336 neue Patterns (HP1000-HP1335): - Mechanisch detailliert (85): Quetschen, Scheren, Einziehen pro Koerperteil - Elektrisch/Thermisch/Chemisch (85): Verbrennung, Einatmen, Hautkontakt - Software/Organisation/Umgebung (85): SPS, Sensor, Aktor, HMI, Notfall - Lebenszyklus/Verkettung/Retrofit (81): Beschaffung, Manipulation, Dritte Gesamtstand: 1000 Patterns + 751 Normen + 200 Massnahmen Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
1039 lines
54 KiB
Go
1039 lines
54 KiB
Go
package iace
|
|
|
|
// GetFinalPatternsC returns 85 software, control, sensor, actuator,
|
|
// HMI, safety function, organizational, environmental, ergonomic,
|
|
// and fire/emergency hazard patterns (HP1170-HP1254).
|
|
func GetFinalPatternsC() []HazardPattern {
|
|
return []HazardPattern{
|
|
// === SPS-Fehler (10) ===
|
|
{
|
|
ID: "HP1170", NameDE: "SPS-Programmfehler fuehrt zu Fehlbewegung", NameEN: "PLC program error causes wrong movement",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"software_fault"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 80, ScenarioDE: "SPS-Programm steuert Achse in falsche Position",
|
|
TriggerDE: "Logikfehler im Anwenderprogramm", HarmDE: "Kollision, Quetschung",
|
|
AffectedDE: "Bedienpersonal, Einrichter", ZoneDE: "Maschinenarbeitsraum",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1171", NameDE: "SPS-Speicherfehler Datenverlust", NameEN: "PLC memory error data loss",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"software_fault", "safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 75, ScenarioDE: "Speicherfehler verfaelscht Sicherheitsparameter",
|
|
TriggerDE: "Bitfehler, Alterung, EMV-Einfluss", HarmDE: "Unerkannter Gefahrenzustand",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 4, DefaultExposure: 1,
|
|
},
|
|
{
|
|
ID: "HP1172", NameDE: "SPS-Watchdog-Timeout Ausfall", NameEN: "PLC watchdog timeout failure",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"software_fault", "safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 78, ScenarioDE: "SPS-Zyklus ueberschreitet Watchdog-Zeit",
|
|
TriggerDE: "Endlosschleife, Ueberlast, Kommunikationsfehler", HarmDE: "Unkontrollierter Maschinenstopp",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1173", NameDE: "SPS-Taktzeit-Ueberschreitung", NameEN: "PLC cycle time overrun",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"software_fault"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "SPS reagiert verzoegert auf Sicherheitssignal",
|
|
TriggerDE: "Programmkomplexitaet, Interrupt-Ueberlauf", HarmDE: "Verzoegerter Stopp, Nachlauf",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Sicherheitszone",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1174", NameDE: "SPS-IO-Fehler Signalverlust", NameEN: "PLC I/O error signal loss",
|
|
RequiredComponentTags: []string{"programmable", "sensor_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"sensor_fault", "software_fault"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 75, ScenarioDE: "IO-Modul verliert Verbindung zu Sensor/Aktor",
|
|
TriggerDE: "Kontaktfehler, Moduldefekt, EMV", HarmDE: "Fehlerhafte Maschinenreaktion",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1175", NameDE: "Feldbusfehler Kommunikationsausfall", NameEN: "Fieldbus error communication loss",
|
|
RequiredComponentTags: []string{"programmable", "networked"},
|
|
RequiredEnergyTags: []string{"cyber"},
|
|
GeneratedHazardCats: []string{"communication_failure", "software_fault"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 75, ScenarioDE: "Feldbus faellt aus, Teilnehmer nicht erreichbar",
|
|
TriggerDE: "Kabelbruch, EMV, Adresskonflikt", HarmDE: "Unkontrollierter Zustand",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Maschinenanlage",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1176", NameDE: "SPS-Parameterverlust nach Neustart", NameEN: "PLC parameter loss after reboot",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"configuration_error"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Maschine startet mit Werkseinstellungen statt Sicherheitsparam.",
|
|
TriggerDE: "Batterieausfall, Flash-Fehler, Reset", HarmDE: "Ungeschuetzte Bewegung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 4, DefaultExposure: 1,
|
|
},
|
|
{
|
|
ID: "HP1177", NameDE: "SPS-Versionskonflikt nach Update", NameEN: "PLC version conflict after update",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"software_fault", "configuration_error"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Firmware-Update macht Sicherheitsprogramm inkompatibel",
|
|
TriggerDE: "Runtime-Update ohne Programmvalidierung", HarmDE: "Sicherheitsfunktion unwirksam",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 4, DefaultExposure: 1,
|
|
},
|
|
{
|
|
ID: "HP1178", NameDE: "SPS-Lizenzablauf Funktionsverlust", NameEN: "PLC license expiry function loss",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"software_fault"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 55, ScenarioDE: "Lizenzablauf deaktiviert Sicherheitsoptionen",
|
|
TriggerDE: "Abgelaufene Runtime-Lizenz, Dongle fehlt", HarmDE: "Reduzierter Funktionsumfang",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 3, DefaultExposure: 1,
|
|
},
|
|
{
|
|
ID: "HP1179", NameDE: "SPS-Hardwaredefekt CPU-Modul", NameEN: "PLC hardware defect CPU module",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 78, ScenarioDE: "CPU-Modul faellt aus, kein Programmlauf mehr",
|
|
TriggerDE: "Alterung, Ueberhitzung, Kondensatordefekt", HarmDE: "Kompletter Steuerungsausfall",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 4, DefaultExposure: 1,
|
|
},
|
|
// === Sensorik (10) ===
|
|
{
|
|
ID: "HP1180", NameDE: "Sensor defekt liefert Falschwert", NameEN: "Sensor defect delivers wrong value",
|
|
RequiredComponentTags: []string{"sensor_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"sensor_fault"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 75, ScenarioDE: "Defekter Sensor meldet falschen Zustand",
|
|
TriggerDE: "Elektronikdefekt, Ueberspannung", HarmDE: "Falsche Maschinenreaktion",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Sensorbereich, Gesamtmaschine",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1181", NameDE: "Sensordrift verfaelscht Messwert", NameEN: "Sensor drift falsifies reading",
|
|
RequiredComponentTags: []string{"sensor_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"sensor_fault"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Schleichende Messwertabweichung unerkannt",
|
|
TriggerDE: "Alterung, Temperatureinfluss", HarmDE: "Grenzwert wird nicht erkannt",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Messstelle",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1182", NameDE: "Sensorverschmutzung blindes Signal", NameEN: "Sensor contamination blind signal",
|
|
RequiredComponentTags: []string{"sensor_part", "chemical_risk"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"sensor_fault"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Verschmutzter Sensor erkennt Objekt nicht",
|
|
TriggerDE: "Staub, Oel, Spaene auf Sensorflaeche", HarmDE: "Schutzeinrichtung unwirksam",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Sensorbereich",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1183", NameDE: "EMV-Stoerung verfaelscht Sensorsignal", NameEN: "EMI disturbs sensor signal",
|
|
RequiredComponentTags: []string{"sensor_part", "electrical_part"},
|
|
RequiredEnergyTags: []string{"electromagnetic"},
|
|
GeneratedHazardCats: []string{"emc_hazard", "sensor_fault"},
|
|
SuggestedMeasureIDs: []string{"M001", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 72, ScenarioDE: "Elektromagnetische Stoerung verfaelscht Messwert",
|
|
TriggerDE: "Frequenzumrichter, Schweissanlage, Funkgeraet", HarmDE: "Fehlinterpretation Maschinenzustand",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1184", NameDE: "Sensorkabelbruch Signalausfall", NameEN: "Sensor cable break signal loss",
|
|
RequiredComponentTags: []string{"sensor_part", "moving_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"sensor_fault"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 70, ScenarioDE: "Sensorkabel bricht durch Biegewechsel",
|
|
TriggerDE: "Kabel in Schleppkette, scharfe Kante", HarmDE: "Sensorausfall, Blindflug",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Kabelweg, Schleppkette",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1185", NameDE: "Sensor-Kurzschluss durch Feuchtigkeit", NameEN: "Sensor short by moisture",
|
|
RequiredComponentTags: []string{"sensor_part", "electrical_part"},
|
|
RequiredEnergyTags: []string{"electrical"},
|
|
GeneratedHazardCats: []string{"sensor_fault", "electrical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M003"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E06"},
|
|
Priority: 65, ScenarioDE: "Feuchtigkeit verursacht Kurzschluss am Sensor",
|
|
TriggerDE: "Reinigung mit Wasser, Kondensation", HarmDE: "Sensorausfall, Fehlsignal",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Sensoranschluss",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1186", NameDE: "Falsche Kalibrierung nach Sensortausch", NameEN: "Wrong calibration after sensor swap",
|
|
RequiredComponentTags: []string{"sensor_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"sensor_fault", "configuration_error"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Ersatzsensor wird ohne Kalibrierung eingebaut",
|
|
TriggerDE: "Fehlende Kalibriervorschrift, Zeitdruck", HarmDE: "Systematischer Messfehler",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Messstelle",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1187", NameDE: "Sensoralterung Empfindlichkeitsverlust", NameEN: "Sensor aging sensitivity loss",
|
|
RequiredComponentTags: []string{"sensor_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"sensor_fault"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 58, ScenarioDE: "Gealterter Sensor reagiert traege oder gar nicht",
|
|
TriggerDE: "Ueberschrittene Lebensdauer, keine Pruefung", HarmDE: "Schleichender Funktionsverlust",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Messstelle",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1188", NameDE: "Sensor-Frostschaden Ausfall", NameEN: "Sensor frost damage failure",
|
|
RequiredComponentTags: []string{"sensor_part", "structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"sensor_fault"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 55, ScenarioDE: "Sensor faellt durch Frost aus",
|
|
TriggerDE: "Kondenswasser gefriert, Gehaeuse bricht", HarmDE: "Sensorausfall bei Kaelte",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Aussensensor, unbeheizter Bereich",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1189", NameDE: "Vibration loest Sensor aus Halterung", NameEN: "Vibration dislodges sensor",
|
|
RequiredComponentTags: []string{"sensor_part", "vibration_source"},
|
|
RequiredEnergyTags: []string{"vibration"},
|
|
GeneratedHazardCats: []string{"sensor_fault"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 60, ScenarioDE: "Vibration verschiebt Sensor aus Sollposition",
|
|
TriggerDE: "Dauervibration, lockere Verschraubung", HarmDE: "Falsche Erfassung, Blindzone",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Sensorhalterung",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
// === Aktorik (10) ===
|
|
{
|
|
ID: "HP1190", NameDE: "Ventil klemmt in offener Stellung", NameEN: "Valve stuck in open position",
|
|
RequiredComponentTags: []string{"hydraulic_part", "moving_part"},
|
|
RequiredEnergyTags: []string{"hydraulic_pressure"},
|
|
GeneratedHazardCats: []string{"pneumatic_hydraulic", "mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 78, ScenarioDE: "Hydraulikventil klemmt und Bewegung stoppt nicht",
|
|
TriggerDE: "Verschmutzung, Korrosion, Federbruch", HarmDE: "Unkontrollierte Bewegung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Aktorbereich",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1191", NameDE: "Motor blockiert bei Ueberlast", NameEN: "Motor blocked at overload",
|
|
RequiredComponentTags: []string{"electrical_part", "moving_part"},
|
|
RequiredEnergyTags: []string{"electrical_energy"},
|
|
GeneratedHazardCats: []string{"electrical_hazard", "thermal_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M003"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E06"},
|
|
Priority: 72, ScenarioDE: "Blockierter Motor ueberhitzt und raucht",
|
|
TriggerDE: "Mechanische Blockade, fehlender Motorschutz", HarmDE: "Motorbrand, Rauchentwicklung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Motorbereich",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1192", NameDE: "Bremse versagt bei Absenkbewegung", NameEN: "Brake fails during lowering",
|
|
RequiredComponentTags: []string{"moving_part", "gravity_risk"},
|
|
RequiredEnergyTags: []string{"gravitational"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 85, ScenarioDE: "Bremse haelt Last nicht, unkontrolliertes Absenken",
|
|
TriggerDE: "Bremsbelag verschlissen, Oelkontamination", HarmDE: "Quetschung unter absinkender Last",
|
|
AffectedDE: "Wartungspersonal, Bediener", ZoneDE: "Unterhalb der Last",
|
|
DefaultSeverity: 5, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1193", NameDE: "Kupplung rutscht bei Drehmoment", NameEN: "Clutch slips at torque",
|
|
RequiredComponentTags: []string{"rotating_part", "moving_part"},
|
|
RequiredEnergyTags: []string{"rotational"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 62, ScenarioDE: "Kupplung rutscht und Drehmoment wird nicht uebertragen",
|
|
TriggerDE: "Verschleiss, Ueberlast, Verunreinigung", HarmDE: "Unerwarteter Stillstand, Rueckschlag",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Kupplungsbereich",
|
|
DefaultSeverity: 2, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1194", NameDE: "Hydraulikzylinder undicht Druckverlust", NameEN: "Hydraulic cylinder leak pressure loss",
|
|
RequiredComponentTags: []string{"hydraulic_part", "high_pressure"},
|
|
RequiredEnergyTags: []string{"hydraulic_pressure"},
|
|
GeneratedHazardCats: []string{"pneumatic_hydraulic", "mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 78, ScenarioDE: "Zylinder verliert Druck durch Dichtungsleck",
|
|
TriggerDE: "Dichtungsverschleiss, Kolbenstangenschaden", HarmDE: "Langsames Absinken der Last",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Zylinderbereich, darunter",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1195", NameDE: "Getriebe defekt Zahnbruch", NameEN: "Gearbox defect tooth fracture",
|
|
RequiredComponentTags: []string{"rotating_part", "high_force"},
|
|
RequiredEnergyTags: []string{"rotational"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Zahnrad bricht und Antrieb blockiert oder durchdreht",
|
|
TriggerDE: "Ermuedung, Ueberlast, Fremdkoerper", HarmDE: "Rueckschlag, Splitterflug",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Getriebegehaeuse",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1196", NameDE: "Riemen gerissen Antriebsausfall", NameEN: "Belt broken drive failure",
|
|
RequiredComponentTags: []string{"rotating_part", "moving_part"},
|
|
RequiredEnergyTags: []string{"rotational"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M054"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Riemen reisst und schlaegt zurueck",
|
|
TriggerDE: "Verschleiss, Ueberlast, falsche Spannung", HarmDE: "Peitscheneffekt, Quetschung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Riementrieb",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1197", NameDE: "Kette gerissen Last stuerzt", NameEN: "Chain broken load falls",
|
|
RequiredComponentTags: []string{"moving_part", "gravity_risk", "high_force"},
|
|
RequiredEnergyTags: []string{"gravitational"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 82, ScenarioDE: "Hebekette bricht und Last stuerzt ab",
|
|
TriggerDE: "Verschleiss, Korrosion, Ueberlast", HarmDE: "Toedlicher Aufprall",
|
|
AffectedDE: "Personen unter Last", ZoneDE: "Lastbereich",
|
|
DefaultSeverity: 5, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1198", NameDE: "Zahnrad gebrochen Blockade", NameEN: "Gear broken blockage",
|
|
RequiredComponentTags: []string{"rotating_part", "high_force"},
|
|
RequiredEnergyTags: []string{"rotational"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Gebrochener Zahn blockiert Getriebe schlagartig",
|
|
TriggerDE: "Materialermuedung, Schlagbelastung", HarmDE: "Ploetzlicher Stopp, Rueckschlag",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Antriebsstrang",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1199", NameDE: "Lagerschaden fuehrt zu Heisslaufer", NameEN: "Bearing damage causes hot runner",
|
|
RequiredComponentTags: []string{"rotating_part", "high_temperature"},
|
|
RequiredEnergyTags: []string{"rotational"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard", "thermal_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M054"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 72, ScenarioDE: "Lager laeuft heiss durch Schmiermangel/Verschleiss",
|
|
TriggerDE: "Fehlende Schmierung, Ueberlast, Verschmutzung", HarmDE: "Brand, Kontaktverbrennung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Lagerstelle",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
// === HMI (5) ===
|
|
{
|
|
ID: "HP1200", NameDE: "Display zeigt falschen Maschinenzustand", NameEN: "Display shows wrong machine state",
|
|
RequiredComponentTags: []string{"user_interface", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"hmi_error"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 72, ScenarioDE: "Anzeige suggeriert sicheren Zustand obwohl gefaehrlich",
|
|
TriggerDE: "Softwarefehler, verzoegerte Aktualisierung", HarmDE: "Fehleinschaetzung durch Bediener",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Bedienfeld",
|
|
DefaultSeverity: 4, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1201", NameDE: "Taste blockiert Dauersignal", NameEN: "Button stuck continuous signal",
|
|
RequiredComponentTags: []string{"user_interface"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"hmi_error", "safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 70, ScenarioDE: "Blockierte Taste sendet Dauersignal fuer Bewegung",
|
|
TriggerDE: "Verschmutzung, mechanischer Defekt", HarmDE: "Ungewollte Maschinenbewegung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Bedienfeld, Maschinbereich",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1202", NameDE: "Touchscreen defekt Fehlbedienung", NameEN: "Touchscreen defect misoperation",
|
|
RequiredComponentTags: []string{"user_interface", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"hmi_error"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 62, ScenarioDE: "Touchscreen registriert falsche Position",
|
|
TriggerDE: "Kalibrierungsfehler, Sprung im Display", HarmDE: "Falscher Befehl wird ausgeloest",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Bedienfeld",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1203", NameDE: "Anzeige unleserlich bei Sonnenlicht", NameEN: "Display unreadable in sunlight",
|
|
RequiredComponentTags: []string{"user_interface"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"hmi_error", "ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 52, ScenarioDE: "Display ist bei Gegenlicht nicht ablesbar",
|
|
TriggerDE: "Sonneneinstrahlung, reflexionsstarke Scheibe", HarmDE: "Fehlablesung, falsche Aktion",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Bedienfeld Ausseneinsatz",
|
|
DefaultSeverity: 2, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1204", NameDE: "Falsche Bediensprache Missverstaendnis", NameEN: "Wrong HMI language misunderstanding",
|
|
RequiredComponentTags: []string{"user_interface", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"hmi_error"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 55, ScenarioDE: "HMI-Sprache nicht verstaendlich fuer Bediener",
|
|
TriggerDE: "Fremdsprachiger Bediener, keine Uebersetzung", HarmDE: "Fehlbedienung durch Missverstaendnis",
|
|
AffectedDE: "Fremdsprachiges Personal", ZoneDE: "Bedienfeld",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
// === Sicherheitsfunktion (10) ===
|
|
{
|
|
ID: "HP1205", NameDE: "Not-Halt-Taster defekt", NameEN: "Emergency stop button defective",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 85, ScenarioDE: "Not-Halt-Taster loest bei Betaetigung nicht aus",
|
|
TriggerDE: "Kontaktfehler, Kabelbruch, mechanischer Defekt", HarmDE: "Maschine laeuft trotz Not-Halt",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 5, DefaultExposure: 1,
|
|
},
|
|
{
|
|
ID: "HP1206", NameDE: "Lichtvorhang geblendet/verschmutzt", NameEN: "Light curtain blinded/dirty",
|
|
RequiredComponentTags: []string{"sensor_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 82, ScenarioDE: "Lichtvorhang erkennt Eingriff nicht",
|
|
TriggerDE: "Verschmutzung, Fremdlicht, Dejustierung", HarmDE: "Ungeschuetzter Zugang zur Gefahrstelle",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gefahrstelle hinter Lichtvorhang",
|
|
DefaultSeverity: 5, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1207", NameDE: "Schutztuer-Verriegelung ueberbrueckt", NameEN: "Safety door interlock bypassed",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M005", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 85, ScenarioDE: "Schutztuerschalter wird absichtlich ueberbrueckt",
|
|
TriggerDE: "Manipulation mit Draht/Magnet, Produktionsdruck", HarmDE: "Zugang bei laufender Maschine",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamter Gefahrbereich",
|
|
DefaultSeverity: 5, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1208", NameDE: "Zweihandschaltung defekt", NameEN: "Two-hand control defective",
|
|
RequiredComponentTags: []string{"structural_part", "moving_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 80, ScenarioDE: "Zweihandschaltung loest auch mit einer Hand aus",
|
|
TriggerDE: "Kontakt klemmt, Zeitfenster zu gross", HarmDE: "Hand im Gefahrbereich bei Ausloesung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gefahrstelle",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1209", NameDE: "Schaltmatte erkennt Person nicht", NameEN: "Safety mat does not detect person",
|
|
RequiredComponentTags: []string{"sensor_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 78, ScenarioDE: "Schaltmatte reagiert nicht auf Personengewicht",
|
|
TriggerDE: "Defekte Zelle, zu leichte Person, Ueberbrueckung", HarmDE: "Maschine startet trotz Anwesenheit",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Mattenbereich vor Maschine",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1210", NameDE: "Sicherheits-SPS interner Fehler", NameEN: "Safety PLC internal error",
|
|
RequiredComponentTags: []string{"programmable", "has_software"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"safety_function_failure", "software_fault"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 82, ScenarioDE: "Sicherheits-SPS erkennt eigenen Fehler nicht",
|
|
TriggerDE: "Common-Cause-Fehler, Softwarebug", HarmDE: "Alle Sicherheitsfunktionen unwirksam",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 5, DefaultExposure: 1,
|
|
},
|
|
{
|
|
ID: "HP1211", NameDE: "Bremsversagen Servomotor", NameEN: "Servo motor brake failure",
|
|
RequiredComponentTags: []string{"moving_part", "gravity_risk"},
|
|
RequiredEnergyTags: []string{"gravitational"},
|
|
GeneratedHazardCats: []string{"safety_function_failure", "mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 82, ScenarioDE: "Haltebremse des Servomotors haelt Last nicht",
|
|
TriggerDE: "Verschleiss, Ueberhitzung, Oelkontamination", HarmDE: "Unkontrolliertes Absinken",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Vertikalachse, Hubbereich",
|
|
DefaultSeverity: 5, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1212", NameDE: "Drehzahlueberwachung defekt", NameEN: "Speed monitor defective",
|
|
RequiredComponentTags: []string{"sensor_part", "rotating_part"},
|
|
RequiredEnergyTags: []string{"rotational"},
|
|
GeneratedHazardCats: []string{"safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 75, ScenarioDE: "Drehzahlwaechter erkennt Ueberdrehzahl nicht",
|
|
TriggerDE: "Sensordefekt, falsche Parametrierung", HarmDE: "Bauteilversagen durch Ueberdrehzahl",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Drehende Bauteile",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1213", NameDE: "Positionsueberwachung Fehler", NameEN: "Position monitor error",
|
|
RequiredComponentTags: []string{"sensor_part", "moving_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 72, ScenarioDE: "Positionssensor meldet falschen Achsstandort",
|
|
TriggerDE: "Encoderdefekt, Signalverlust", HarmDE: "Kollision, Ueberfahren Endlage",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Verfahrbereich",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1214", NameDE: "Druckueberwachung defekt", NameEN: "Pressure monitor defective",
|
|
RequiredComponentTags: []string{"sensor_part", "high_pressure"},
|
|
RequiredEnergyTags: []string{"pneumatic_pressure"},
|
|
GeneratedHazardCats: []string{"safety_function_failure", "pneumatic_hydraulic"},
|
|
SuggestedMeasureIDs: []string{"M001", "M051"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 78, ScenarioDE: "Druckschalter erkennt Ueberdruck nicht",
|
|
TriggerDE: "Sensordefekt, Verstopfung Messleitung", HarmDE: "Bersten, Leitungsbruch",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Drucksystem",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
// === Organisatorisch (10) ===
|
|
{
|
|
ID: "HP1215", NameDE: "Fehlende Unterweisung Maschinennutzung", NameEN: "Missing training machine use",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 72, ScenarioDE: "Bediener nutzt Maschine ohne Einweisung",
|
|
TriggerDE: "Neue Mitarbeiter, fehlende Dokumentation", HarmDE: "Fehlbedienung, Unfall",
|
|
AffectedDE: "Neue Mitarbeiter", ZoneDE: "Gesamte Maschine",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1216", NameDE: "Sprachbarriere Sicherheitsanweisung", NameEN: "Language barrier safety instruction",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Sicherheitshinweise werden nicht verstanden",
|
|
TriggerDE: "Fremdsprachiges Personal, nur deutsche Schilder", HarmDE: "Nichtbeachtung Sicherheitsregeln",
|
|
AffectedDE: "Fremdsprachiges Personal", ZoneDE: "Gesamter Betrieb",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1217", NameDE: "Zeitdruck fuehrt zu Abkuerzungen", NameEN: "Time pressure leads to shortcuts",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 70, ScenarioDE: "Sicherheitsschritte werden aus Zeitdruck uebersprungen",
|
|
TriggerDE: "Hoher Produktionsdruck, Akkordarbeit", HarmDE: "Erhoehtes Unfallrisiko",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamter Arbeitsplatz",
|
|
DefaultSeverity: 3, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1218", NameDE: "Schichtuebergabe Informationsverlust", NameEN: "Shift handover information loss",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Kritische Information geht bei Schichtwechsel verloren",
|
|
TriggerDE: "Fehlende Uebergabeprotokolle, Zeitmangel", HarmDE: "Fortsetzen unsicherer Zustaende",
|
|
AffectedDE: "Nachfolge-Schichtpersonal", ZoneDE: "Gesamter Arbeitsplatz",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1219", NameDE: "Fehlende Gefaehrdungsbeurteilung", NameEN: "Missing risk assessment",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 78, ScenarioDE: "Taetigkeit ohne aktuelle Gefaehrdungsbeurteilung",
|
|
TriggerDE: "Neue Maschine, geaenderte Taetigkeit, kein Update", HarmDE: "Unerkannte Gefahren",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Betreffender Arbeitsplatz",
|
|
DefaultSeverity: 4, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1220", NameDE: "Mangelnde Aufsicht Alleinarbeit", NameEN: "Insufficient supervision lone work",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Person arbeitet allein ohne Ueberwachung",
|
|
TriggerDE: "Nachtschicht, abgelegener Arbeitsplatz", HarmDE: "Verzoegerte Rettung bei Unfall",
|
|
AffectedDE: "Alleinarbeitende", ZoneDE: "Abgelegener Arbeitsplatz",
|
|
DefaultSeverity: 4, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1221", NameDE: "Fehlende PSA-Bereitstellung", NameEN: "Missing PPE provision",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 72, ScenarioDE: "Benoetigte PSA ist nicht verfuegbar oder defekt",
|
|
TriggerDE: "Kein Nachkauf, falsche Groesse, Verschleiss", HarmDE: "Ungeschuetzte Exposition",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Gesamter Arbeitsplatz",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1222", NameDE: "Unklare Zustaendigkeit Abschaltung", NameEN: "Unclear responsibility for shutdown",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Niemand fuehlt sich fuer Maschinenabschaltung verantwortlich",
|
|
TriggerDE: "Fehlende Rollenzuweisung, Schichtwechsel", HarmDE: "Maschine laeuft unkontrolliert",
|
|
AffectedDE: "Alle Personen", ZoneDE: "Maschinenbereich",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1223", NameDE: "Fehlende Betriebsanweisung", NameEN: "Missing operating instruction",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 70, ScenarioDE: "Betriebsanweisung fehlt oder ist veraltet",
|
|
TriggerDE: "Neue Maschine, fehlende Aktualisierung", HarmDE: "Fehlbedienung, Unfall",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Betreffende Maschine",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1224", NameDE: "Mangelnde Erste-Hilfe-Versorgung", NameEN: "Insufficient first aid provision",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Erste-Hilfe-Material fehlt oder abgelaufen",
|
|
TriggerDE: "Keine Pruefung, Verbrauch nicht ersetzt", HarmDE: "Verschlimmerung von Verletzungen",
|
|
AffectedDE: "Verletzte Personen", ZoneDE: "Gesamter Betrieb",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
// === Umgebung (10) ===
|
|
{
|
|
ID: "HP1225", NameDE: "Ungenueg. Beleuchtung Arbeitsplatz", NameEN: "Insufficient workplace lighting",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 55, ScenarioDE: "Zu dunkler Arbeitsplatz fuehrt zu Fehlhandlung",
|
|
TriggerDE: "Defekte Lampen, Blendung, Schattenbereiche", HarmDE: "Fehlgriff, Stolpersturz",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Arbeitsplatz",
|
|
DefaultSeverity: 2, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1226", NameDE: "Extreme Hitze am Arbeitsplatz", NameEN: "Extreme heat at workplace",
|
|
RequiredComponentTags: []string{"structural_part", "high_temperature"},
|
|
RequiredEnergyTags: []string{"thermal"},
|
|
GeneratedHazardCats: []string{"thermal_hazard", "ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 60, ScenarioDE: "Hohe Umgebungstemperatur verursacht Hitzestress",
|
|
TriggerDE: "Fehlende Lueftung, Maschinenabwaerme, Sommer", HarmDE: "Hitzschlag, Konzentrationsverlust",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Halle, Ofennaehe",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1227", NameDE: "Laermbereich ohne Kennzeichnung", NameEN: "Noise area without marking",
|
|
RequiredComponentTags: []string{"noise_source"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 60, ScenarioDE: "Laermbereich nicht gekennzeichnet, kein Gehoerschutz",
|
|
TriggerDE: "Fehlende Beschilderung", HarmDE: "Unbemerkter Gehoerschaden",
|
|
AffectedDE: "Besucher, ungewarntes Personal", ZoneDE: "Laermbereich",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1228", NameDE: "Enge Platzverhältnisse Fluchtweg", NameEN: "Confined space escape route",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Enger Arbeitsplatz behindert Flucht bei Gefahr",
|
|
TriggerDE: "Verstellter Fluchtweg, enge Bauweise", HarmDE: "Verzoegerte Flucht, Einschluss",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Enger Arbeitsbereich",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1229", NameDE: "Absturzgefahr erhoehter Arbeitsplatz", NameEN: "Fall hazard elevated workplace",
|
|
RequiredComponentTags: []string{"gravity_risk", "structural_part"},
|
|
RequiredEnergyTags: []string{"gravitational"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M005", "M141"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 80, ScenarioDE: "Arbeitsplatz in Hoehe ohne Absturzsicherung",
|
|
TriggerDE: "Fehlende Gelaender, offene Bodenluken", HarmDE: "Absturz, schwere Verletzung",
|
|
AffectedDE: "Wartungspersonal", ZoneDE: "Buehne, Podest, Dach",
|
|
DefaultSeverity: 5, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1230", NameDE: "Alleinarbeit ohne Ueberwachung", NameEN: "Lone work without monitoring",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Person arbeitet allein an gefaehrlicher Maschine",
|
|
TriggerDE: "Spaetschicht, Wochenende, abgelegener Ort", HarmDE: "Keine Rettung bei Bewusstlosigkeit",
|
|
AffectedDE: "Alleinarbeitende", ZoneDE: "Abgelegener Arbeitsplatz",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1231", NameDE: "Staplerverkehr im Fussbereich", NameEN: "Forklift traffic in pedestrian area",
|
|
RequiredComponentTags: []string{"moving_part", "structural_part"},
|
|
RequiredEnergyTags: []string{"kinetic"},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M005"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 72, ScenarioDE: "Stapler kreuzt Fussgaengerbereich",
|
|
TriggerDE: "Fehlende Trennung, keine Markierung", HarmDE: "Anfahren, Ueberfahren",
|
|
AffectedDE: "Fussgaenger", ZoneDE: "Kreuzungsbereich Stapler/Fussgaenger",
|
|
DefaultSeverity: 4, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1232", NameDE: "Baustelle neben laufendem Betrieb", NameEN: "Construction next to running operation",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"mechanical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M001", "M005"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Bauarbeiten neben laufender Produktion",
|
|
TriggerDE: "Parallelbetrieb, fehlende Absperrung", HarmDE: "Herabfallende Teile, Staub",
|
|
AffectedDE: "Bauarbeiter, Produktionspersonal", ZoneDE: "Grenzbereich Baustelle/Produktion",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1233", NameDE: "Freiluft-Arbeitsplatz Witterung", NameEN: "Outdoor workplace weather exposure",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 55, ScenarioDE: "Witterung verschaerft Gefahren (Wind, Eis, Regen)",
|
|
TriggerDE: "Arbeit im Freien bei Extremwetter", HarmDE: "Rutschsturz, Unterkuehlung",
|
|
AffectedDE: "Aussenpersonal", ZoneDE: "Freigelände",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1234", NameDE: "Nachtarbeit Muedigkeit", NameEN: "Night work fatigue",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 58, ScenarioDE: "Muedigkeit bei Nachtschicht erhoht Unfallrisiko",
|
|
TriggerDE: "Biorhythmus-Tief, Dauernachtschicht", HarmDE: "Reaktionsverzoegerung, Fehlhandlung",
|
|
AffectedDE: "Nachtschichtpersonal", ZoneDE: "Gesamter Arbeitsplatz",
|
|
DefaultSeverity: 3, DefaultExposure: 4,
|
|
},
|
|
// === Ergonomie (10) ===
|
|
{
|
|
ID: "HP1235", NameDE: "Schweres Heben ueber 25 kg", NameEN: "Heavy lifting above 25 kg",
|
|
RequiredComponentTags: []string{"structural_part", "gravity_risk"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Regelmaessiges Heben schwerer Lasten",
|
|
TriggerDE: "Fehlende Hebehilfe, falsche Hebetechnik", HarmDE: "Bandscheibenvorfall, Rueckenschaden",
|
|
AffectedDE: "Bedienpersonal, Lagerpersonal", ZoneDE: "Arbeitsplatz, Lager",
|
|
DefaultSeverity: 3, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1236", NameDE: "Haeufiges Tragen schwerer Teile", NameEN: "Frequent carrying heavy parts",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 62, ScenarioDE: "Wiederholtes Tragen ueber laengere Strecken",
|
|
TriggerDE: "Keine Transportmittel, weite Wege", HarmDE: "Muskel-Skelett-Erkrankung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Transportweg",
|
|
DefaultSeverity: 3, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1237", NameDE: "Ziehen/Schieben schwerer Wagen", NameEN: "Pulling/pushing heavy carts",
|
|
RequiredComponentTags: []string{"moving_part", "structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 58, ScenarioDE: "Schwere Wagen auf unebenem Boden bewegen",
|
|
TriggerDE: "Schlechte Rollen, Steigungen, nasser Boden", HarmDE: "Schulter-/Rueckenschmerz",
|
|
AffectedDE: "Logistikpersonal", ZoneDE: "Transportweg, Rampe",
|
|
DefaultSeverity: 2, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1238", NameDE: "Zwangshaltung an Maschine", NameEN: "Forced posture at machine",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 60, ScenarioDE: "Unguenstige Koerperhaltung durch Maschinendesign",
|
|
TriggerDE: "Schlechte Zugaenglichkeit, niedrige Oeffnung", HarmDE: "Chronische Gelenkbeschwerden",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Bedien-/Wartungsbereich",
|
|
DefaultSeverity: 2, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1239", NameDE: "Ueberkopfarbeit Schulterbelastung", NameEN: "Overhead work shoulder strain",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 58, ScenarioDE: "Dauerhaftes Arbeiten ueber Kopf",
|
|
TriggerDE: "Montage an Decke, fehlende Hebebuehne", HarmDE: "Schulterimpingement, Sehnenschaden",
|
|
AffectedDE: "Wartungspersonal, Monteure", ZoneDE: "Ueberkopf-Arbeitsbereich",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1240", NameDE: "Kniearbeit auf hartem Boden", NameEN: "Kneeling on hard floor",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 52, ScenarioDE: "Haeufiges Knien bei Montage/Wartungsarbeiten",
|
|
TriggerDE: "Bodennahe Arbeiten, fehlende Knieschoner", HarmDE: "Meniskusschaden (BK 2112)",
|
|
AffectedDE: "Wartungspersonal", ZoneDE: "Bodenbereich",
|
|
DefaultSeverity: 2, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1241", NameDE: "Dauerstehenarbeit ohne Wechsel", NameEN: "Prolonged standing without change",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 50, ScenarioDE: "Ganztaegiges Stehen ohne Sitzmoeglichkeit",
|
|
TriggerDE: "Maschinendesign erzwingt Stehen, keine Stehhilfe", HarmDE: "Venenleiden, Fussschmerzen",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Bedienplatz",
|
|
DefaultSeverity: 2, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1242", NameDE: "Repetitive Handbewegung RSI", NameEN: "Repetitive hand movement RSI",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 58, ScenarioDE: "Wiederholte gleichfoermige Handbewegung",
|
|
TriggerDE: "Akkordarbeit, Montage, Sortieren", HarmDE: "Karpaltunnelsyndrom, Sehnenscheidenentzuendung",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Handarbeitsplatz",
|
|
DefaultSeverity: 3, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1243", NameDE: "Bildschirmarbeitsplatz Fehlhaltung", NameEN: "VDU workplace poor posture",
|
|
RequiredComponentTags: []string{"user_interface"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 50, ScenarioDE: "Schlechte Ergonomie am Steuerungsbildschirm",
|
|
TriggerDE: "Falsche Monitorhoehe, kein ergon. Stuhl", HarmDE: "Nacken-/Rueckenschmerzen, Augenbelastung",
|
|
AffectedDE: "Bedienpersonal (Leitstand)", ZoneDE: "Leitstand, HMI-Platz",
|
|
DefaultSeverity: 2, DefaultExposure: 4,
|
|
},
|
|
{
|
|
ID: "HP1244", NameDE: "Schieben gegen Koerperschwerpunkt", NameEN: "Pushing against body center",
|
|
RequiredComponentTags: []string{"structural_part", "moving_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic_hazard"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 52, ScenarioDE: "Schwerlast wird mit Koerpereinsatz geschoben",
|
|
TriggerDE: "Fehlender Antrieb, blockierte Rollen", HarmDE: "Lendenwirbelbelastung",
|
|
AffectedDE: "Logistikpersonal", ZoneDE: "Transportbereich",
|
|
DefaultSeverity: 2, DefaultExposure: 3,
|
|
},
|
|
// === Brand/Notfall (10) ===
|
|
{
|
|
ID: "HP1245", NameDE: "Fluchtweg blockiert durch Material", NameEN: "Escape route blocked by material",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"fire_explosion"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 78, ScenarioDE: "Fluchtweg durch Paletten oder Material verstellt",
|
|
TriggerDE: "Fehlende Ordnung, Platzmangel", HarmDE: "Einschluss bei Brand, Panik",
|
|
AffectedDE: "Alle Personen", ZoneDE: "Fluchtweg, Notausgang",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1246", NameDE: "Brandmeldeanlage defekt", NameEN: "Fire alarm system defective",
|
|
RequiredComponentTags: []string{"sensor_part", "structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"fire_explosion", "safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 80, ScenarioDE: "Brandmelder erkennt Rauch nicht rechtzeitig",
|
|
TriggerDE: "Defekter Melder, leere Batterie, Staub", HarmDE: "Verzoegerte Evakuierung",
|
|
AffectedDE: "Alle Personen im Gebaeude", ZoneDE: "Gesamtes Gebaeude",
|
|
DefaultSeverity: 5, DefaultExposure: 1,
|
|
},
|
|
{
|
|
ID: "HP1247", NameDE: "Feuerloescher fehlt oder leer", NameEN: "Fire extinguisher missing or empty",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"fire_explosion"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 72, ScenarioDE: "Kein funktionsfaehiger Loescher am Brandort",
|
|
TriggerDE: "Fehlende Pruefung, Entnahme nicht ersetzt", HarmDE: "Brand kann sich ausbreiten",
|
|
AffectedDE: "Alle Personen", ZoneDE: "Brandort",
|
|
DefaultSeverity: 4, DefaultExposure: 1,
|
|
},
|
|
{
|
|
ID: "HP1248", NameDE: "Evakuierungsplan unklar/veraltet", NameEN: "Evacuation plan unclear/outdated",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"fire_explosion"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 65, ScenarioDE: "Personal kennt Fluchtweg und Sammelplatz nicht",
|
|
TriggerDE: "Fehlende Uebung, veralteter Plan", HarmDE: "Chaotische Evakuierung",
|
|
AffectedDE: "Alle Personen", ZoneDE: "Gesamtes Gebaeude",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1249", NameDE: "Erste-Hilfe-Kasten leer/abgelaufen", NameEN: "First aid kit empty/expired",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M141"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 58, ScenarioDE: "Verbandmaterial fehlt oder ist abgelaufen",
|
|
TriggerDE: "Keine Bestandskontrolle", HarmDE: "Mangelnde Erstversorgung",
|
|
AffectedDE: "Verletzte Personen", ZoneDE: "Sanitaetsbereich",
|
|
DefaultSeverity: 2, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1250", NameDE: "Notruf nicht moeglich (kein Empfang)", NameEN: "Emergency call impossible (no signal)",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"ergonomic"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 72, ScenarioDE: "Kein Notruf moeglich mangels Telefon/Empfang",
|
|
TriggerDE: "Kein Mobilnetz, kein Festnetz, Keller", HarmDE: "Verzoegerte Rettung",
|
|
AffectedDE: "Verletzte Personen", ZoneDE: "Abgelegener/unterirdischer Bereich",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1251", NameDE: "Brandschutztuer blockiert offen", NameEN: "Fire door propped open",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"fire_explosion"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 72, ScenarioDE: "Brandschutztuer wird verkeilt und kann nicht schliessen",
|
|
TriggerDE: "Bequemlichkeit, Lueftung, Transport", HarmDE: "Brandausbreitung ueber Abschnitte",
|
|
AffectedDE: "Alle Personen im Gebaeude", ZoneDE: "Brandabschnitt",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1252", NameDE: "Explosionsschutzdokument fehlt", NameEN: "Explosion protection document missing",
|
|
RequiredComponentTags: []string{"chemical_risk", "structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"fire_explosion"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E20"},
|
|
Priority: 72, ScenarioDE: "ATEX-Zonen nicht dokumentiert oder veraltet",
|
|
TriggerDE: "Fehlende Zoneneinteilung, neue Stoffe", HarmDE: "Ungeeignete Betriebsmittel in Zone",
|
|
AffectedDE: "Bedienpersonal", ZoneDE: "Ex-gefaehrdeter Bereich",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP1253", NameDE: "Brandlast zu hoch im Bereich", NameEN: "Fire load too high in area",
|
|
RequiredComponentTags: []string{"chemical_risk", "structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"fire_explosion"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01"},
|
|
Priority: 68, ScenarioDE: "Zu viel brennbares Material gelagert",
|
|
TriggerDE: "Ueberfuelltes Lager, Kartons neben Maschine", HarmDE: "Schnelle Brandausbreitung",
|
|
AffectedDE: "Alle Personen", ZoneDE: "Lager, Produktionsbereich",
|
|
DefaultSeverity: 3, DefaultExposure: 3,
|
|
},
|
|
{
|
|
ID: "HP1254", NameDE: "Loeschanlage defekt/nicht gewartet", NameEN: "Suppression system defective",
|
|
RequiredComponentTags: []string{"structural_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"fire_explosion", "safety_function_failure"},
|
|
SuggestedMeasureIDs: []string{"M001"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E08"},
|
|
Priority: 78, ScenarioDE: "Sprinkler-/Loeschanlage funktioniert nicht bei Brand",
|
|
TriggerDE: "Ventil geschlossen, Pumpe defekt, keine Wartung", HarmDE: "Brand wird nicht eingedaemmt",
|
|
AffectedDE: "Alle Personen im Gebaeude", ZoneDE: "Gesamtes Gebaeude",
|
|
DefaultSeverity: 5, DefaultExposure: 1,
|
|
},
|
|
}
|
|
}
|