- Hazard-Library: +79 neue Eintraege in 12 Kategorien (software_fault,
  hmi_error, mechanical_hazard, electrical_hazard, thermal_hazard,
  emc_hazard, configuration_error, safety_function_failure,
  logging_audit_failure, integration_error, environmental_hazard,
  maintenance_hazard) — Gesamtanzahl: ~116 Eintraege in 24 Kategorien
- Controls-Library: neue Datei controls_library.go mit 200 Eintraegen
  in 6 Domaenen (REQ/ARCH/SWDEV/VER/CYBER/DOC)
- Handler: GET /sdk/v1/iace/controls-library (?domain=, ?category=)
- SEPA: CalculateInherentRisk() + 4. Param Avoidance (0=disabled,
  1-5: 3=neutral); RiskComputeInput.Avoidance, RiskAssessment.Avoidance,
  AssessRiskRequest.Avoidance — backward-kompatibel (A=0 → S×E×P)
- Tests: engine_test.go + hazard_library_test.go aktualisiert
- Scripts: ingest-ce-corpus.sh — 15 CE/Safety-Dokumente (EUR-Lex,
  NIST, ENISA, NASA, OWASP, MITRE CWE) in bp_compliance_ce und
  bp_compliance_datenschutz
- Docs: docs-src/services/sdk-modules/iace.md + mkdocs.yml Nav-Eintrag

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-05 17:13:01 +01:00

1769 lines
96 KiB
Go

package iace
import (
"encoding/json"
"fmt"
"time"
"github.com/google/uuid"
)
// hazardUUID generates a deterministic UUID for a hazard library entry
// based on category and a 1-based index within that category.
func hazardUUID(category string, index int) uuid.UUID {
name := fmt.Sprintf("iace.hazard.%s.%d", category, index)
return uuid.NewSHA1(uuid.NameSpaceDNS, []byte(name))
}
// mustMarshalJSON marshals the given value to json.RawMessage, panicking on error.
// This is safe to use for static data known at compile time.
func mustMarshalJSON(v interface{}) json.RawMessage {
data, err := json.Marshal(v)
if err != nil {
panic(fmt.Sprintf("hazard_library: failed to marshal JSON: %v", err))
}
return data
}
// GetBuiltinHazardLibrary returns the complete built-in hazard library with 40+
// template entries for SW/FW/KI hazards in industrial machines. These entries are
// intended to be seeded into the iace_hazard_library table during initial setup.
//
// All entries have IsBuiltin=true and TenantID=nil (system-level templates).
// UUIDs are deterministic, generated via uuid.NewSHA1 based on category and index.
func GetBuiltinHazardLibrary() []HazardLibraryEntry {
now := time.Now()
entries := []HazardLibraryEntry{
// ====================================================================
// Category: false_classification (4 entries)
// ====================================================================
{
ID: hazardUUID("false_classification", 1),
Category: "false_classification",
Name: "Falsche Bauteil-Klassifikation durch KI",
Description: "Das KI-Modell klassifiziert ein Bauteil fehlerhaft, was zu falscher Weiterverarbeitung oder Montage fuehren kann.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"ai_model", "sensor"},
RegulationReferences: []string{"EU AI Act Art. 9", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Redundante Pruefung", "Konfidenz-Schwellwert"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("false_classification", 2),
Category: "false_classification",
Name: "Falsche Qualitaetsentscheidung (IO/NIO)",
Description: "Fehlerhafte IO/NIO-Entscheidung durch das KI-System fuehrt dazu, dass defekte Teile als gut bewertet oder gute Teile verworfen werden.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"ai_model", "software"},
RegulationReferences: []string{"EU AI Act Art. 9", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Human-in-the-Loop", "Stichproben-Gegenpruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("false_classification", 3),
Category: "false_classification",
Name: "Fehlklassifikation bei Grenzwertfaellen",
Description: "Bauteile nahe an Toleranzgrenzen werden systematisch falsch klassifiziert, da das Modell in Grenzwertbereichen unsicher agiert.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"ai_model"},
RegulationReferences: []string{"EU AI Act Art. 9", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Erweitertes Training", "Grauzone-Eskalation"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("false_classification", 4),
Category: "false_classification",
Name: "Verwechslung von Bauteiltypen",
Description: "Unterschiedliche Bauteiltypen werden vom KI-Modell verwechselt, was zu falscher Montage oder Verarbeitung fuehrt.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"ai_model", "sensor"},
RegulationReferences: []string{"EU AI Act Art. 9", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Barcode-Gegenpruefung", "Doppelte Sensorik"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: timing_error (3 entries)
// ====================================================================
{
ID: hazardUUID("timing_error", 1),
Category: "timing_error",
Name: "Verzoegerte KI-Reaktion in Echtzeitsystem",
Description: "Die KI-Inferenz dauert laenger als die zulaessige Echtzeitfrist, was zu verspaeteten Sicherheitsreaktionen fuehrt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "ai_model"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Watchdog-Timer", "Fallback-Steuerung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("timing_error", 2),
Category: "timing_error",
Name: "Echtzeit-Verletzung Safety-Loop",
Description: "Der sicherheitsgerichtete Regelkreis kann die geforderten Zykluszeiten nicht einhalten, wodurch Sicherheitsfunktionen versagen koennen.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"ISO 13849", "IEC 61508", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Deterministische Ausfuehrung", "WCET-Analyse"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("timing_error", 3),
Category: "timing_error",
Name: "Timing-Jitter bei Netzwerkkommunikation",
Description: "Schwankende Netzwerklatenzen fuehren zu unvorhersehbaren Verzoegerungen in der Datenuebertragung sicherheitsrelevanter Signale.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"network", "software"},
RegulationReferences: []string{"IEC 62443", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"TSN-Netzwerk", "Pufferung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: data_poisoning (2 entries)
// ====================================================================
{
ID: hazardUUID("data_poisoning", 1),
Category: "data_poisoning",
Name: "Manipulierte Trainingsdaten",
Description: "Trainingsdaten werden absichtlich oder unbeabsichtigt manipuliert, wodurch das Modell systematisch fehlerhafte Entscheidungen trifft.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"ai_model"},
RegulationReferences: []string{"EU AI Act Art. 10", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"Daten-Validierung", "Anomalie-Erkennung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("data_poisoning", 2),
Category: "data_poisoning",
Name: "Adversarial Input Angriff",
Description: "Gezielte Manipulation von Eingabedaten (z.B. Bilder, Sensorsignale), um das KI-Modell zu taeuschen und Fehlentscheidungen auszuloesen.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"ai_model", "sensor"},
RegulationReferences: []string{"EU AI Act Art. 15", "CRA", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Input-Validation", "Adversarial Training"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: model_drift (3 entries)
// ====================================================================
{
ID: hazardUUID("model_drift", 1),
Category: "model_drift",
Name: "Performance-Degradation durch Concept Drift",
Description: "Die statistische Verteilung der Eingabedaten aendert sich ueber die Zeit, wodurch die Modellgenauigkeit schleichend abnimmt.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"ai_model"},
RegulationReferences: []string{"EU AI Act Art. 9", "EU AI Act Art. 72"},
SuggestedMitigations: mustMarshalJSON([]string{"Monitoring-Dashboard", "Automatisches Retraining"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("model_drift", 2),
Category: "model_drift",
Name: "Data Drift durch veraenderte Umgebung",
Description: "Aenderungen in der physischen Umgebung (Beleuchtung, Temperatur, Material) fuehren zu veraenderten Sensordaten und Modellfehlern.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"ai_model", "sensor"},
RegulationReferences: []string{"EU AI Act Art. 9", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Statistische Ueberwachung", "Sensor-Kalibrierung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("model_drift", 3),
Category: "model_drift",
Name: "Schleichende Modell-Verschlechterung",
Description: "Ohne aktives Monitoring verschlechtert sich die Modellqualitaet ueber Wochen oder Monate unbemerkt.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"ai_model"},
RegulationReferences: []string{"EU AI Act Art. 9", "EU AI Act Art. 72"},
SuggestedMitigations: mustMarshalJSON([]string{"Regelmaessige Evaluierung", "A/B-Testing"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: sensor_spoofing (3 entries)
// ====================================================================
{
ID: hazardUUID("sensor_spoofing", 1),
Category: "sensor_spoofing",
Name: "Kamera-Manipulation / Abdeckung",
Description: "Kamerasensoren werden absichtlich oder unbeabsichtigt abgedeckt oder manipuliert, sodass das System auf Basis falscher Bilddaten agiert.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"sensor"},
RegulationReferences: []string{"IEC 62443", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Plausibilitaetspruefung", "Mehrfach-Sensorik"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("sensor_spoofing", 2),
Category: "sensor_spoofing",
Name: "Sensor-Signal-Injection",
Description: "Einspeisung gefaelschter Signale in die Sensorleitungen oder Schnittstellen, um das System gezielt zu manipulieren.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"sensor", "network"},
RegulationReferences: []string{"IEC 62443", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"Signalverschluesselung", "Anomalie-Erkennung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("sensor_spoofing", 3),
Category: "sensor_spoofing",
Name: "Umgebungsbasierte Sensor-Taeuschung",
Description: "Natuerliche oder kuenstliche Umgebungsveraenderungen (Licht, Staub, Vibration) fuehren zu fehlerhaften Sensorwerten.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"sensor"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Sensor-Fusion", "Redundanz"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: communication_failure (3 entries)
// ====================================================================
{
ID: hazardUUID("communication_failure", 1),
Category: "communication_failure",
Name: "Feldbus-Ausfall",
Description: "Ausfall des industriellen Feldbusses (z.B. PROFINET, EtherCAT) fuehrt zum Verlust der Kommunikation zwischen Steuerung und Aktorik.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"network", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Redundanter Bus", "Safe-State-Transition"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("communication_failure", 2),
Category: "communication_failure",
Name: "Cloud-Verbindungsverlust",
Description: "Die Verbindung zur Cloud-Infrastruktur bricht ab, wodurch cloud-abhaengige Funktionen (z.B. Modell-Updates, Monitoring) nicht verfuegbar sind.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"network", "software"},
RegulationReferences: []string{"CRA", "EU AI Act Art. 15"},
SuggestedMitigations: mustMarshalJSON([]string{"Offline-Faehigkeit", "Edge-Computing"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("communication_failure", 3),
Category: "communication_failure",
Name: "Netzwerk-Latenz-Spitzen",
Description: "Unkontrollierte Latenzspitzen im Netzwerk fuehren zu Timeouts und verspaeteter Datenlieferung an sicherheitsrelevante Systeme.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"network"},
RegulationReferences: []string{"IEC 62443", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"QoS-Konfiguration", "Timeout-Handling"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: unauthorized_access (4 entries)
// ====================================================================
{
ID: hazardUUID("unauthorized_access", 1),
Category: "unauthorized_access",
Name: "Unautorisierter Remote-Zugriff",
Description: "Ein Angreifer erlangt ueber das Netzwerk Zugriff auf die Maschinensteuerung und kann sicherheitsrelevante Parameter aendern.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"network", "software"},
RegulationReferences: []string{"IEC 62443", "CRA", "EU AI Act Art. 15"},
SuggestedMitigations: mustMarshalJSON([]string{"VPN", "MFA", "Netzwerksegmentierung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("unauthorized_access", 2),
Category: "unauthorized_access",
Name: "Konfigurations-Manipulation",
Description: "Sicherheitsrelevante Konfigurationsparameter werden unautorisiert geaendert, z.B. Grenzwerte, Schwellwerte oder Betriebsmodi.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62443", "CRA", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Zugriffskontrolle", "Audit-Log"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("unauthorized_access", 3),
Category: "unauthorized_access",
Name: "Privilege Escalation",
Description: "Ein Benutzer oder Prozess erlangt hoehere Berechtigungen als vorgesehen und kann sicherheitskritische Aktionen ausfuehren.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"software"},
RegulationReferences: []string{"IEC 62443", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"RBAC", "Least Privilege"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("unauthorized_access", 4),
Category: "unauthorized_access",
Name: "Supply-Chain-Angriff auf Komponente",
Description: "Eine kompromittierte Softwarekomponente oder Firmware wird ueber die Lieferkette eingeschleust und enthaelt Schadcode oder Backdoors.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"CRA", "IEC 62443", "EU AI Act Art. 15"},
SuggestedMitigations: mustMarshalJSON([]string{"SBOM", "Signaturpruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: firmware_corruption (3 entries)
// ====================================================================
{
ID: hazardUUID("firmware_corruption", 1),
Category: "firmware_corruption",
Name: "Update-Abbruch mit inkonsistentem Zustand",
Description: "Ein Firmware-Update wird unterbrochen (z.B. Stromausfall), wodurch das System in einem inkonsistenten und potenziell unsicheren Zustand verbleibt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"firmware"},
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"A/B-Partitioning", "Rollback"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("firmware_corruption", 2),
Category: "firmware_corruption",
Name: "Rollback-Fehler auf alte Version",
Description: "Ein Rollback auf eine aeltere Firmware-Version schlaegt fehl oder fuehrt zu Inkompatibilitaeten mit der aktuellen Hardware-/Softwarekonfiguration.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"firmware"},
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Versionsmanagement", "Kompatibilitaetspruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("firmware_corruption", 3),
Category: "firmware_corruption",
Name: "Boot-Chain-Angriff",
Description: "Die Bootsequenz wird manipuliert, um unsignierte oder kompromittierte Firmware auszufuehren, was die gesamte Sicherheitsarchitektur untergaebt.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"firmware"},
RegulationReferences: []string{"CRA", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Secure Boot", "TPM"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: safety_boundary_violation (4 entries)
// ====================================================================
{
ID: hazardUUID("safety_boundary_violation", 1),
Category: "safety_boundary_violation",
Name: "Kraft-/Drehmoment-Ueberschreitung",
Description: "Aktorische Systeme ueberschreiten die zulaessigen Kraft- oder Drehmomentwerte, was zu Verletzungen oder Maschinenschaeden fuehren kann.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "actuator"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Hardware-Limiter", "SIL-Ueberwachung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_boundary_violation", 2),
Category: "safety_boundary_violation",
Name: "Geschwindigkeitsueberschreitung Roboter",
Description: "Ein Industrieroboter ueberschreitet die zulaessige Geschwindigkeit, insbesondere bei Mensch-Roboter-Kollaboration.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "ISO 10218"},
SuggestedMitigations: mustMarshalJSON([]string{"Safe Speed Monitoring", "Lichtgitter"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_boundary_violation", 3),
Category: "safety_boundary_violation",
Name: "Versagen des Safe-State",
Description: "Das System kann im Fehlerfall keinen sicheren Zustand einnehmen, da die Sicherheitssteuerung selbst versagt.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"controller", "software", "firmware"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Redundante Sicherheitssteuerung", "Diverse Programmierung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_boundary_violation", 4),
Category: "safety_boundary_violation",
Name: "Arbeitsraum-Verletzung",
Description: "Ein Roboter oder Aktor verlaesst seinen definierten Arbeitsraum und dringt in den Schutzbereich von Personen ein.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "sensor"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "ISO 10218"},
SuggestedMitigations: mustMarshalJSON([]string{"Sichere Achsueberwachung", "Schutzzaun-Sensorik"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: mode_confusion (3 entries)
// ====================================================================
{
ID: hazardUUID("mode_confusion", 1),
Category: "mode_confusion",
Name: "Falsche Betriebsart aktiv",
Description: "Das System befindet sich in einer unbeabsichtigten Betriebsart (z.B. Automatik statt Einrichtbetrieb), was zu unerwarteten Maschinenbewegungen fuehrt.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"hmi", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Betriebsart-Anzeige", "Schluesselschalter"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mode_confusion", 2),
Category: "mode_confusion",
Name: "Wartung/Normal-Verwechslung",
Description: "Das System wird im Normalbetrieb gewartet oder der Wartungsmodus wird nicht korrekt verlassen, was zu gefaehrlichen Situationen fuehrt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"hmi", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Zugangskontrolle", "Sicherheitsverriegelung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mode_confusion", 3),
Category: "mode_confusion",
Name: "Automatik-Eingriff waehrend Handbetrieb",
Description: "Das System wechselt waehrend des Handbetriebs unerwartet in den Automatikbetrieb, wodurch eine Person im Gefahrenbereich verletzt werden kann.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Exklusive Betriebsarten", "Zustimmtaster"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: unintended_bias (2 entries)
// ====================================================================
{
ID: hazardUUID("unintended_bias", 1),
Category: "unintended_bias",
Name: "Diskriminierende KI-Entscheidung",
Description: "Das KI-Modell trifft systematisch diskriminierende Entscheidungen, z.B. bei der Qualitaetsbewertung bestimmter Produktchargen oder Lieferanten.",
DefaultSeverity: 3,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"ai_model"},
RegulationReferences: []string{"EU AI Act Art. 10", "EU AI Act Art. 71"},
SuggestedMitigations: mustMarshalJSON([]string{"Bias-Testing", "Fairness-Metriken"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("unintended_bias", 2),
Category: "unintended_bias",
Name: "Verzerrte Trainingsdaten",
Description: "Die Trainingsdaten sind nicht repraesentativ und enthalten systematische Verzerrungen, die zu unfairen oder fehlerhaften Modellergebnissen fuehren.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"ai_model"},
RegulationReferences: []string{"EU AI Act Art. 10", "EU AI Act Art. 71"},
SuggestedMitigations: mustMarshalJSON([]string{"Datensatz-Audit", "Ausgewogenes Sampling"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: update_failure (3 entries)
// ====================================================================
{
ID: hazardUUID("update_failure", 1),
Category: "update_failure",
Name: "Unvollstaendiges OTA-Update",
Description: "Ein Over-the-Air-Update wird nur teilweise uebertragen oder angewendet, wodurch das System in einem inkonsistenten Zustand verbleibt.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"firmware", "software"},
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Atomare Updates", "Integritaetspruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("update_failure", 2),
Category: "update_failure",
Name: "Versionskonflikt nach Update",
Description: "Nach einem Update sind Software- und Firmware-Versionen inkompatibel, was zu Fehlfunktionen oder Ausfaellen fuehrt.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Kompatibilitaetsmatrix", "Staging-Tests"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("update_failure", 3),
Category: "update_failure",
Name: "Unkontrollierter Auto-Update",
Description: "Ein automatisches Update wird ohne Genehmigung oder ausserhalb eines Wartungsfensters eingespielt und stoert den laufenden Betrieb.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software"},
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Update-Genehmigung", "Wartungsfenster"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
}
// ====================================================================
// Neue Kategorien (extended library ~100 neue Eintraege)
// ====================================================================
extended := []HazardLibraryEntry{
// ====================================================================
// Category: software_fault (10 entries)
// ====================================================================
{
ID: hazardUUID("software_fault", 1),
Category: "software_fault",
Name: "Race Condition in Sicherheitsfunktion",
Description: "Zwei Tasks greifen ohne Synchronisation auf gemeinsame Ressourcen zu, was zu unvorhersehbarem Verhalten in sicherheitsrelevanten Funktionen fuehren kann.",
DefaultSeverity: 5,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"EU 2023/1230 Anhang I §1.2", "IEC 62304", "IEC 61508"},
SuggestedMitigations: mustMarshalJSON([]string{"Mutex/Semaphor", "RTOS-Task-Prioritaeten", "WCET-Analyse"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 2),
Category: "software_fault",
Name: "Stack Overflow in Echtzeit-Task",
Description: "Ein rekursiver Aufruf oder grosse lokale Variablen fuehren zum Stack-Ueberlauf, was Safety-Tasks zum Absturz bringt.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "IEC 61508"},
SuggestedMitigations: mustMarshalJSON([]string{"Stack-Groessen-Analyse", "Stack-Guard", "Statische Code-Analyse"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 3),
Category: "software_fault",
Name: "Integer Overflow in Sicherheitsberechnung",
Description: "Arithmetischer Ueberlauf bei der Berechnung sicherheitskritischer Grenzwerte fuehrt zu falschen Ergebnissen und unkontrolliertem Verhalten.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "MISRA-C", "IEC 61508"},
SuggestedMitigations: mustMarshalJSON([]string{"Datentyp-Pruefung", "Overflow-Detection", "MISRA-C-Analyse"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 4),
Category: "software_fault",
Name: "Deadlock zwischen Safety-Tasks",
Description: "Gegenseitige Sperrung von Tasks durch zyklische Ressourcenabhaengigkeiten verhindert die Ausfuehrung sicherheitsrelevanter Funktionen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "IEC 61508"},
SuggestedMitigations: mustMarshalJSON([]string{"Ressourcen-Hierarchie", "Watchdog", "Deadlock-Analyse"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 5),
Category: "software_fault",
Name: "Memory Leak im Langzeitbetrieb",
Description: "Nicht freigegebener Heap-Speicher akkumuliert sich ueber Zeit, bis das System abstuerzt und Sicherheitsfunktionen nicht mehr verfuegbar sind.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"software"},
RegulationReferences: []string{"IEC 62304", "IEC 61508"},
SuggestedMitigations: mustMarshalJSON([]string{"Memory-Profiling", "Valgrind", "Statisches Speichermanagement"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 6),
Category: "software_fault",
Name: "Null-Pointer-Dereferenz in Safety-Code",
Description: "Zugriff auf einen Null-Zeiger fuehrt zu einem undefinierten Systemzustand oder Absturz des sicherheitsrelevanten Software-Moduls.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "MISRA-C"},
SuggestedMitigations: mustMarshalJSON([]string{"Null-Check vor Zugriff", "Statische Analyse", "Defensiv-Programmierung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 7),
Category: "software_fault",
Name: "Unbehandelte Ausnahme in Safety-Code",
Description: "Eine nicht abgefangene Ausnahme bricht die Ausfuehrung des sicherheitsrelevanten Codes ab und hinterlaesst das System in einem undefinierten Zustand.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software"},
RegulationReferences: []string{"IEC 62304", "IEC 61508"},
SuggestedMitigations: mustMarshalJSON([]string{"Globaler Exception-Handler", "Exception-Safety-Analyse", "Fail-Safe-Rueckfall"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 8),
Category: "software_fault",
Name: "Korrupte Konfigurationsdaten",
Description: "Beschaedigte oder unvollstaendige Konfigurationsdaten werden ohne Validierung geladen und fuehren zu falschem Systemverhalten.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Konfig-Validierung", "CRC-Pruefung", "Fallback-Konfiguration"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 9),
Category: "software_fault",
Name: "Division durch Null in Regelkreis",
Description: "Ein Divisor im sicherheitsrelevanten Regelkreis erreicht den Wert Null, was zu einem Laufzeitfehler oder undefiniertem Ergebnis fuehrt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "IEC 61508", "MISRA-C"},
SuggestedMitigations: mustMarshalJSON([]string{"Vorbedingungspruefung", "Statische Analyse", "Defensiv-Programmierung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("software_fault", 10),
Category: "software_fault",
Name: "Falscher Safety-Parameter durch Software-Bug",
Description: "Ein Software-Fehler setzt einen sicherheitsrelevanten Parameter auf einen falschen Wert, ohne dass eine Plausibilitaetspruefung dies erkennt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "IEC 61508", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Parametervalidierung", "Redundante Speicherung", "Diversitaere Pruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: hmi_error (8 entries)
// ====================================================================
{
ID: hazardUUID("hmi_error", 1),
Category: "hmi_error",
Name: "Falsche Einheitendarstellung",
Description: "Das HMI zeigt Werte in einer falschen Masseinheit an (z.B. mm statt inch), was zu Fehlbedienung und Maschinenfehlern fuehren kann.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"hmi", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang III", "EN ISO 9241"},
SuggestedMitigations: mustMarshalJSON([]string{"Einheiten-Label im UI", "Lokalisierungstests", "Einheiten-Konvertierungspruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("hmi_error", 2),
Category: "hmi_error",
Name: "Fehlender oder stummer Sicherheitsalarm",
Description: "Ein kritisches Sicherheitsereignis wird dem Bediener nicht oder nicht rechtzeitig angezeigt, weil die Alarmfunktion deaktiviert oder fehlerhaft ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"hmi", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "EN ISO 9241"},
SuggestedMitigations: mustMarshalJSON([]string{"Alarmtest im Rahmen der Inbetriebnahme", "Akustischer Backup-Alarm", "Alarmverwaltungssystem"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("hmi_error", 3),
Category: "hmi_error",
Name: "Sprachfehler in Bedienoberflaeche",
Description: "Fehlerhafte oder mehrdeutige Bezeichnungen in der Benutzersprache fuehren zu Fehlbedienung sicherheitsrelevanter Funktionen.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang III"},
SuggestedMitigations: mustMarshalJSON([]string{"Usability-Test", "Lokalisierungs-Review", "Mehrsprachige Dokumentation"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("hmi_error", 4),
Category: "hmi_error",
Name: "Fehlende Eingabevalidierung im HMI",
Description: "Das HMI akzeptiert ausserhalb des gueltigen Bereichs liegende Eingaben ohne Warnung und leitet sie an die Steuerung weiter.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"hmi", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62304"},
SuggestedMitigations: mustMarshalJSON([]string{"Grenzwertpruefung", "Eingabemaske mit Bereichen", "Warnung bei Grenzwertnaehe"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("hmi_error", 5),
Category: "hmi_error",
Name: "Defekter Statusindikator",
Description: "Ein LED, Anzeigeelement oder Softwaresymbol zeigt einen falschen Systemstatus an und verleitet den Bediener zu falschen Annahmen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang III"},
SuggestedMitigations: mustMarshalJSON([]string{"Regelmaessige HMI-Tests", "Selbsttest beim Einschalten", "Redundante Statusanzeige"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("hmi_error", 6),
Category: "hmi_error",
Name: "Quittierung ohne Ursachenbehebung",
Description: "Der Bediener kann einen Sicherheitsalarm quittieren, ohne die zugrundeliegende Ursache behoben zu haben, was das Risiko wiederkehrender Ereignisse erhoet.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"hmi", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Ursachen-Checkliste vor Quittierung", "Pflicht-Ursachen-Eingabe", "Audit-Log der Quittierungen"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("hmi_error", 7),
Category: "hmi_error",
Name: "Veraltete Anzeige durch Caching-Fehler",
Description: "Die HMI-Anzeige wird nicht aktualisiert und zeigt veraltete Sensorwerte oder Zustaende an, was zu Fehlentscheidungen fuehrt.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"hmi", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang III"},
SuggestedMitigations: mustMarshalJSON([]string{"Timestamp-Anzeige", "Refresh-Watchdog", "Verbindungsstatus-Indikator"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("hmi_error", 8),
Category: "hmi_error",
Name: "Fehlende Betriebsart-Kennzeichnung",
Description: "Die aktive Betriebsart (Automatik, Einrichten, Wartung) ist im HMI nicht eindeutig sichtbar, was zu unerwarteten Maschinenbewegungen fuehren kann.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"hmi", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Dauerhafte Betriebsart-Anzeige", "Farbliche Kennzeichnung", "Bestaetigung bei Modewechsel"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: mechanical_hazard (6 entries)
// ====================================================================
{
ID: hazardUUID("mechanical_hazard", 1),
Category: "mechanical_hazard",
Name: "Unerwarteter Anlauf nach Spannungsausfall",
Description: "Nach Wiederkehr der Versorgungsspannung laeuft die Maschine unerwartet an, ohne dass eine Startfreigabe durch den Bediener erfolgt ist.",
DefaultSeverity: 5,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "firmware"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.2.6", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Anlaufschutz", "Anti-Restart-Funktion", "Sicherheitsrelais"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 2),
Category: "mechanical_hazard",
Name: "Restenergie nach Abschalten",
Description: "Gespeicherte kinetische oder potentielle Energie (z.B. Schwungmasse, abgesenktes Werkzeug) wird nach dem Abschalten nicht sicher abgebaut.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Energieabbau-Prozedur", "Mechanische Haltevorrichtung", "LOTO-Freischaltung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 3),
Category: "mechanical_hazard",
Name: "Unerwartete Maschinenbewegung",
Description: "Die Maschine fuehrt eine unkontrollierte Bewegung durch (z.B. Antrieb faehrt ohne Kommando los), was Personen im Gefahrenbereich verletzt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator", "controller", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Safe Torque Off (STO)", "Geschwindigkeitsueberwachung", "Schutzzaun-Sensorik"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 4),
Category: "mechanical_hazard",
Name: "Teileauswurf durch Fehlfunktion",
Description: "Werkzeuge, Werkstuecke oder Maschinenteile werden bei einer Fehlfunktion unkontrolliert aus der Maschine geschleudert.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.2"},
SuggestedMitigations: mustMarshalJSON([]string{"Trennende Schutzeinrichtung", "Sicherheitsglas", "Spannkraft-Ueberwachung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 5),
Category: "mechanical_hazard",
Name: "Quetschstelle durch fehlende Schutzeinrichtung",
Description: "Zwischen beweglichen und festen Maschinenteilen entstehen Quetschstellen, die bei fehlendem Schutz zu schweren Verletzungen fuehren koennen.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.7", "ISO 13857"},
SuggestedMitigations: mustMarshalJSON([]string{"Schutzverkleidung", "Sicherheitsabstaende nach ISO 13857", "Lichtvorhang"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 6),
Category: "mechanical_hazard",
Name: "Instabile Struktur unter Last",
Description: "Die Maschinenstruktur oder ein Anbauteil versagt unter statischer oder dynamischer Belastung und gefaehrdet Personen in der Naehe.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"other"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.1"},
SuggestedMitigations: mustMarshalJSON([]string{"Festigkeitsberechnung", "Ueberlastsicherung", "Regelmaessige Inspektion"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: electrical_hazard (6 entries)
// ====================================================================
{
ID: hazardUUID("electrical_hazard", 1),
Category: "electrical_hazard",
Name: "Elektrischer Schlag an Bedienpanel",
Description: "Bediener kommen mit spannungsfuehrenden Teilen in Beruehrung, z.B. durch defekte Gehaeuseerdung oder fehlerhafte Isolierung.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"hmi", "controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Schutzkleinspannung (SELV)", "Schutzerdung", "Isolationsmonitoring"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 2),
Category: "electrical_hazard",
Name: "Lichtbogen durch Schaltfehler",
Description: "Ein Schaltfehler erzeugt einen Lichtbogen, der Bediener verletzen, Geraete beschaedigen oder einen Brand ausloesen kann.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Lichtbogenschutz-Schalter", "Kurzschlussschutz", "Geeignete Schaltgeraete"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 3),
Category: "electrical_hazard",
Name: "Kurzschluss durch Isolationsfehler",
Description: "Beschaedigte Kabelisolierungen fuehren zu einem Kurzschluss, der Feuer ausloesen oder Sicherheitsfunktionen ausser Betrieb setzen kann.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"network", "controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Isolationsueberwachung", "Kabelschutz", "Regelmaessige Sichtpruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 4),
Category: "electrical_hazard",
Name: "Erdschluss in Steuerkreis",
Description: "Ein Erdschluss im Steuerkreis kann unbeabsichtigte Schaltzustaende ausloesen und Sicherheitsfunktionen beeinflussen.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "network"},
RegulationReferences: []string{"IEC 60204-1", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Erdschluss-Monitoring", "IT-Netz fuer Steuerkreise", "Regelmaessige Pruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 5),
Category: "electrical_hazard",
Name: "Gespeicherte Energie in Kondensatoren",
Description: "Nach dem Abschalten verbleiben hohe Spannungen in Kondensatoren (z.B. Frequenzumrichter, USV), was bei Wartungsarbeiten gefaehrlich ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Entladewartezeit", "Automatische Entladeschaltung", "Warnhinweise am Geraet"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 6),
Category: "electrical_hazard",
Name: "Elektromagnetische Kopplung auf Safety-Leitung",
Description: "Hochfrequente Stoerfelder koppeln auf ungeschirmte Safety-Leitungen und erzeugen Falschsignale, die Sicherheitsfunktionen fehl ausloesen.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"network", "sensor"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Geschirmte Kabel", "Raeumliche Trennung", "EMV-Pruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: thermal_hazard (4 entries)
// ====================================================================
{
ID: hazardUUID("thermal_hazard", 1),
Category: "thermal_hazard",
Name: "Ueberhitzung der Steuereinheit",
Description: "Die Steuereinheit ueberschreitet die zulaessige Betriebstemperatur durch Lueftungsausfall oder hohe Umgebungstemperatur, was zu Fehlfunktionen fuehrt.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "firmware"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068"},
SuggestedMitigations: mustMarshalJSON([]string{"Temperaturueberwachung", "Redundante Lueftung", "Thermisches Abschalten"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("thermal_hazard", 2),
Category: "thermal_hazard",
Name: "Brandgefahr durch Leistungselektronik",
Description: "Defekte Leistungshalbleiter oder Kondensatoren in der Leistungselektronik erwaermen sich unkontrolliert und koennen einen Brand ausloesen.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Thermosicherungen", "Temperatursensoren", "Brandschutzmassnahmen"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("thermal_hazard", 3),
Category: "thermal_hazard",
Name: "Einfrieren bei Tieftemperatur",
Description: "Sehr tiefe Umgebungstemperaturen fuehren zum Einfrieren von Hydraulikleitungen oder Elektronik und damit zum Ausfall von Sicherheitsfunktionen.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "actuator"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068"},
SuggestedMitigations: mustMarshalJSON([]string{"Heizung", "Mindestbetriebstemperatur definieren", "Temperatursensor"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("thermal_hazard", 4),
Category: "thermal_hazard",
Name: "Waermestress an Kabelisolierung",
Description: "Langfristige Einwirkung hoher Temperaturen auf Kabelisolierungen fuehrt zu Alterung und Isolationsversagen mit Kurzschlussrisiko.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"network", "controller"},
RegulationReferences: []string{"IEC 60204-1", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Hitzebestaendige Kabel (z.B. PTFE)", "Kabelverlegung mit Abstand zur Waermequelle", "Regelmaessige Inspektion"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: emc_hazard (5 entries)
// ====================================================================
{
ID: hazardUUID("emc_hazard", 1),
Category: "emc_hazard",
Name: "EMV-Stoerabstrahlung auf Safety-Bus",
Description: "Hohe elektromagnetische Stoerabstrahlung aus benachbarten Geraeten stoert den industriellen Safety-Bus (z.B. PROFIsafe) und erzeugt Kommunikationsfehler.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"network", "controller"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 62061", "IEC 61784-3"},
SuggestedMitigations: mustMarshalJSON([]string{"EMV-gerechte Verkabelung", "Schirmung", "EMC-Pruefung nach EN 55011"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("emc_hazard", 2),
Category: "emc_hazard",
Name: "Unbeabsichtigte elektromagnetische Abstrahlung",
Description: "Die Maschine selbst strahlt starke EM-Felder ab, die andere sicherheitsrelevante Einrichtungen in der Naehe stoeren.",
DefaultSeverity: 2,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "actuator"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU"},
SuggestedMitigations: mustMarshalJSON([]string{"EMV-Filter", "Gehaeuseabschirmung", "CE-Zulassung Frequenzumrichter"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("emc_hazard", 3),
Category: "emc_hazard",
Name: "Frequenzumrichter-Stoerung auf Steuerleitung",
Description: "Der Frequenzumrichter erzeugt hochfrequente Stoerungen, die auf benachbarte Steuerleitungen koppeln und falsche Signale erzeugen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"actuator", "network"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Motorfilter", "Kabeltrennabstand", "Separate Kabelkanaele"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("emc_hazard", 4),
Category: "emc_hazard",
Name: "ESD-Schaden an Elektronik",
Description: "Elektrostatische Entladung bei Wartung oder Austausch beschaedigt empfindliche Elektronikbauteile, was zu latenten Fehlfunktionen fuehrt.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "firmware"},
RegulationReferences: []string{"IEC 61000-4-2", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"ESD-Schulung", "ESD-Schutzausruestung", "ESD-gerechte Verpackung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("emc_hazard", 5),
Category: "emc_hazard",
Name: "HF-Stoerung des Sicherheitssensors",
Description: "Hochfrequenz-Stoerquellen (z.B. Schweissgeraete, Mobiltelefone) beeinflussen die Funktion von Sicherheitssensoren (Lichtvorhang, Scanner).",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"sensor"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 61496"},
SuggestedMitigations: mustMarshalJSON([]string{"EMV-zertifizierte Sicherheitssensoren", "HF-Quellen trennen", "Gegensprechanlagenverbot in Gefahrenzone"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: configuration_error (8 entries)
// ====================================================================
{
ID: hazardUUID("configuration_error", 1),
Category: "configuration_error",
Name: "Falscher Safety-Parameter bei Inbetriebnahme",
Description: "Beim Einrichten werden sicherheitsrelevante Parameter (z.B. Maximalgeschwindigkeit, Abschaltgrenzen) falsch konfiguriert und nicht verifiziert.",
DefaultSeverity: 5,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Parameterpruefung nach Inbetriebnahme", "4-Augen-Prinzip", "Parameterprotokoll in technischer Akte"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("configuration_error", 2),
Category: "configuration_error",
Name: "Factory Reset loescht Sicherheitskonfiguration",
Description: "Ein Factory Reset setzt alle Parameter auf Werkseinstellungen zurueck, einschliesslich sicherheitsrelevanter Konfigurationen, ohne Warnung.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"firmware", "software"},
RegulationReferences: []string{"IEC 62304", "CRA", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Separate Safety-Partition", "Bestaetigung vor Reset", "Safety-Config vor Reset sichern"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("configuration_error", 3),
Category: "configuration_error",
Name: "Fehlerhafte Parameter-Migration bei Update",
Description: "Beim Software-Update werden vorhandene Konfigurationsparameter nicht korrekt in das neue Format migriert, was zu falschen Systemeinstellungen fuehrt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"Migrations-Skript-Tests", "Konfig-Backup vor Update", "Post-Update-Verifikation"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("configuration_error", 4),
Category: "configuration_error",
Name: "Konflikthafte redundante Einstellungen",
Description: "Widersprüchliche Parameter in verschiedenen Konfigurationsdateien oder -ebenen fuehren zu unvorhersehbarem Systemverhalten.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62304", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Konfig-Validierung beim Start", "Einzelne Quelle fuer Safety-Params", "Konsistenzpruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("configuration_error", 5),
Category: "configuration_error",
Name: "Hard-coded Credentials in Konfiguration",
Description: "Passwörter oder Schluessel sind fest im Code oder in Konfigurationsdateien hinterlegt und koennen nicht geaendert werden.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"CRA", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Secrets-Management", "Kein Hard-Coding", "Credential-Scan im CI"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("configuration_error", 6),
Category: "configuration_error",
Name: "Debug-Modus in Produktionsumgebung aktiv",
Description: "Debug-Schnittstellen oder erhoehte Logging-Level sind in der Produktionsumgebung aktiv und ermoeglichen Angreifern Zugang zu sensiblen Systeminfos.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"CRA", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Build-Konfiguration pruefe Debug-Flag", "Produktions-Checkliste", "Debug-Port-Deaktivierung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("configuration_error", 7),
Category: "configuration_error",
Name: "Out-of-Bounds-Eingabe ohne Validierung",
Description: "Nutzereingaben oder Schnittstellendaten werden ohne Bereichspruefung in sicherheitsrelevante Parameter uebernommen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "hmi"},
RegulationReferences: []string{"IEC 62304", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Eingabevalidierung", "Bereichsgrenzen definieren", "Sanity-Check"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("configuration_error", 8),
Category: "configuration_error",
Name: "Konfigurationsdatei nicht schreibgeschuetzt",
Description: "Sicherheitsrelevante Konfigurationsdateien koennen von unautorisierten Nutzern oder Prozessen veraendert werden.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "firmware"},
RegulationReferences: []string{"IEC 62443", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"Dateisystem-Berechtigungen", "Code-Signing fuer Konfig", "Integritaetspruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: safety_function_failure (8 entries)
// ====================================================================
{
ID: hazardUUID("safety_function_failure", 1),
Category: "safety_function_failure",
Name: "Not-Halt trennt Energieversorgung nicht",
Description: "Der Not-Halt-Taster betaetigt die Sicherheitsschalter, die Energiezufuhr wird jedoch nicht vollstaendig unterbrochen, weil das Sicherheitsrelais versagt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "actuator"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.2.4", "IEC 60947-5-5", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Regelmaessiger Not-Halt-Test", "Redundantes Sicherheitsrelais", "Selbstueberwachender Sicherheitskreis"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 2),
Category: "safety_function_failure",
Name: "Schutztuer-Monitoring umgangen",
Description: "Das Schutztuer-Positionssignal wird durch einen Fehler oder Manipulation als 'geschlossen' gemeldet, obwohl die Tuer offen ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"sensor", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 14119", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Zwangsöffnender Positionsschalter", "Codierter Sicherheitssensor", "Anti-Tamper-Masssnahmen"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 3),
Category: "safety_function_failure",
Name: "Safe Speed Monitoring fehlt",
Description: "Beim Einrichten im reduzierten Betrieb fehlt eine unabhaengige Geschwindigkeitsueberwachung, so dass der Bediener nicht ausreichend geschuetzt ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62061", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Sicherheitsumrichter mit SLS", "Unabhaengige Drehzahlmessung", "SIL-2-Geschwindigkeitsueberwachung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 4),
Category: "safety_function_failure",
Name: "STO-Funktion (Safe Torque Off) Fehler",
Description: "Die STO-Sicherheitsfunktion schaltet den Antriebsmoment nicht ab, obwohl die Funktion aktiviert wurde, z.B. durch Fehler im Sicherheits-SPS-Ausgang.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator", "controller"},
RegulationReferences: []string{"IEC 61800-5-2", "Maschinenverordnung 2023/1230", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"STO-Pruefung bei Inbetriebnahme", "Pruefzyklus im Betrieb", "Zertifizierter Sicherheitsumrichter"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 5),
Category: "safety_function_failure",
Name: "Muting-Missbrauch bei Lichtvorhang",
Description: "Die Muting-Funktion des Lichtvorhangs wird durch Fehler oder Manipulation zu lange oder unkontrolliert aktiviert, was den Schutz aufhebt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"sensor", "controller"},
RegulationReferences: []string{"IEC 61496-3", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Zeitbegrenztes Muting", "Muting-Lampe und Alarm", "Protokollierung der Muting-Ereignisse"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 6),
Category: "safety_function_failure",
Name: "Zweihand-Taster durch Gegenstand ueberbrueckt",
Description: "Die Zweihand-Betaetigungseinrichtung wird durch ein eingeklemmtes Objekt permanent aktiviert, was den Bediener aus dem Schutzkonzept loest.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"hmi", "controller"},
RegulationReferences: []string{"ISO 13851", "Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Anti-Tie-Down-Pruefung", "Typ-III-Zweihand-Taster", "Regelmaessige Funktionskontrolle"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 7),
Category: "safety_function_failure",
Name: "Sicherheitsrelais-Ausfall ohne Erkennung",
Description: "Ein Sicherheitsrelais versagt unentdeckt (z.B. verklebte Kontakte), sodass der Sicherheitskreis nicht mehr auftrennt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller"},
RegulationReferences: []string{"ISO 13849", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Selbstueberwachung (zwangsgefuehrt)", "Regelmaessiger Testlauf", "Redundantes Relais"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 8),
Category: "safety_function_failure",
Name: "Logic-Solver-Fehler in Sicherheits-SPS",
Description: "Die Sicherheitssteuerung (Safety-SPS) fuehrt sicherheitsrelevante Logik fehlerhaft aus, z.B. durch Speicherfehler oder Prozessorfehler.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"controller", "software"},
RegulationReferences: []string{"IEC 61511", "IEC 61508", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"SIL-zertifizierte SPS", "Watchdog", "Selbsttest-Routinen (BIST)"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: logging_audit_failure (5 entries)
// ====================================================================
{
ID: hazardUUID("logging_audit_failure", 1),
Category: "logging_audit_failure",
Name: "Safety-Events nicht protokolliert",
Description: "Sicherheitsrelevante Ereignisse (Alarme, Not-Halt-Betaetigungen, Fehlerzustaende) werden nicht in ein Protokoll geschrieben.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62443", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"Pflicht-Logging Safety-Events", "Unveraenderliches Audit-Log", "Log-Integritaetspruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("logging_audit_failure", 2),
Category: "logging_audit_failure",
Name: "Log-Manipulation moeglich",
Description: "Authentifizierte Benutzer oder Angreifer koennen Protokolleintraege aendern oder loeschen und so Beweise fuer Sicherheitsvorfaelle vernichten.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software"},
RegulationReferences: []string{"CRA", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Write-Once-Speicher", "Kryptografische Signaturen", "Externes Log-Management"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("logging_audit_failure", 3),
Category: "logging_audit_failure",
Name: "Log-Overflow ueberschreibt alte Eintraege",
Description: "Wenn der Log-Speicher voll ist, werden aeltere Eintraege ohne Warnung ueberschrieben, was eine lueckenlose Rueckverfolgung verhindert.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"software", "controller"},
RegulationReferences: []string{"CRA", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Log-Kapazitaetsalarm", "Externes Log-System", "Zirkulaerpuffer mit Warnschwelle"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("logging_audit_failure", 4),
Category: "logging_audit_failure",
Name: "Fehlende Zeitstempel in Protokolleintraegen",
Description: "Log-Eintraege enthalten keine oder ungenaue Zeitstempel, was die zeitliche Rekonstruktion von Ereignissen bei der Fehlersuche verhindert.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "controller"},
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"NTP-Synchronisation", "RTC im Geraet", "ISO-8601-Zeitstempel"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("logging_audit_failure", 5),
Category: "logging_audit_failure",
Name: "Audit-Trail loeschbar durch Bediener",
Description: "Der Audit-Trail kann von einem normalen Bediener geloescht werden, was die Nachvollziehbarkeit von Sicherheitsereignissen untergaebt.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software"},
RegulationReferences: []string{"CRA", "IEC 62443", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"RBAC: Nur Admin darf loeschen", "Log-Export vor Loeschung", "Unanderbare Log-Speicherung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: integration_error (8 entries)
// ====================================================================
{
ID: hazardUUID("integration_error", 1),
Category: "integration_error",
Name: "Datentyp-Mismatch an Schnittstelle",
Description: "Zwei Systeme tauschen Daten ueber eine Schnittstelle aus, die inkompatible Datentypen verwendet, was zu Interpretationsfehlern fuehrt.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "network"},
RegulationReferences: []string{"IEC 62304", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Schnittstellendefinition (IDL/Protobuf)", "Integrationstests", "Datentypvalidierung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("integration_error", 2),
Category: "integration_error",
Name: "Endianness-Fehler bei Datenuebertragung",
Description: "Big-Endian- und Little-Endian-Systeme kommunizieren ohne Byte-Order-Konvertierung, was zu falsch interpretierten numerischen Werten fuehrt.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "network"},
RegulationReferences: []string{"IEC 62304", "IEC 62443"},
SuggestedMitigations: mustMarshalJSON([]string{"Explizite Byte-Order-Definiton", "Integrationstests", "Schnittstellenspezifikation"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("integration_error", 3),
Category: "integration_error",
Name: "Protokoll-Versions-Konflikt",
Description: "Sender und Empfaenger verwenden unterschiedliche Protokollversionen, die nicht rueckwaertskompatibel sind, was zu Paketablehnung oder Fehlinterpretation fuehrt.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "network", "firmware"},
RegulationReferences: []string{"IEC 62443", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"Versions-Aushandlung beim Verbindungsaufbau", "Backward-Compatibilitaet", "Kompatibilitaets-Matrix"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("integration_error", 4),
Category: "integration_error",
Name: "Timeout nicht behandelt bei Kommunikation",
Description: "Eine Kommunikationsverbindung bricht ab oder antwortet nicht, der Sender erkennt dies nicht und wartet unendlich lang.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "network"},
RegulationReferences: []string{"IEC 62443", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Timeout-Konfiguration", "Watchdog-Timer", "Fail-Safe bei Verbindungsverlust"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("integration_error", 5),
Category: "integration_error",
Name: "Buffer Overflow an Schnittstelle",
Description: "Eine Schnittstelle akzeptiert Eingaben, die groesser als der zugewiesene Puffer sind, was zu Speicher-Ueberschreibung und Kontrollfluss-Manipulation fuehrt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "firmware", "network"},
RegulationReferences: []string{"CRA", "IEC 62443", "IEC 62304"},
SuggestedMitigations: mustMarshalJSON([]string{"Laengenvalidierung", "Sichere Puffer-Funktionen", "Statische Analyse (z.B. MISRA)"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("integration_error", 6),
Category: "integration_error",
Name: "Fehlender Heartbeat bei Safety-Verbindung",
Description: "Eine Safety-Kommunikationsverbindung sendet keinen periodischen Heartbeat, so dass ein stiller Ausfall (z.B. unterbrochenes Kabel) nicht erkannt wird.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"network", "software"},
RegulationReferences: []string{"IEC 61784-3", "ISO 13849", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Heartbeat-Protokoll", "Verbindungsueberwachung", "Safe-State bei Heartbeat-Ausfall"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("integration_error", 7),
Category: "integration_error",
Name: "Falscher Skalierungsfaktor bei Sensordaten",
Description: "Sensordaten werden mit einem falschen Faktor skaliert, was zu signifikant fehlerhaften Messwerten und moeglichen Fehlentscheidungen fuehrt.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"sensor", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62304"},
SuggestedMitigations: mustMarshalJSON([]string{"Kalibrierungspruefung", "Plausibilitaetstest", "Schnittstellendokumentation"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("integration_error", 8),
Category: "integration_error",
Name: "Einheitenfehler (mm vs. inch)",
Description: "Unterschiedliche Masseinheiten zwischen Systemen fuehren zu fehlerhaften Bewegungsbefehlen oder Werkzeugpositionierungen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"software", "hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62304"},
SuggestedMitigations: mustMarshalJSON([]string{"Explizite Einheitendefinition", "Einheitenkonvertierung in der Schnittstelle", "Integrationstests"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: environmental_hazard (5 entries)
// ====================================================================
{
ID: hazardUUID("environmental_hazard", 1),
Category: "environmental_hazard",
Name: "Ausfall durch hohe Umgebungstemperatur",
Description: "Hohe Umgebungstemperaturen ueberschreiten die spezifizierten Grenzwerte der Elektronik oder Aktorik und fuehren zu Fehlfunktionen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "sensor"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2"},
SuggestedMitigations: mustMarshalJSON([]string{"Betriebstemperatur-Spezifikation einhalten", "Klimaanlagensystem", "Temperatursensor + Abschaltung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("environmental_hazard", 2),
Category: "environmental_hazard",
Name: "Ausfall bei Tieftemperatur",
Description: "Sehr tiefe Temperaturen reduzieren die Viskositaet von Hydraulikfluessigkeiten, beeinflussen Elektronik und fuehren zu mechanischen Ausfaellen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"actuator", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2"},
SuggestedMitigations: mustMarshalJSON([]string{"Tieftemperatur-spezifizierte Komponenten", "Heizung im Schaltschrank", "Anlaeufroutine bei Kaeltestart"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("environmental_hazard", 3),
Category: "environmental_hazard",
Name: "Korrosion durch Feuchtigkeit",
Description: "Hohe Luftfeuchtigkeit oder Kondenswasser fuehrt zur Korrosion von Kontakten und Leiterbahnen, was zu Ausfaellen und Isolationsfehlern fuehrt.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"controller", "sensor"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60529"},
SuggestedMitigations: mustMarshalJSON([]string{"IP-Schutz entsprechend der Umgebung", "Belueftung mit Filter", "Regelmaessige Inspektion"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("environmental_hazard", 4),
Category: "environmental_hazard",
Name: "Fehlfunktion durch Vibrationen",
Description: "Mechanische Vibrationen lockern Verbindungen, schuetteln Kontakte auf oder beschaedigen Loetpunkte in Elektronikbaugruppen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "sensor"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2-6"},
SuggestedMitigations: mustMarshalJSON([]string{"Vibrationsdaempfung", "Vergossene Elektronik", "Regelmaessige Verbindungskontrolle"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("environmental_hazard", 5),
Category: "environmental_hazard",
Name: "Kontamination durch Staub oder Fluessigkeiten",
Description: "Staub, Metallspaeene oder Kuehlmittel gelangen in das Gehaeuseinnere und fuehren zu Kurzschluessen, Isolationsfehlern oder Kuehlproblemen.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"controller", "hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60529"},
SuggestedMitigations: mustMarshalJSON([]string{"Hohe IP-Schutzklasse", "Dichtungen regelmaessig pruefen", "Ueberdruck im Schaltschrank"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: maintenance_hazard (6 entries)
// ====================================================================
{
ID: hazardUUID("maintenance_hazard", 1),
Category: "maintenance_hazard",
Name: "Wartung ohne LOTO-Prozedur",
Description: "Wartungsarbeiten werden ohne korrekte Lockout/Tagout-Prozedur durchgefuehrt, sodass die Maschine waehrend der Arbeit anlaufen kann.",
DefaultSeverity: 5,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3"},
SuggestedMitigations: mustMarshalJSON([]string{"LOTO-Funktion in Software", "Schulung", "Prozedur im Betriebshandbuch"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 2),
Category: "maintenance_hazard",
Name: "Fehlende LOTO-Funktion in Software",
Description: "Die Steuerungssoftware bietet keine Moeglichkeit, die Maschine fuer Wartungsarbeiten sicher zu sperren und zu verriegeln.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3"},
SuggestedMitigations: mustMarshalJSON([]string{"Software-LOTO implementieren", "Wartungsmodus mit Schluessel", "Energiesperrfunktion"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 3),
Category: "maintenance_hazard",
Name: "Wartung bei laufender Maschine",
Description: "Wartungsarbeiten werden an betriebener Maschine durchgefuehrt, weil kein erzwungener Wartungsmodus vorhanden ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Erzwungenes Abschalten fuer Wartungsmodus", "Schluesselschalter", "Schutzmassnahmen im Wartungsmodus"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 4),
Category: "maintenance_hazard",
Name: "Wartungs-Tool ohne Zugangskontrolle",
Description: "Ein Diagnose- oder Wartungswerkzeug ist ohne Authentifizierung zugaenglich und ermoeglicht die unbeaufsichtigte Aenderung von Sicherheitsparametern.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "hmi"},
RegulationReferences: []string{"IEC 62443", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"Authentifizierung fuer Wartungs-Tools", "Rollenkonzept", "Audit-Log fuer Wartungszugriffe"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 5),
Category: "maintenance_hazard",
Name: "Unsichere Demontage gefaehrlicher Baugruppen",
Description: "Die Betriebsanleitung beschreibt nicht, wie gefaehrliche Baugruppen (z.B. Hochvolt, gespeicherte Energie) sicher demontiert werden.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"other"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.7.4"},
SuggestedMitigations: mustMarshalJSON([]string{"Detaillierte Demontageanleitung", "Warnhinweise an Geraet", "Schulung des Wartungspersonals"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 6),
Category: "maintenance_hazard",
Name: "Wiederanlauf nach Wartung ohne Freigabeprozedur",
Description: "Nach Wartungsarbeiten wird die Maschine ohne formelle Freigabeprozedur wieder in Betrieb genommen, was zu Verletzungen bei noch anwesendem Personal fuehren kann.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Software-Wiederanlauf-Freigabe", "Gefahrenbereich-Pruefung vor Anlauf", "Akustisches Warnsignal vor Anlauf"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
}
entries = append(entries, extended...)
return entries
}