Systematic refactoring of all hazard_patterns_*.go files: - Removed lifecycle phase words from NameDE and ScenarioDE (67 fixes across 20 files) - Phases belong in ApplicableLifecycles, not in text - "bei Wartung/Reinigung/Montage/..." removed from names - Scenarios rewritten to be phase-neutral - Lifecycle-specific concepts preserved when they define the hazard (e.g. LOTO, Betriebsartenwahlschalter) Rule: Gefaehrdung + Szenario NEUTRAL, Lebensphasen SEPARAT. Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
83 lines
4.9 KiB
Go
83 lines
4.9 KiB
Go
package iace
|
|
|
|
// builtinElectricalPatterns returns HP011-HP015: electrical hazard patterns.
|
|
func builtinElectricalPatterns() []HazardPattern {
|
|
return []HazardPattern{
|
|
{
|
|
ID: "HP011", NameDE: "Stromschlaggefahr durch Hochspannung", NameEN: "Electric shock risk from high voltage",
|
|
RequiredComponentTags: []string{"high_voltage"},
|
|
RequiredEnergyTags: []string{"electrical_energy"},
|
|
GeneratedHazardCats: []string{"electrical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M061", "M062", "M063", "M121"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E04", "E10"},
|
|
Priority: 95,
|
|
ScenarioDE: "Person beruehrt spannungsfuehrende Teile durch defekte Isolation oder ungesicherten Zugang.",
|
|
TriggerDE: "Direktes oder indirektes Beruehren spannungsfuehrender Leiter ueber 50 V AC / 120 V DC.",
|
|
HarmDE: "Stromschlag, Herzkammerflimmern, Verbrennungen, Todesfolge bei Hochspannung.",
|
|
AffectedDE: "Wartungspersonal, Elektrofachkraefte, Bedienpersonal",
|
|
ZoneDE: "Schaltschrank, Klemmenkasten, Motoranschluss, Frequenzumrichter",
|
|
DefaultSeverity: 5, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP012", NameDE: "Gefahr durch elektrische Komponenten", NameEN: "Risk from electrical components",
|
|
RequiredComponentTags: []string{"electrical_part"},
|
|
RequiredEnergyTags: []string{"electrical_energy"},
|
|
GeneratedHazardCats: []string{"electrical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M061", "M064", "M121"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E04", "E10"},
|
|
Priority: 85,
|
|
ScenarioDE: "Elektrische Bauteile (Motoren, Netzteile, Schaltgeraete) stellen bei Defekt oder offenem Gehaeuse eine Beruehrungsgefahr dar.",
|
|
TriggerDE: "Isolationsfehler, offene Gehaeuse oder beschaedigte Leitungen fuehren zu Spannungsverschleppung.",
|
|
HarmDE: "Stromschlag, lokale Verbrennungen, Muskelverkrampfung.",
|
|
AffectedDE: "Bedienpersonal, Wartungspersonal",
|
|
ZoneDE: "Motorgehaeuse, Anschlussklemmen, Netzteile, Kabelkanaele",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP013", NameDE: "Gefahr durch gespeicherte elektrische Energie", NameEN: "Stored electrical energy risk",
|
|
RequiredComponentTags: []string{"stored_energy"},
|
|
RequiredEnergyTags: []string{"electrical_energy"},
|
|
GeneratedHazardCats: []string{"electrical_hazard"},
|
|
SuggestedMeasureIDs: []string{"M062", "M063", "M121", "M123"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E10"},
|
|
Priority: 85,
|
|
ScenarioDE: "Kondensatoren, Batterien oder Frequenzumrichter halten nach Abschalten gefaehrliche Restspannung.",
|
|
TriggerDE: "Wartungsarbeiten am Geraet ohne Warten der Entladezeit oder ohne Spannungsfreiheitspruefung.",
|
|
HarmDE: "Stromschlag, Verbrennungen durch Lichtbogen, Explosion bei Lithium-Akkus.",
|
|
AffectedDE: "Elektrofachkraefte, Wartungspersonal",
|
|
ZoneDE: "Zwischenkreiskondensatoren, Batteriefaecher, USV-Anlagen",
|
|
DefaultSeverity: 4, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP014", NameDE: "Kurzschluss-/Lichtbogengefahr", NameEN: "Short circuit / arc flash risk",
|
|
RequiredComponentTags: []string{"high_voltage", "electrical_part"},
|
|
RequiredEnergyTags: []string{},
|
|
GeneratedHazardCats: []string{"electrical_hazard", "thermal_hazard"},
|
|
SuggestedMeasureIDs: []string{"M061", "M065", "M131"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E04", "E10"},
|
|
Priority: 90,
|
|
ScenarioDE: "Kurzschluss erzeugt Lichtbogen mit extremer Hitze und Druckwelle im Schaltschrank.",
|
|
TriggerDE: "Werkzeug ueberbrueckt spannungsfuehrende Teile, Isolationsversagen oder Verschmutzung unter Spannung.",
|
|
HarmDE: "Schwere Verbrennungen (2./3. Grad), Augenverletzung durch UV-Strahlung, Hoerschaden durch Druckwelle.",
|
|
AffectedDE: "Elektrofachkraefte, Personen in unmittelbarer Naehe",
|
|
ZoneDE: "Schaltschrank-Innenraum, Sammelschienen, Leistungsschuetze",
|
|
DefaultSeverity: 5, DefaultExposure: 2,
|
|
},
|
|
{
|
|
ID: "HP015", NameDE: "EMV-Stoerungsgefahr", NameEN: "EMC interference risk",
|
|
RequiredComponentTags: []string{"electrical_part"},
|
|
RequiredEnergyTags: []string{"electromagnetic"},
|
|
GeneratedHazardCats: []string{"emc_hazard"},
|
|
SuggestedMeasureIDs: []string{"M066", "M121"},
|
|
SuggestedEvidenceIDs: []string{"E01", "E10"},
|
|
Priority: 70,
|
|
ScenarioDE: "Elektromagnetische Stoerungen beeinflussen Steuerungssignale und loesen unerwartete Maschinenbewegungen aus.",
|
|
TriggerDE: "Nahes Hochfrequenzgeraet, mangelnde Schirmung oder fehlende Filterung stoert Steuersignale.",
|
|
HarmDE: "Fehlausloesung von Aktoren, unerwartete Bewegung, Ausfall von Sicherheitsfunktionen.",
|
|
AffectedDE: "Bedienpersonal, Personen im Maschinenbereich",
|
|
ZoneDE: "Gesamte Maschinenumgebung, insbesondere Signalleitungen und Sensorik",
|
|
DefaultSeverity: 3, DefaultExposure: 2,
|
|
},
|
|
}
|
|
}
|