredComponentTags: []string{"electrical_part"},
RequiredEnergyTags: []string{"electromagnetic"},
GeneratedHazardCats: []string{"emc_hazard"},
SuggestedMeasureIDs: []string{"M066", "M121"},
SuggestedEvidenceIDs: []string{"E01", "E10"},
Priority: 70,
ScenarioDE: "Elektromagnetische Stoerungen beeinflussen Steuerungssignale und loesen unerwartete Maschinenbewegungen aus.",
TriggerDE: "Nahes Hochfrequenzgeraet, mangelnde Schirmung oder fehlende Filterung stoert Steuersignale.",
HarmDE: "Fehlausloesung von Aktoren, unerwartete Bewegung, Ausfall von Sicherheitsfunktionen.",
AffectedDE: "Bedienpersonal, Personen im Maschinenbereich",
ZoneDE: "Gesamte Maschinenumgebung, insbesondere Signalleitungen und Sensorik",
DefaultSeverity: 3, DefaultExposure: 2,
},
}
}