feat(iace): Phase 5+6 — frontend integration, RAG library search, comprehensive tests
Phase 5 — Frontend Integration:
- components/page.tsx: ComponentLibraryModal with 120 components + 20 energy sources
- hazards/page.tsx: AutoSuggestPanel with 3-column pattern matching review
- mitigations/page.tsx: SuggestMeasuresModal per hazard with 3-level grouping
- verification/page.tsx: SuggestEvidenceModal per mitigation with evidence types

Phase 6 — RAG Library Search:
- Added bp_iace_libraries to AllowedCollections whitelist in rag_handlers.go
- SearchLibrary endpoint: POST /iace/library-search (semantic search across libraries)
- EnrichTechFileSection endpoint: POST /projects/:id/tech-file/:section/enrich
- Created ingest-iace-libraries.sh ingestion script for Qdrant collection

Tests (123 passing):
- tag_taxonomy_test.go: 8 tests for taxonomy entries, domains, essential tags
- controls_library_test.go: 7 tests for measures, reduction types, subtypes
- integration_test.go: 7 integration tests for full match flow and library consistency
- Extended tag_resolver_test.go: 9 new tests for FindByTags and cross-category resolution

Documentation:
- Updated iace.md with Hazard-Matching-Engine, RAG enrichment, and new DB tables

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-16 10:22:49 +01:00

27 KiB
Raw Blame History

IACE — Industrial AI Compliance Engine

Modul: CE-Risikobeurteilung fuer Maschinen mit Software / Firmware / KI Service: ai-compliance-sdk (Go/Gin, Port 8093) Base-URL: GET|POST https://macmini:8093/sdk/v1/iace/...


Ueberblick

Das IACE-Modul unterstuetzt die vollstaendige CE-Konformitaetsbewertung von Maschinen und Systemen mit Software-, Firmware- und KI-Anteilen gemaess:

  • Maschinenverordnung (EU) 2023/1230 (loest Maschinenrichtlinie 2006/42/EG ab)
  • AI Act (EU) 2024/1689 (fuer KI-Systeme in Hochrisikoklassen)
  • CRA (Cyber Resilience Act) (fuer vernetzte Produkte)
  • NIS2 (fuer kritische Infrastrukturen)

Risikomodell (Dual-Modus)

IACE unterstuetzt zwei Betriebsmodi fuer die Risikobewertung:

Legacy-Modus (S×E×P)

Avoidance Formel Beschreibung
0 (Standard) R = S × E × P Backward-kompatibel, kein Avoidance-Faktor

Schwellwerte (Legacy):

Schwelle Level
>= 75 critical
>= 40 high
>= 15 medium
>= 5 low
< 5 negligible

ISO-Modus (S×F×P×A) — ab v2.0

Wenn avoidance >= 1, wird automatisch der ISO-Modus aktiviert:

Formel Beschreibung
R = S × F × P × A Direkte 4-Faktor-Multiplikation (KEIN /3.0)

Faktoren:

Faktor Skala Beschreibung
S (Severity) 15 Schwere des moeglichen Schadens
F (Frequency/Exposure) 15 Haeufigkeit/Dauer der Exposition
P (Probability) 15 Wahrscheinlichkeit des Eintretens
A (Avoidance) 15 Moeglichkeit der Vermeidung (1=leicht, 5=nicht vermeidbar)

Schwellwerte (ISO-Modus):

Schwelle Level Farbe
> 300 not_acceptable Dunkelrot
151300 very_high Dunkelorange
61150 high Rot
2160 medium Gelb
120 low Gruen

ALARP-Akzeptanz

  • residualRisk < 15 → akzeptabel
  • residualRisk < 40 + alle Minderungsschritte verifiziert + Begruendung → akzeptabel (ALARP)
  • residualRisk >= 40 → nicht akzeptabel (blockiert CE-Export)

Schutzmassnahmen-Hierarchie (3-Stufen)

Die Risikobehandlung folgt einer verbindlichen Hierarchie:

Stufe Typ Beschreibung
1 Design Inhaerent sichere Konstruktion (z.B. Begrenzung von Kraeften, Geschwindigkeiten)
2 Schutzeinrichtung Technische Schutzmassnahmen (z.B. Schutzgitter, Lichtvorhang, STO)
3 Information Hinweise, Warnungen, Schulung (z.B. Sicherheitskennzeichnung, Betriebsanleitung)

!!! warning "Hierarchie-Regel" Informationsmassnahmen (Stufe 3) duerfen nicht als alleinige Primaermassnahme akzeptiert werden, wenn Design- oder Schutzmassnahmen technisch moeglich sind. Das System prueft dies automatisch und gibt eine Warnung aus.


Hazard-Library

Die eingebaute Hazard-Library enthaelt 150+ Eintraege in 28 Kategorien. Alle Eintraege verwenden eigene Formulierungen und referenzieren Normen nur als Methodenquelle.

KI/Cyber-Kategorien (12)

Kategorie Beschreibung
false_classification Falsche KI-Klassifikation
timing_error Echtzeit-Verletzungen
data_poisoning Manipulierte Trainingsdaten
model_drift Modell-Verschlechterung
sensor_spoofing Sensor-Manipulation
communication_failure Kommunikationsausfall
unauthorized_access Unberechtigter Zugriff
firmware_corruption Firmware-Beschaedigung
safety_boundary_violation Sicherheitsgrenzwert-Verletzung
mode_confusion Betriebsart-Verwechslung
unintended_bias Unbeabsichtigte Diskriminierung
update_failure Update-Fehler

Software/Hardware-Kategorien (12)

Kategorie Beschreibung
software_fault Race Condition, Stack Overflow, Integer Overflow, Deadlock
hmi_error Falsche Einheit, fehlender Alarm, Quittierung ohne Ursache
mechanical_hazard Quetschen, Scheren, Einziehen, Herabfallende Teile, Instabilitaet
electrical_hazard Elektrischer Schlag, Lichtbogen, Ueberstrom, Erdungsfehler
thermal_hazard Ueberhitzung, Brandgefahr, Einfrieren, Waermestrahlung
emc_hazard EMV-Stoerabstrahlung, ESD, HF-Stoerung
configuration_error Falscher Safety-Param, Hard-coded Credentials, Debug-Mode
safety_function_failure Not-Halt, STO, Schutztuer, Zweihand-Taster
logging_audit_failure Fehlende Protokollierung, Log-Manipulation, Overflow
integration_error Datentyp-Mismatch, Endianness, Buffer Overflow, Heartbeat
environmental_hazard Temperatur, Feuchtigkeit, Vibration, Kontamination
maintenance_hazard LOTO fehlt, Wartung bei laufender Maschine, Wiederanlauf

Physikalische Kategorien (4, ab v2.0)

Kategorie Beschreibung
pneumatic_hydraulic Druckverlust, Druckfreisetzung, Schlauchpeitschen, unerwartete Bewegung
noise_vibration Gehoerschaedigung, Hand-Arm-Vibration, Ganzkoerpervibration
ergonomic Fehlbedienung, Zwangshaltung, Ueberforderung, Repetitive Belastung
material_environmental Staub, Rauch, Daempfe, chemische Exposition, Leckagen

Erweiterte Felder (ab v2.0)

Jeder Hazard-Library-Eintrag enthaelt zusaetzlich:

Feld Typ Beschreibung
default_exposure int (15) Standard-Expositionswert
default_avoidance int (15) Standard-Vermeidbarkeit
typical_causes string[] Typische Ursachen
typical_harm string Typische Schadensfolge
relevant_lifecycle_phases string[] Relevante Lebensphasen
recommended_measures_design string[] Empfohlene Design-Massnahmen
recommended_measures_technical string[] Empfohlene technische Massnahmen
recommended_measures_information string[] Empfohlene Informationsmassnahmen
suggested_evidence string[] Vorgeschlagene Nachweisdokumente
related_keywords string[] Suchbegriffe

Filter: GET /sdk/v1/iace/hazard-library?category=mechanical_hazard&componentType=mechanical


Controls-Library

Die Controls-Library enthaelt 200 Eintraege in 6 Domaenen:

Domaenen-Uebersicht

Domain Eintraege Beschreibung ReductionType
REQ 30 Safety Requirements — HARA, SIL/PL, Traceability design
ARCH 30 Architektur & Design — Redundanz, Fail-Safe, Watchdog design
SWDEV 40 Software-Entwicklung — MISRA-C, Statische Analyse, WCET design/protective
VER 30 Verifikation & Validation — Fault Injection, HIL, SIL-Nachweis design/protective
CYBER 40 OT-Cybersecurity — Netzwerksegmentierung, Signed Updates, SBOM design/protective
DOC 30 Dokumentation & CE-Akte — Technical File, DoC, Betriebsanleitung information

Filter: GET /sdk/v1/iace/controls-library?domain=CYBER&category=unauthorized_access


Schutzmassnahmen-Bibliothek (ab v2.0)

Zusaetzlich zur Controls-Library bietet IACE eine Schutzmassnahmen-Bibliothek mit 160 Eintraegen, kategorisiert nach der 3-Stufen-Hierarchie:

ReductionType Eintraege Beispiele
design ~55 Kraftbegrenzung, Formschluessige Sicherung, Redundante Sensorik
protective ~60 Schutzgitter, Lichtvorhang, STO, Druckbegrenzungsventil
information ~45 Sicherheitskennzeichnung, Betriebsanleitung, Schulungsprogramm

Filter: GET /sdk/v1/iace/protective-measures-library?category=mechanical_hazard


Lebensphasen (25)

Die Risikobeurteilung beruecksichtigt 25 Lebensphasen einer Maschine:

Phase DE EN
transport Transport Transport
storage Lagerung Storage
assembly Montage Assembly
installation Aufstellung Installation
commissioning Inbetriebnahme Commissioning
parameterization Parametrierung Parameterization
setup Einrichten Setup
normal_operation Normalbetrieb Normal Operation
auto_operation Automatikbetrieb Automatic Operation
manual_operation Handbetrieb Manual Operation
teach_mode Teach-Modus Teach Mode
production_start Produktionsstart Production Start
production_stop Produktionsstopp Production Stop
process_monitoring Prozessueberwachung Process Monitoring
cleaning Reinigung Cleaning
inspection Inspektion Inspection
maintenance Wartung Maintenance
calibration Kalibrierung Calibration
repair Reparatur Repair
software_update Software-Update Software Update
remote_maintenance Fernwartung Remote Maintenance
fault_clearing Stoerungsbeseitigung Fault Clearing
changeover Umruestung Changeover
decommissioning Ausserbetriebnahme Decommissioning
disposal Demontage/Entsorgung Dismantling/Disposal

API: GET /sdk/v1/iace/lifecycle-phases


Betroffene Personen (20 Rollen)

Jede Gefaehrdung kann einer oder mehreren betroffenen Personengruppen zugeordnet werden:

Rolle DE EN
operator Bediener Operator
setup_personnel Einrichter Setup Personnel
maintenance_tech Wartungstechniker Maintenance Technician
cleaning_staff Reinigungspersonal Cleaning Staff
supervisor Aufsichtsperson Supervisor
programmer Programmierer/Integrator Programmer/Integrator
trainee Auszubildender Trainee
temp_worker Leiharbeiter Temporary Worker
visitor Besucher Visitor
third_party Dritte/Passanten Third Party/Bystander
transport_personnel Transportpersonal Transport Personnel
commissioning_eng Inbetriebnahme-Ingenieur Commissioning Engineer
quality_inspector Qualitaetspruefer Quality Inspector
safety_officer Sicherheitsbeauftragter Safety Officer
electrical_tech Elektrofachkraft Electrical Technician
it_admin IT-Administrator IT Administrator
remote_operator Fernbediener Remote Operator
emergency_responder Ersthelfer/Rettungskraft Emergency Responder
contractor Fremdfirma-Mitarbeiter Contractor
disabled_person Person mit Einschraenkung Person with Disability

API: GET /sdk/v1/iace/roles


Nachweistypen (50 in 7 Kategorien)

Fuer die Verifikation stehen 50 Nachweistypen zur Auswahl:

Kategorie Beispiele
Konstruktion Risikobeurteilung, Sicherheitskonzept, Schaltplan, Pneumatikplan
Berechnung Festigkeitsberechnung, Thermische Simulation, FMEA
Pruefung Funktionspruefung, Druckpruefung, EMV-Messung, Isolationspruefung
Zertifizierung Baumuster-Pruefbescheinigung, SIL/PL-Zertifikat, CE-Konformitaetserklaerung
Software Code-Review-Protokoll, Statische Analyse, Unit-Test-Report, Penetrationstest
Betrieb Betriebsanleitung, Wartungsplan, Schulungsnachweis, Notfallplan
Ueberwachung Inspektionsbericht, Kalibrierprotokoll, Audit-Report, Maengelprotokoll

API: GET /sdk/v1/iace/evidence-types?category=pruefung


Verifikationsmethoden (10)

Methode Beschreibung
design_review Systematische Pruefung von Konstruktionsunterlagen
calculation Rechnerischer Nachweis (Festigkeit, Thermik, SIL)
test_report Pruefbericht aus Labor- oder Feldversuchen
validation Nachweis der Gebrauchstauglichkeit unter realen Bedingungen
electrical_test Isolationsmessung, Schutzleiter, Spannungspruefung
software_test Unit-Test, Integrationstest, statische Analyse
penetration_test Sicherheitstest der IT/OT-Infrastruktur
acceptance_protocol Formales Abnahmeprotokoll mit Checkliste
user_test Anwendertest unter realistischen Einsatzbedingungen
documentation_release Formale Freigabe von Dokumenten und Anleitungen

API-Endpunkte (30+)

Libraries & Referenzdaten (projektunabhaengig)

Methode Pfad Beschreibung
GET /sdk/v1/iace/hazard-library Alle Gefaehrdungen (150+)
GET /sdk/v1/iace/controls-library Alle Controls (200)
GET /sdk/v1/iace/protective-measures-library Schutzmassnahmen-Bibliothek (160)
GET /sdk/v1/iace/lifecycle-phases 25 Lebensphasen (DE/EN)
GET /sdk/v1/iace/roles 20 betroffene Personengruppen (DE/EN)
GET /sdk/v1/iace/evidence-types 50 Nachweistypen in 7 Kategorien

Projektmanagement

Methode Pfad Beschreibung
POST /sdk/v1/iace/projects Neues Projekt erstellen
GET /sdk/v1/iace/projects Alle Projekte auflisten
GET /sdk/v1/iace/projects/:id Projekt-Details
PUT /sdk/v1/iace/projects/:id Projekt aktualisieren
DELETE /sdk/v1/iace/projects/:id Projekt archivieren

Onboarding

Methode Pfad Beschreibung
POST /sdk/v1/iace/projects/:id/init-from-profile Projekt aus Company-Profile initialisieren
POST /sdk/v1/iace/projects/:id/completeness-check 25-Gates-Pruefung

Komponenten

Methode Pfad Beschreibung
POST /sdk/v1/iace/projects/:id/components Komponente hinzufuegen
GET /sdk/v1/iace/projects/:id/components Alle Komponenten
PUT /sdk/v1/iace/projects/:id/components/:cid Komponente aktualisieren
DELETE /sdk/v1/iace/projects/:id/components/:cid Komponente loeschen

Klassifizierung

Methode Pfad Beschreibung
POST /sdk/v1/iace/projects/:id/classify Alle Regulierungen klassifizieren
GET /sdk/v1/iace/projects/:id/classifications Klassifizierungen abrufen
POST /sdk/v1/iace/projects/:id/classify/:regulation Einzelne Regulierung

Gefaehrdungen & Risikobewertung

Methode Pfad Beschreibung
POST /sdk/v1/iace/projects/:id/hazards Gefaehrdung anlegen
GET /sdk/v1/iace/projects/:id/hazards Alle Gefaehrdungen
PUT /sdk/v1/iace/projects/:id/hazards/:hid Gefaehrdung aktualisieren
POST /sdk/v1/iace/projects/:id/hazards/suggest KI-gestuetzte Vorschlaege
POST /sdk/v1/iace/projects/:id/hazards/:hid/assess Risikobewertung (SEPA)
POST /sdk/v1/iace/projects/:id/hazards/:hid/reassess Neubewertung nach Minderung
GET /sdk/v1/iace/projects/:id/risk-summary Aggregierte Risikouebersicht
POST /sdk/v1/iace/projects/:id/validate-mitigation-hierarchy Hierarchie-Pruefung (3-Stufen)

Minderung & Verifikation

Methode Pfad Beschreibung
POST /sdk/v1/iace/projects/:id/hazards/:hid/mitigations Massnahme anlegen
GET /sdk/v1/iace/projects/:id/hazards/:hid/mitigations Alle Massnahmen
PUT /sdk/v1/iace/projects/:id/hazards/:hid/mitigations/:mid Massnahme aktualisieren
POST /sdk/v1/iace/projects/:id/verification-plans Verifikationsplan erstellen
GET /sdk/v1/iace/projects/:id/verification-plans Alle Plaene
PUT /sdk/v1/iace/projects/:id/verification-plans/:vid Plan aktualisieren

CE-Technische Akte

Methode Pfad Beschreibung
GET /sdk/v1/iace/projects/:id/tech-file Technische Akte abrufen
POST /sdk/v1/iace/projects/:id/tech-file/generate Akte generieren
GET /sdk/v1/iace/projects/:id/tech-file/export Akte exportieren (PDF/Markdown)
PUT /sdk/v1/iace/projects/:id/tech-file/sections/:sid Abschnitt aktualisieren

Post-Market Monitoring

Methode Pfad Beschreibung
POST /sdk/v1/iace/projects/:id/monitoring-events Ereignis protokollieren
GET /sdk/v1/iace/projects/:id/monitoring-events Alle Ereignisse

Audit-Trail

Methode Pfad Beschreibung
GET /sdk/v1/iace/projects/:id/audit-trail Unveraenderliches Audit-Log

Completeness Gates (25)

Das Modul prueft 25 Vollstaendigkeitstore vor dem CE-Export:

Gate Kategorie Pflicht
G01 Projekt-Grunddaten vollstaendig Required
G02 CE-Markierungsziel definiert Required
G03 Mind. 1 Komponente erfasst Required
G04 Regulatorische Klassifizierung abgeschlossen Required
G05 HARA-Dokument vorhanden (Evidence) Required
G06 Mind. 1 Gefaehrdung identifiziert Required
G07 Alle Gefaehrdungen bewertet Required
G08 Kein Restrisiko > critical ohne Akzeptanz Required
G09 Mind. 1 Minderungsmassnahme je Gefaehrdung Required
G10 Minderungsmassnahmen verifiziert Required
G11 Verifikationsplan vorhanden Required
G12 SIL/PL-Dokumentation (Evidence) Required
G13 Technische Akte generiert Required
G14 Konformitaetserklaerung bereit Required
G15 Betriebsanleitung vorhanden Required
G16 Wartungsanleitung vorhanden Recommended
G17 Post-Market Monitoring aktiv Recommended
G18 Cybersecurity-Massnahmen dokumentiert Recommended
G19 AI-spezifische Anforderungen erfuellt Recommended (bei AI)
G20 Kalibrierprotokolle vorhanden Recommended
G21 SBOM generiert Optional
G22 Penetrationstest durchgefuehrt Optional
G23 EMV-Pruefung dokumentiert Optional
G24 Lebenszyklusplan vorhanden Optional
G25 Monitoring-Ereignisse protokolliert Optional

Completeness Score: (passed_required/total_required)*80 + (passed_recommended/total_recommended)*15 + (passed_optional/total_optional)*5


CE RAG-Corpus

Die folgenden 15 Dokumente werden via scripts/ingest-ce-corpus.sh ingestiert:

Collection: bp_compliance_ce

# Dokument Kategorie Lizenz
1 Machinery Regulation (EU) 2023/1230 ce_machinery EU Public Law
2 Machinery Directive 2006/42/EC ce_machinery EU Public Law
3 Low Voltage Directive 2014/35/EU ce_electrical EU Public Law
4 EMC Directive 2014/30/EU ce_emc EU Public Law
5 Radio Equipment Directive 2014/53/EU ce_radio EU Public Law
6 AI Act (EU) 2024/1689 ce_ai EU Public Law
7 EC Guide to the Machinery Directive ce_machinery_guidance EU Public
8 NIST SP 800-218 (SSDF) ce_software_safety US Gov Public Domain
9 NIST AI RMF 1.0 ce_ai_safety US Gov Public Domain
10 ENISA Guidelines for Securing the IoT ce_ot_cybersecurity EU Public
12 NASA Software Safety Guidebook ce_software_safety US Gov Public Domain
13 OWASP Top 10 (2021) ce_software_security CC BY-SA 4.0
15 MITRE CWE Top 25 (2023) ce_software_weaknesses MIT

Collection: bp_compliance_datenschutz

# Dokument Kategorie Lizenz
11 ENISA Securing Machine Learning Algorithms ai_cybersecurity EU Public
14 OECD AI Principles ai_governance OECD Public

Ingest-Script ausfuehren

# Auf dem Mac Mini:
bash ~/Projekte/breakpilot-compliance/scripts/ingest-ce-corpus.sh

# Nur bestimmte Phase:
bash .../ingest-ce-corpus.sh --only ce
bash .../ingest-ce-corpus.sh --only datenschutz
bash .../ingest-ce-corpus.sh --skip-download --only verify

# Ergebnis pruefen:
curl -sk https://macmini:8093/sdk/v1/iace/hazard-library | python3 -c "import sys,json; print(json.load(sys.stdin)['total'])"
curl -sk https://macmini:8093/sdk/v1/iace/controls-library | python3 -c "import sys,json; print(json.load(sys.stdin)['total'])"

Beispiel: Risikobewertung

Legacy-Modus (A=0)

curl -sk -X POST https://macmini:8093/sdk/v1/iace/projects/{id}/hazards/{hid}/assess \
  -H "Content-Type: application/json" \
  -H "X-Tenant-Id: <tenant-uuid>" \
  -d '{"severity": 5, "exposure": 3, "probability": 3, "avoidance": 0}'

Ergebnis: R = 5 × 3 × 3 = 45high

ISO-Modus (A >= 1)

curl -sk -X POST https://macmini:8093/sdk/v1/iace/projects/{id}/hazards/{hid}/assess \
  -H "Content-Type: application/json" \
  -H "X-Tenant-Id: <tenant-uuid>" \
  -d '{
    "severity": 5,
    "exposure": 3,
    "probability": 3,
    "avoidance": 4,
    "control_maturity": 2,
    "control_coverage": 0.6,
    "test_evidence_strength": 0.5,
    "acceptance_justification": "ALARP: STO implementiert und verifiziert"
  }'

Ergebnis: R = 5 × 3 × 3 × 4 = 180very_high (ISO-Schwellwerte)


Beispiel: Controls-Library abfragen

# Alle CYBER-Controls
curl -sk "https://macmini:8093/sdk/v1/iace/controls-library?domain=CYBER" \
  | python3 -c "import sys,json; d=json.load(sys.stdin); print(f'{d[\"total\"]} Controls')"

# Controls fuer software_fault-Kategorie
curl -sk "https://macmini:8093/sdk/v1/iace/controls-library?category=software_fault" \
  | python3 -m json.tool | head -40

Hazard-Matching-Engine

Die Pattern Engine automatisiert die Ableitung von Gefaehrdungen, Schutzmassnahmen und Nachweisen aus der Maschinenkonfiguration.

Komponentenbibliothek (120 Eintraege)

# Alle Komponenten abrufen
curl -sk "https://macmini:8093/sdk/v1/iace/component-library" | python3 -c \
  "import sys,json; d=json.load(sys.stdin); print(f'{d[\"total\"]} Komponenten in {len(set(c[\"category\"] for c in d[\"components\"]))} Kategorien')"

# Nach Kategorie filtern
curl -sk "https://macmini:8093/sdk/v1/iace/component-library?category=mechanical"
Kategorie IDs Anzahl Beispiele
mechanical C001-C020 20 Roboterarm, Greifer, Foerderband
structural C021-C030 10 Maschinenrahmen, Schutzgehaeuse
drive C031-C040 10 Elektromotor, Servomotor
hydraulic C041-C050 10 Hydraulikpumpe, -zylinder
pneumatic C051-C060 10 Pneumatikzylinder, Kompressor
electrical C061-C070 10 Schaltschrank, Stromversorgung
control C071-C080 10 SPS, Sicherheits-SPS, HMI
sensor C081-C090 10 Positionssensor, Kamerasystem
actuator C091-C100 10 Magnetventil, Linearantrieb
safety C101-C110 10 Not-Halt, Lichtgitter
it_network C111-C120 10 Switch, Router, Firewall

Energiequellen (20 Eintraege)

curl -sk "https://macmini:8093/sdk/v1/iace/energy-sources"

Tag-Taxonomie (~85 Tags)

Domaene Anzahl Beispiele
component ~30 moving_part, rotating_part, high_voltage, networked, has_ai
energy ~15 kinetic, rotational, electrical_energy, hydraulic_pressure
hazard ~20 crush_risk, shear_risk, electric_shock_risk, cyber_risk
measure ~10 guard_measure, interlock_measure, software_safety_measure
evidence ~10 design_evidence, test_evidence, cyber_evidence
# Alle Tags einer Domaene
curl -sk "https://macmini:8093/sdk/v1/iace/tags?domain=component"

Hazard Patterns (44 Regeln)

Jedes Pattern definiert required_component_tags (AND), required_energy_tags (AND) und excluded_component_tags (NOT). Die Engine prueft alle Patterns gegen die aufgeloesten Tags der Projektkomponenten.

# Patterns auflisten
curl -sk "https://macmini:8093/sdk/v1/iace/hazard-patterns" | python3 -c \
  "import sys,json; d=json.load(sys.stdin); print(f'{d[\"total\"]} Patterns')"

Pattern-Matching Workflow

# 1. Pattern-Matching ausfuehren
curl -sk -X POST "https://macmini:8093/sdk/v1/iace/projects/{id}/match-patterns" \
  -H "Content-Type: application/json" \
  -d '{"component_library_ids": ["C001","C071"], "energy_source_ids": ["EN01","EN07"]}'

# 2. Ergebnisse uebernehmen
curl -sk -X POST "https://macmini:8093/sdk/v1/iace/projects/{id}/apply-patterns" \
  -H "Content-Type: application/json" \
  -d '{"accepted_hazards": [...], "accepted_measures": [...], "accepted_evidence": [...]}'

# 3. Pro-Hazard Massnahmen vorschlagen
curl -sk -X POST "https://macmini:8093/sdk/v1/iace/projects/{id}/hazards/{hid}/suggest-measures"

# 4. Pro-Massnahme Nachweise vorschlagen
curl -sk -X POST "https://macmini:8093/sdk/v1/iace/projects/{id}/mitigations/{mid}/suggest-evidence"

RAG-Anreicherung (Phase 6)

IACE-Bibliotheken (Hazards, Komponenten, Energiequellen, Massnahmen, Nachweise) sind als RAG-Corpus in Qdrant verfuegbar (bp_iace_libraries).

# Semantische Suche in der IACE-Bibliothek
curl -sk -X POST "https://macmini:8093/sdk/v1/iace/library-search" \
  -H "Content-Type: application/json" \
  -d '{"query": "Quetschgefahr Roboterarm", "top_k": 5}'

# Tech-File-Abschnitt mit RAG-Kontext anreichern
curl -sk -X POST "https://macmini:8093/sdk/v1/iace/projects/{id}/tech-file/risk_assessment_report/enrich"

Ingestion:

# IACE-Bibliotheken in Qdrant ingestieren (auf Mac Mini)
bash ~/Projekte/breakpilot-compliance/scripts/ingest-iace-libraries.sh

Datenbank-Tabellen

Tabelle Beschreibung
iace_projects CE-Projekte
iace_components System-Komponenten
iace_regulatory_classifications Regulierungsklassifizierungen
iace_hazard_library Benutzerdefinierte Hazard-Templates
iace_hazards Projektspezifische Gefaehrdungen (inkl. lifecycle_phase, affected_person, trigger_event)
iace_risk_assessments Risikobewertungen (Legacy S×E×P + ISO S×F×P×A)
iace_mitigations Minderungsmassnahmen
iace_verification_plans Verifikationsplaene
iace_evidence Nachweise (Uploads)
iace_tech_file_sections CE-Akte-Abschnitte
iace_monitoring_events Post-Market-Ereignisse
iace_audit_trail Unveraenderbares Audit-Log
iace_lifecycle_phases 25 Lebensphasen (DE/EN)
iace_roles 20 betroffene Personengruppen (DE/EN)
iace_evidence_types 50 Nachweistypen in 7 Kategorien
iace_component_library 120 Maschinenkomponenten (C001-C120)
iace_energy_sources 20 Energiequellen (EN01-EN20)
iace_pattern_results Audit-Trail fuer Pattern-Matching

Rechtlicher Hinweis — Normenreferenz

!!! warning "Urheberrecht bei Normen" Saemtliche Inhalte des IACE-Moduls (Gefaehrdungsbibliothek, Schutzmassnahmen-Katalog, Risikomodell, Lebensphasen, Rollen) sind eigenstaendig formuliert. Normen wie ISO 12100, DIN EN 62443, IEC 61508 etc. werden ausschliesslich als Methodenreferenz in den Metadaten gefuehrt (z.B. "methodology_reference": "ISO 12100").

Es wird **kein normativer Text** reproduziert — keine Tabellen, Risikoklassifikationen,
Prozesstexte oder Checklisten aus Normen. Dies ist konform mit §51 UrhG (Zitatrecht).

Fuer die Anwendung der vollstaendigen Normen muss die jeweilige Norm separat
ueber DIN Media (beuth.de) oder ISO erworben werden.

Beispiel fuer konforme Normenreferenz in generierten Dokumenten:

Die Risikobeurteilung wurde unter Beruecksichtigung allgemein anerkannter Methoden der Maschinensicherheit durchgefuehrt (u.a. angelehnt an ISO 12100).