Benjamin Admin e7f2f98da3 feat: IACE CE-Compliance Module — Normen, Risikobewertung, Production Lines
Major features:
- 215 norms library with section references + Beuth URLs (A/B1/B2/C norms)
- 173 hazard patterns with detail fields (scenario, trigger, harm, zone)
- Deterministic pattern matching: Component × Lifecycle × Pattern cross-product
- SIL/PL auto-calculation from S×E×P risk graph
- Risk assessment table with editable S/E/P dropdowns
- Production Line Dashboard with animated station flow (Running Dots)
- IACE process flow + norms coverage on start page
- Non-blocking cookie banner, ProcessFlow SSR fix
- 104 Playwright E2E tests passing

Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
2026-05-07 10:53:26 +02:00

99 lines
5.8 KiB
Go

package iace
// builtinSoftwarePatterns returns HP029-HP034: software and control system hazard patterns.
func builtinSoftwarePatterns() []HazardPattern {
return []HazardPattern{
{
ID: "HP029", NameDE: "Software-Fehler in Steuerung", NameEN: "Software fault in controller",
RequiredComponentTags: []string{"has_software", "programmable"},
RequiredEnergyTags: []string{},
ExcludedComponentTags: []string{"has_ai"},
GeneratedHazardCats: []string{"software_fault"},
SuggestedMeasureIDs: []string{"M101", "M102", "M103"},
SuggestedEvidenceIDs: []string{"E01", "E14"},
Priority: 85,
ScenarioDE: "Softwarefehler (Logikfehler, Race Condition, Ueberlauf) fuehrt zu unbeabsichtigter Maschinenbewegung.",
TriggerDE: "Nicht abgefangener Fehlerzustand, falsche Parametrierung oder Timing-Problem in der SPS/Steuerung.",
HarmDE: "Unerwartete Aktorbewegung, Versagen der Abschaltfunktion, unkontrollierter Dauerlauf.",
AffectedDE: "Bedienpersonal, Personen im Maschinenbereich",
ZoneDE: "Gesamte Maschine (Wirkbereich aller softwaregesteuerter Aktoren)",
DefaultSeverity: 4, DefaultExposure: 2,
},
{
ID: "HP030", NameDE: "Sicherheitsfunktionsversagen", NameEN: "Safety function failure",
RequiredComponentTags: []string{"safety_device"},
RequiredEnergyTags: []string{},
GeneratedHazardCats: []string{"safety_function_failure"},
SuggestedMeasureIDs: []string{"M104", "M105", "M051"},
SuggestedEvidenceIDs: []string{"E01", "E07", "E08", "E09"},
Priority: 95,
ScenarioDE: "Sicherheitsrelevante Funktion (Not-Halt, Schutztuer, Lichtvorhang) versagt im Anforderungsfall.",
TriggerDE: "Hardware-Defekt, systematischer Fehler oder unentdeckter gefaehrlicher Ausfall der Sicherheitskomponente.",
HarmDE: "Kein rechtzeitiger Maschinenstopp, Verletzung durch fehlende Schutzfunktion, schwere Folgen.",
AffectedDE: "Bedienpersonal, alle Personen im Gefahrenbereich",
ZoneDE: "Schutzbereich hinter Schutzzaun, Lichtvorhang-Ebene, Not-Halt-Wirkbereich",
DefaultSeverity: 5, DefaultExposure: 2,
},
{
ID: "HP031", NameDE: "Konfigurationsfehler", NameEN: "Configuration error",
RequiredComponentTags: []string{"programmable"},
RequiredEnergyTags: []string{},
GeneratedHazardCats: []string{"configuration_error"},
SuggestedMeasureIDs: []string{"M145", "M146", "M121"},
SuggestedEvidenceIDs: []string{"E01", "E14"},
Priority: 70,
ScenarioDE: "Falsche Parametrierung von Achsgrenzen, Geschwindigkeiten oder Sicherheitsgrenzen nach Umruestung.",
TriggerDE: "Bediener oder Einrichter aendert Parameter ohne Validierung oder nutzt falsches Rezept/Programm.",
HarmDE: "Ueberfahren mechanischer Anschlaege, zu hohe Kraefte/Geschwindigkeiten, Kollision.",
AffectedDE: "Bedienpersonal, Einrichter",
ZoneDE: "Gesamte Maschine (alle parametrierbaren Achsen und Funktionen)",
DefaultSeverity: 3, DefaultExposure: 2,
},
{
ID: "HP032", NameDE: "Fehlende Protokollierung / Audit", NameEN: "Missing logging / audit",
RequiredComponentTags: []string{"has_software"},
RequiredEnergyTags: []string{},
GeneratedHazardCats: []string{"logging_audit_failure"},
SuggestedMeasureIDs: []string{"M142", "M149"},
SuggestedEvidenceIDs: []string{"E01"},
Priority: 50,
ScenarioDE: "Sicherheitsrelevante Ereignisse werden nicht protokolliert; Ursachenanalyse nach Vorfall unmoeglich.",
TriggerDE: "Fehlende oder unvollstaendige Logging-Implementierung fuer sicherheitsrelevante Zustandswechsel.",
HarmDE: "Kein direkter Personenschaden, aber erschwerter Nachweis und verzoegerte Fehlerbeseitigung.",
AffectedDE: "Indirekt alle Bediener (Wiederholungsgefahr unerkannter Fehler)",
ZoneDE: "Steuerungssystem, Sicherheits-SPS, HMI-Audit-Trail",
DefaultSeverity: 2, DefaultExposure: 3,
},
{
ID: "HP033", NameDE: "Update-Fehler / Rollback-Problem", NameEN: "Update failure / rollback problem",
RequiredComponentTags: []string{"has_software", "programmable"},
RequiredEnergyTags: []string{},
GeneratedHazardCats: []string{"update_failure"},
SuggestedMeasureIDs: []string{"M138", "M141", "M146"},
SuggestedEvidenceIDs: []string{"E01", "E14"},
Priority: 65,
ScenarioDE: "Software-Update der Steuerung scheitert oder fuehrt zu inkompatiblem Zustand mit Sicherheitsfunktionen.",
TriggerDE: "Unterbrochenes Update, inkompatible Firmware-Version oder fehlender Rollback-Mechanismus.",
HarmDE: "Steuerungsausfall, Verlust der Sicherheitslogik, unkontrollierter Maschinenzustand.",
AffectedDE: "Bedienpersonal, Wartungspersonal",
ZoneDE: "Steuerungssystem, Sicherheits-SPS, Antriebsregler",
DefaultSeverity: 3, DefaultExposure: 1,
},
{
ID: "HP034", NameDE: "Verriegelungs-Umgehungsgefahr", NameEN: "Interlock bypass risk",
RequiredComponentTags: []string{"interlocked"},
RequiredEnergyTags: []string{},
GeneratedHazardCats: []string{"safety_function_failure"},
SuggestedMeasureIDs: []string{"M051", "M104", "M107"},
SuggestedEvidenceIDs: []string{"E01", "E08"},
Priority: 85,
ScenarioDE: "Sicherheitsverriegelung (Schutztuer, Zweihandsteuerung) wird vom Bediener umgangen oder manipuliert.",
TriggerDE: "Festklemmen des Tuerschalters, Ueberbruecken der Zweihandbedienung oder Dauerbetaetigung mit Kabelbinder.",
HarmDE: "Voller Zugang zum Gefahrenbereich bei laufender Maschine, schwere Quetsch-/Schnittverletzung.",
AffectedDE: "Bedienpersonal, Einrichter",
ZoneDE: "Schutztuerbereich, Zweihand-Bedienpult, Verriegelungsschalter",
DefaultSeverity: 5, DefaultExposure: 2,
},
}
}