package iace
import "time"
// builtinHazardsMachineSafety returns hazard library entries covering
// mechanical, environmental and machine safety hazards.
func builtinHazardsMachineSafety() []HazardLibraryEntry {
now := time.Now()
return []HazardLibraryEntry{
// Category: mechanical_hazard (6 entries)
// ====================================================================
{
ID: hazardUUID("mechanical_hazard", 1),
Category: "mechanical_hazard",
Name: "Unerwarteter Anlauf nach Spannungsausfall",
Description: "Nach Wiederkehr der Versorgungsspannung laeuft die Maschine unerwartet an, ohne dass eine Startfreigabe durch den Bediener erfolgt ist.",
DefaultSeverity: 5,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "firmware"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.2.6", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Anlaufschutz", "Anti-Restart-Funktion", "Sicherheitsrelais"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 2),
Category: "mechanical_hazard",
Name: "Restenergie nach Abschalten",
Description: "Gespeicherte kinetische oder potentielle Energie (z.B. Schwungmasse, abgesenktes Werkzeug) wird nach dem Abschalten nicht sicher abgebaut.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Energieabbau-Prozedur", "Mechanische Haltevorrichtung", "LOTO-Freischaltung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 3),
Category: "mechanical_hazard",
Name: "Unerwartete Maschinenbewegung",
Description: "Die Maschine fuehrt eine unkontrollierte Bewegung durch (z.B. Antrieb faehrt ohne Kommando los), was Personen im Gefahrenbereich verletzt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator", "controller", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Safe Torque Off (STO)", "Geschwindigkeitsueberwachung", "Schutzzaun-Sensorik"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 4),
Category: "mechanical_hazard",
Name: "Teileauswurf durch Fehlfunktion",
Description: "Werkzeuge, Werkstuecke oder Maschinenteile werden bei einer Fehlfunktion unkontrolliert aus der Maschine geschleudert.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.2"},
SuggestedMitigations: mustMarshalJSON([]string{"Trennende Schutzeinrichtung", "Sicherheitsglas", "Spannkraft-Ueberwachung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 5),
Category: "mechanical_hazard",
Name: "Quetschstelle durch fehlende Schutzeinrichtung",
Description: "Zwischen beweglichen und festen Maschinenteilen entstehen Quetschstellen, die bei fehlendem Schutz zu schweren Verletzungen fuehren koennen.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.7", "ISO 13857"},
SuggestedMitigations: mustMarshalJSON([]string{"Schutzverkleidung", "Sicherheitsabstaende nach ISO 13857", "Lichtvorhang"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("mechanical_hazard", 6),
Category: "mechanical_hazard",
Name: "Instabile Struktur unter Last",
Description: "Die Maschinenstruktur oder ein Anbauteil versagt unter statischer oder dynamischer Belastung und gefaehrdet Personen in der Naehe.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"other"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.1"},
SuggestedMitigations: mustMarshalJSON([]string{"Festigkeitsberechnung", "Ueberlastsicherung", "Regelmaessige Inspektion"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: electrical_hazard (6 entries)
// ====================================================================
{
ID: hazardUUID("electrical_hazard", 1),
Category: "electrical_hazard",
Name: "Elektrischer Schlag an Bedienpanel",
Description: "Bediener kommen mit spannungsfuehrenden Teilen in Beruehrung, z.B. durch defekte Gehaeuseerdung oder fehlerhafte Isolierung.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"hmi", "controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Schutzkleinspannung (SELV)", "Schutzerdung", "Isolationsmonitoring"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 2),
Category: "electrical_hazard",
Name: "Lichtbogen durch Schaltfehler",
Description: "Ein Schaltfehler erzeugt einen Lichtbogen, der Bediener verletzen, Geraete beschaedigen oder einen Brand ausloesen kann.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Lichtbogenschutz-Schalter", "Kurzschlussschutz", "Geeignete Schaltgeraete"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 3),
Category: "electrical_hazard",
Name: "Kurzschluss durch Isolationsfehler",
Description: "Beschaedigte Kabelisolierungen fuehren zu einem Kurzschluss, der Feuer ausloesen oder Sicherheitsfunktionen ausser Betrieb setzen kann.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"network", "controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Isolationsueberwachung", "Kabelschutz", "Regelmaessige Sichtpruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 4),
Category: "electrical_hazard",
Name: "Erdschluss in Steuerkreis",
Description: "Ein Erdschluss im Steuerkreis kann unbeabsichtigte Schaltzustaende ausloesen und Sicherheitsfunktionen beeinflussen.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "network"},
RegulationReferences: []string{"IEC 60204-1", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Erdschluss-Monitoring", "IT-Netz fuer Steuerkreise", "Regelmaessige Pruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 5),
Category: "electrical_hazard",
Name: "Gespeicherte Energie in Kondensatoren",
Description: "Nach dem Abschalten verbleiben hohe Spannungen in Kondensatoren (z.B. Frequenzumrichter, USV), was bei Wartungsarbeiten gefaehrlich ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Entladewartezeit", "Automatische Entladeschaltung", "Warnhinweise am Geraet"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("electrical_hazard", 6),
Category: "electrical_hazard",
Name: "Elektromagnetische Kopplung auf Safety-Leitung",
Description: "Hochfrequente Stoerfelder koppeln auf ungeschirmte Safety-Leitungen und erzeugen Falschsignale, die Sicherheitsfunktionen fehl ausloesen.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"network", "sensor"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Geschirmte Kabel", "Raeumliche Trennung", "EMV-Pruefung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: thermal_hazard (4 entries)
// ====================================================================
{
ID: hazardUUID("thermal_hazard", 1),
Category: "thermal_hazard",
Name: "Ueberhitzung der Steuereinheit",
Description: "Die Steuereinheit ueberschreitet die zulaessige Betriebstemperatur durch Lueftungsausfall oder hohe Umgebungstemperatur, was zu Fehlfunktionen fuehrt.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "firmware"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068"},
SuggestedMitigations: mustMarshalJSON([]string{"Temperaturueberwachung", "Redundante Lueftung", "Thermisches Abschalten"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("thermal_hazard", 2),
Category: "thermal_hazard",
Name: "Brandgefahr durch Leistungselektronik",
Description: "Defekte Leistungshalbleiter oder Kondensatoren in der Leistungselektronik erwaermen sich unkontrolliert und koennen einen Brand ausloesen.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller"},
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Thermosicherungen", "Temperatursensoren", "Brandschutzmassnahmen"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("thermal_hazard", 3),
Category: "thermal_hazard",
Name: "Einfrieren bei Tieftemperatur",
Description: "Sehr tiefe Umgebungstemperaturen fuehren zum Einfrieren von Hydraulikleitungen oder Elektronik und damit zum Ausfall von Sicherheitsfunktionen.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "actuator"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068"},
SuggestedMitigations: mustMarshalJSON([]string{"Heizung", "Mindestbetriebstemperatur definieren", "Temperatursensor"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("thermal_hazard", 4),
Category: "thermal_hazard",
Name: "Waermestress an Kabelisolierung",
Description: "Langfristige Einwirkung hoher Temperaturen auf Kabelisolierungen fuehrt zu Alterung und Isolationsversagen mit Kurzschlussrisiko.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"network", "controller"},
RegulationReferences: []string{"IEC 60204-1", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Hitzebestaendige Kabel (z.B. PTFE)", "Kabelverlegung mit Abstand zur Waermequelle", "Regelmaessige Inspektion"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: emc_hazard (5 entries)
// ====================================================================
{
ID: hazardUUID("emc_hazard", 1),
Category: "emc_hazard",
Name: "EMV-Stoerabstrahlung auf Safety-Bus",
Description: "Hohe elektromagnetische Stoerabstrahlung aus benachbarten Geraeten stoert den industriellen Safety-Bus (z.B. PROFIsafe) und erzeugt Kommunikationsfehler.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"network", "controller"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 62061", "IEC 61784-3"},
SuggestedMitigations: mustMarshalJSON([]string{"EMV-gerechte Verkabelung", "Schirmung", "EMC-Pruefung nach EN 55011"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("emc_hazard", 2),
Category: "emc_hazard",
Name: "Unbeabsichtigte elektromagnetische Abstrahlung",
Description: "Die Maschine selbst strahlt starke EM-Felder ab, die andere sicherheitsrelevante Einrichtungen in der Naehe stoeren.",
DefaultSeverity: 2,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "actuator"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU"},
SuggestedMitigations: mustMarshalJSON([]string{"EMV-Filter", "Gehaeuseabschirmung", "CE-Zulassung Frequenzumrichter"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("emc_hazard", 3),
Category: "emc_hazard",
Name: "Frequenzumrichter-Stoerung auf Steuerleitung",
Description: "Der Frequenzumrichter erzeugt hochfrequente Stoerungen, die auf benachbarte Steuerleitungen koppeln und falsche Signale erzeugen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"actuator", "network"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 60204-1"},
SuggestedMitigations: mustMarshalJSON([]string{"Motorfilter", "Kabeltrennabstand", "Separate Kabelkanaele"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("emc_hazard", 4),
Category: "emc_hazard",
Name: "ESD-Schaden an Elektronik",
Description: "Elektrostatische Entladung bei Wartung oder Austausch beschaedigt empfindliche Elektronikbauteile, was zu latenten Fehlfunktionen fuehrt.",
DefaultSeverity: 3,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "firmware"},
RegulationReferences: []string{"IEC 61000-4-2", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"ESD-Schulung", "ESD-Schutzausruestung", "ESD-gerechte Verpackung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("emc_hazard", 5),
Category: "emc_hazard",
Name: "HF-Stoerung des Sicherheitssensors",
Description: "Hochfrequenz-Stoerquellen (z.B. Schweissgeraete, Mobiltelefone) beeinflussen die Funktion von Sicherheitssensoren (Lichtvorhang, Scanner).",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"sensor"},
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 61496"},
SuggestedMitigations: mustMarshalJSON([]string{"EMV-zertifizierte Sicherheitssensoren", "HF-Quellen trennen", "Gegensprechanlagenverbot in Gefahrenzone"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: safety_function_failure (8 entries)
// ====================================================================
{
ID: hazardUUID("safety_function_failure", 1),
Category: "safety_function_failure",
Name: "Not-Halt trennt Energieversorgung nicht",
Description: "Der Not-Halt-Taster betaetigt die Sicherheitsschalter, die Energiezufuhr wird jedoch nicht vollstaendig unterbrochen, weil das Sicherheitsrelais versagt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "actuator"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.2.4", "IEC 60947-5-5", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Regelmaessiger Not-Halt-Test", "Redundantes Sicherheitsrelais", "Selbstueberwachender Sicherheitskreis"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 2),
Category: "safety_function_failure",
Name: "Schutztuer-Monitoring umgangen",
Description: "Das Schutztuer-Positionssignal wird durch einen Fehler oder Manipulation als 'geschlossen' gemeldet, obwohl die Tuer offen ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"sensor", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 14119", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Zwangsöffnender Positionsschalter", "Codierter Sicherheitssensor", "Anti-Tamper-Masssnahmen"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 3),
Category: "safety_function_failure",
Name: "Safe Speed Monitoring fehlt",
Description: "Beim Einrichten im reduzierten Betrieb fehlt eine unabhaengige Geschwindigkeitsueberwachung, so dass der Bediener nicht ausreichend geschuetzt ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62061", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Sicherheitsumrichter mit SLS", "Unabhaengige Drehzahlmessung", "SIL-2-Geschwindigkeitsueberwachung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 4),
Category: "safety_function_failure",
Name: "STO-Funktion (Safe Torque Off) Fehler",
Description: "Die STO-Sicherheitsfunktion schaltet den Antriebsmoment nicht ab, obwohl die Funktion aktiviert wurde, z.B. durch Fehler im Sicherheits-SPS-Ausgang.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"actuator", "controller"},
RegulationReferences: []string{"IEC 61800-5-2", "Maschinenverordnung 2023/1230", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"STO-Pruefung bei Inbetriebnahme", "Pruefzyklus im Betrieb", "Zertifizierter Sicherheitsumrichter"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 5),
Category: "safety_function_failure",
Name: "Muting-Missbrauch bei Lichtvorhang",
Description: "Die Muting-Funktion des Lichtvorhangs wird durch Fehler oder Manipulation zu lange oder unkontrolliert aktiviert, was den Schutz aufhebt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"sensor", "controller"},
RegulationReferences: []string{"IEC 61496-3", "Maschinenverordnung 2023/1230"},
SuggestedMitigations: mustMarshalJSON([]string{"Zeitbegrenztes Muting", "Muting-Lampe und Alarm", "Protokollierung der Muting-Ereignisse"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 6),
Category: "safety_function_failure",
Name: "Zweihand-Taster durch Gegenstand ueberbrueckt",
Description: "Die Zweihand-Betaetigungseinrichtung wird durch ein eingeklemmtes Objekt permanent aktiviert, was den Bediener aus dem Schutzkonzept loest.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"hmi", "controller"},
RegulationReferences: []string{"ISO 13851", "Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Anti-Tie-Down-Pruefung", "Typ-III-Zweihand-Taster", "Regelmaessige Funktionskontrolle"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 7),
Category: "safety_function_failure",
Name: "Sicherheitsrelais-Ausfall ohne Erkennung",
Description: "Ein Sicherheitsrelais versagt unentdeckt (z.B. verklebte Kontakte), sodass der Sicherheitskreis nicht mehr auftrennt.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"controller"},
RegulationReferences: []string{"ISO 13849", "IEC 62061"},
SuggestedMitigations: mustMarshalJSON([]string{"Selbstueberwachung (zwangsgefuehrt)", "Regelmaessiger Testlauf", "Redundantes Relais"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("safety_function_failure", 8),
Category: "safety_function_failure",
Name: "Logic-Solver-Fehler in Sicherheits-SPS",
Description: "Die Sicherheitssteuerung (Safety-SPS) fuehrt sicherheitsrelevante Logik fehlerhaft aus, z.B. durch Speicherfehler oder Prozessorfehler.",
DefaultSeverity: 5,
DefaultProbability: 1,
ApplicableComponentTypes: []string{"controller", "software"},
RegulationReferences: []string{"IEC 61511", "IEC 61508", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"SIL-zertifizierte SPS", "Watchdog", "Selbsttest-Routinen (BIST)"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: environmental_hazard (5 entries)
// ====================================================================
{
ID: hazardUUID("environmental_hazard", 1),
Category: "environmental_hazard",
Name: "Ausfall durch hohe Umgebungstemperatur",
Description: "Hohe Umgebungstemperaturen ueberschreiten die spezifizierten Grenzwerte der Elektronik oder Aktorik und fuehren zu Fehlfunktionen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "sensor"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2"},
SuggestedMitigations: mustMarshalJSON([]string{"Betriebstemperatur-Spezifikation einhalten", "Klimaanlagensystem", "Temperatursensor + Abschaltung"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("environmental_hazard", 2),
Category: "environmental_hazard",
Name: "Ausfall bei Tieftemperatur",
Description: "Sehr tiefe Temperaturen reduzieren die Viskositaet von Hydraulikfluessigkeiten, beeinflussen Elektronik und fuehren zu mechanischen Ausfaellen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"actuator", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2"},
SuggestedMitigations: mustMarshalJSON([]string{"Tieftemperatur-spezifizierte Komponenten", "Heizung im Schaltschrank", "Anlaeufroutine bei Kaeltestart"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("environmental_hazard", 3),
Category: "environmental_hazard",
Name: "Korrosion durch Feuchtigkeit",
Description: "Hohe Luftfeuchtigkeit oder Kondenswasser fuehrt zur Korrosion von Kontakten und Leiterbahnen, was zu Ausfaellen und Isolationsfehlern fuehrt.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"controller", "sensor"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60529"},
SuggestedMitigations: mustMarshalJSON([]string{"IP-Schutz entsprechend der Umgebung", "Belueftung mit Filter", "Regelmaessige Inspektion"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("environmental_hazard", 4),
Category: "environmental_hazard",
Name: "Fehlfunktion durch Vibrationen",
Description: "Mechanische Vibrationen lockern Verbindungen, schuetteln Kontakte auf oder beschaedigen Loetpunkte in Elektronikbaugruppen.",
DefaultSeverity: 4,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "sensor"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2-6"},
SuggestedMitigations: mustMarshalJSON([]string{"Vibrationsdaempfung", "Vergossene Elektronik", "Regelmaessige Verbindungskontrolle"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("environmental_hazard", 5),
Category: "environmental_hazard",
Name: "Kontamination durch Staub oder Fluessigkeiten",
Description: "Staub, Metallspaeene oder Kuehlmittel gelangen in das Gehaeuseinnere und fuehren zu Kurzschluessen, Isolationsfehlern oder Kuehlproblemen.",
DefaultSeverity: 3,
DefaultProbability: 4,
ApplicableComponentTypes: []string{"controller", "hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60529"},
SuggestedMitigations: mustMarshalJSON([]string{"Hohe IP-Schutzklasse", "Dichtungen regelmaessig pruefen", "Ueberdruck im Schaltschrank"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
// ====================================================================
// Category: maintenance_hazard (6 entries)
// ====================================================================
{
ID: hazardUUID("maintenance_hazard", 1),
Category: "maintenance_hazard",
Name: "Wartung ohne LOTO-Prozedur",
Description: "Wartungsarbeiten werden ohne korrekte Lockout/Tagout-Prozedur durchgefuehrt, sodass die Maschine waehrend der Arbeit anlaufen kann.",
DefaultSeverity: 5,
DefaultProbability: 3,
ApplicableComponentTypes: []string{"controller", "software"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3"},
SuggestedMitigations: mustMarshalJSON([]string{"LOTO-Funktion in Software", "Schulung", "Prozedur im Betriebshandbuch"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 2),
Category: "maintenance_hazard",
Name: "Fehlende LOTO-Funktion in Software",
Description: "Die Steuerungssoftware bietet keine Moeglichkeit, die Maschine fuer Wartungsarbeiten sicher zu sperren und zu verriegeln.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3"},
SuggestedMitigations: mustMarshalJSON([]string{"Software-LOTO implementieren", "Wartungsmodus mit Schluessel", "Energiesperrfunktion"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 3),
Category: "maintenance_hazard",
Name: "Wartung bei laufender Maschine",
Description: "Wartungsarbeiten werden an betriebener Maschine durchgefuehrt, weil kein erzwungener Wartungsmodus vorhanden ist.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "controller"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Erzwungenes Abschalten fuer Wartungsmodus", "Schluesselschalter", "Schutzmassnahmen im Wartungsmodus"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 4),
Category: "maintenance_hazard",
Name: "Wartungs-Tool ohne Zugangskontrolle",
Description: "Ein Diagnose- oder Wartungswerkzeug ist ohne Authentifizierung zugaenglich und ermoeglicht die unbeaufsichtigte Aenderung von Sicherheitsparametern.",
DefaultSeverity: 4,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "hmi"},
RegulationReferences: []string{"IEC 62443", "CRA"},
SuggestedMitigations: mustMarshalJSON([]string{"Authentifizierung fuer Wartungs-Tools", "Rollenkonzept", "Audit-Log fuer Wartungszugriffe"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 5),
Category: "maintenance_hazard",
Name: "Unsichere Demontage gefaehrlicher Baugruppen",
Description: "Die Betriebsanleitung beschreibt nicht, wie gefaehrliche Baugruppen (z.B. Hochvolt, gespeicherte Energie) sicher demontiert werden.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"other"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.7.4"},
SuggestedMitigations: mustMarshalJSON([]string{"Detaillierte Demontageanleitung", "Warnhinweise an Geraet", "Schulung des Wartungspersonals"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
{
ID: hazardUUID("maintenance_hazard", 6),
Category: "maintenance_hazard",
Name: "Wiederanlauf nach Wartung ohne Freigabeprozedur",
Description: "Nach Wartungsarbeiten wird die Maschine ohne formelle Freigabeprozedur wieder in Betrieb genommen, was zu Verletzungen bei noch anwesendem Personal fuehren kann.",
DefaultSeverity: 5,
DefaultProbability: 2,
ApplicableComponentTypes: []string{"software", "hmi"},
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3", "ISO 13849"},
SuggestedMitigations: mustMarshalJSON([]string{"Software-Wiederanlauf-Freigabe", "Gefahrenbereich-Pruefung vor Anlauf", "Akustisches Warnsignal vor Anlauf"}),
IsBuiltin: true,
TenantID: nil,
CreatedAt: now,
},
}
}