ff100c1cb8
Adds a jurisdiction-cross-reference layer to the norms library. Each entry
maps an ISO/IEC/EN norm to its identifier in DIN (DE), ANSI/NFPA/UL/OSHA (US),
GB (CN), and JIS (JP), with explicit Relation (identical/equivalent/partial/
superseded_by/supersedes) and Confidence (verified/high/medium/low) fields.
Batch 1 covers IDs 1-100 in load order:
- 1a (50): A-norms + B1-norms + early B2-norms (ergonomics, vibration, noise)
- 1b (50): remaining B2 (ATEX, EMC, cybersec) + first C-norms (presses,
robots, conveyors, plastics, woodworking)
These are the foundational, internationally harmonized standards with the
strongest verified mappings (ISO 12100 ~> GB 15706 ~> JIS B 9700, EN 60204-1
~> NFPA 79 ~> GB 5226.1 ~> JIS B 9960-1, etc.).
API:
- GET /iace/norms-library?include_crossref=true → inline crossref
- GET /iace/norms-library/:id/crossref → single norm lookup
- GET /iace/norms-library/crossref → bulk dump
Strategic context: enables dual-use CE/US/CN/JP tech files without
re-authoring, and addresses the "Norm Translation Matrix" gap that the
US-export strategy memory entry calls out. 6 batches remaining (~571 norms)
to reach full library coverage.
Tests: 6 new tests; all pass via `go test -vet=off ./internal/iace/`.
(vet=off needed only to bypass an unrelated pre-existing typo in
document_export_sources.go.)
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
453 lines
23 KiB
Go
453 lines
23 KiB
Go
package iace
|
|
|
|
// Cross-reference matrix — Batch 1b (IDs 51-100 in norms_library.go load order).
|
|
// Covers remaining B2-norms (ATEX, EMC, ergonomics, cybersecurity) and the
|
|
// first wave of C-norms (presses, robots, conveyors, plastics machinery).
|
|
// C-norm international equivalents are less harmonized than A/B norms;
|
|
// confidence levels reflect this.
|
|
|
|
func init() {
|
|
registerCrossRefs(batch1bCrossRefs())
|
|
}
|
|
|
|
// batch1bCrossRefs contains entries 51-100.
|
|
func batch1bCrossRefs() []NormCrossRef {
|
|
return []NormCrossRef{
|
|
{
|
|
NormID: "EN-1127-1", BatchID: "1b",
|
|
Notes: "Explosive atmospheres — explosion prevention and protection (ATEX).",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 1127-1:2019-10", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-NFPA", Identifier: "NFPA 69:2024 (Explosion Prevention Systems)", Relation: "partial", Confidence: "high"},
|
|
{Region: "US-NFPA", Identifier: "NFPA 654 (Combustible Dust)", Relation: "partial", Confidence: "high"},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1910.307 (Hazardous (classified) locations)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-13463-1", BatchID: "1b",
|
|
Notes: "Non-electrical equipment for explosive atmospheres. Largely superseded by EN ISO 80079-36/-37.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 13463-1:2009-07 (withdrawn 2018)", Relation: "superseded_by", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "ISO 80079-36:2016 / ISO 80079-37:2016", Relation: "supersedes", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "ISO-4021", BatchID: "1b",
|
|
Notes: "Hydraulic fluid power — extraction of fluid samples for contamination analysis.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN ISO 4021:2017-09", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-982", BatchID: "1b",
|
|
Notes: "Hydraulic safety — withdrawn, replaced by EN ISO 4413.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 982:1996+A1:2008 (withdrawn 2010)", Relation: "superseded_by", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "ISO 4413:2010", Relation: "supersedes", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-983", BatchID: "1b",
|
|
Notes: "Pneumatic safety — withdrawn, replaced by EN ISO 4414.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 983:1996+A1:2008 (withdrawn 2010)", Relation: "superseded_by", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "ISO 4414:2010", Relation: "supersedes", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "ISO-14118", BatchID: "1b",
|
|
Notes: "Prevention of unexpected start-up (formerly EN 1037).",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN ISO 14118:2018-06", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1910.147 (LOTO)", Relation: "partial", Confidence: "high"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/ASSP Z244.1-2016 (Lockout/Tagout)", Relation: "equivalent", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB/T 19670-2005", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-574", BatchID: "1b",
|
|
Notes: "Two-hand control devices — functional aspects and design principles.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN ISO 13851:2019-12 (replaces EN 574)", Relation: "superseded_by", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "ISO 13851:2019", Relation: "supersedes", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B11.19-2019 §10 (Two-Hand Control)", Relation: "partial", Confidence: "high"},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1910.217(c)(3)(iii)(c) (Press Two-Hand Trip)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "IEC-62443-4-2", BatchID: "1b",
|
|
Notes: "Industrial Automation and Control Systems (IACS) cybersecurity — component requirements.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN IEC 62443-4-2:2020-08", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/ISA-62443-4-2-2018", Relation: "identical", Confidence: "verified"},
|
|
{Region: "CN-GB", Identifier: "GB/T 33009.1-2016 (IACS Cybersecurity)", Relation: "partial", Confidence: "medium"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "IEC-62443-3-3", BatchID: "1b",
|
|
Notes: "IACS cybersecurity — system security requirements and security levels.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN IEC 62443-3-3:2020-08", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/ISA-62443-3-3-2013", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-12198-1", BatchID: "1b",
|
|
Notes: "Safety of machinery — assessment and reduction of risks arising from radiation.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 12198-1:2009-07", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-626-1", BatchID: "1b",
|
|
Notes: "Reduction of risk to health from hazardous substances emitted by machinery — Part 1: principles.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 626-1:2008-09", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1910.1000 (Air Contaminants PELs)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-626-2", BatchID: "1b",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 626-2:2008-09 (Verification procedure)", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-61000-6-1", BatchID: "1b",
|
|
Notes: "EMC — Generic immunity for residential, commercial, light-industry environments.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61000-6-1:2019-11 (VDE 0839-6-1)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "IEC 61000-6-1:2016", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-FCC", Identifier: "47 CFR Part 15 Subpart B", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB/T 17799.1-2017", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-61000-6-2", BatchID: "1b",
|
|
Notes: "EMC — Generic immunity for industrial environments.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61000-6-2:2019-11 (VDE 0839-6-2)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "IEC 61000-6-2:2016", Relation: "identical", Confidence: "verified"},
|
|
{Region: "CN-GB", Identifier: "GB/T 17799.2-2003", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-61000-6-3", BatchID: "1b",
|
|
Notes: "EMC — Generic emission for residential/commercial environments.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61000-6-3:2022-04 (VDE 0839-6-3)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "IEC 61000-6-3:2020", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-FCC", Identifier: "47 CFR Part 15 Subpart B", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 17799.3-2012", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-61000-6-4", BatchID: "1b",
|
|
Notes: "EMC — Generic emission for industrial environments.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61000-6-4:2020-09 (VDE 0839-6-4)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "IEC 61000-6-4:2018", Relation: "identical", Confidence: "verified"},
|
|
{Region: "CN-GB", Identifier: "GB 17799.4-2012", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-62353", BatchID: "1b",
|
|
Notes: "Medical electrical equipment — recurrent test and test after repair.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 62353:2015-10 (VDE 0751-1)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-NFPA", Identifier: "NFPA 99:2024 §10 (Medical Equipment)", Relation: "partial", Confidence: "medium"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-50110-1", BatchID: "1b",
|
|
Notes: "Operation of electrical installations — general requirements.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 50110-1:2014-02 (VDE 0105-100)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-NFPA", Identifier: "NFPA 70E:2024 (Electrical Safety in the Workplace)", Relation: "partial", Confidence: "high"},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1910 Subpart S (Electrical)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-60079-0", BatchID: "1b",
|
|
Notes: "Explosive atmospheres (ATEX) — equipment, general requirements.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN IEC 60079-0:2019-09 (VDE 0170-1)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "IEC 60079-0:2017", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-UL", Identifier: "UL 60079-0:2020", Relation: "equivalent", Confidence: "high"},
|
|
{Region: "US-FM", Identifier: "FM 3600 (HazLoc Equipment General Requirements)", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 3836.1-2021", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-60079-1", BatchID: "1b",
|
|
Notes: "Equipment protection by flameproof enclosures 'd'.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 60079-1:2014-06 (VDE 0170-5)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-UL", Identifier: "UL 60079-1:2020", Relation: "equivalent", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 3836.2-2021", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-60079-7", BatchID: "1b",
|
|
Notes: "Equipment protection by increased safety 'e'.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 60079-7:2016-04 (VDE 0170-6)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-UL", Identifier: "UL 60079-7:2017", Relation: "equivalent", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 3836.3-2021", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-60079-11", BatchID: "1b",
|
|
Notes: "Equipment protection by intrinsic safety 'i'.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 60079-11:2012-06 (VDE 0170-7)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-UL", Identifier: "UL 60079-11:2014", Relation: "equivalent", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 3836.4-2021", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-60079-14", BatchID: "1b",
|
|
Notes: "Electrical installations design, selection, and erection in hazardous areas.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 60079-14:2014-10 (VDE 0165-1)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-NFPA", Identifier: "NFPA 70 (NEC) Articles 500-506 (Hazardous Locations)", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB/T 3836.15-2017", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-60079-17", BatchID: "1b",
|
|
Notes: "Inspection and maintenance of EX installations.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 60079-17:2014-10 (VDE 0165-10-1)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "CN-GB", Identifier: "GB/T 3836.16-2017", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "ISO-7000", BatchID: "1b",
|
|
Notes: "Graphical symbols for use on equipment — registered symbols.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 80416 / DIN ISO 7000", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI Z535.3 (Criteria for Safety Symbols)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "ISO-7010", BatchID: "1b",
|
|
Notes: "Graphical symbols — safety colours and signs, registered safety signs.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN ISO 7010:2020-07", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI Z535.2 (Environmental and Facility Safety Signs)", Relation: "partial", Confidence: "high", Notes: "US uses different colour/format conventions (signal words)."},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1910.145 (Specifications for accident prevention signs and tags)", Relation: "partial", Confidence: "high"},
|
|
{Region: "JP-JIS", Identifier: "JIS Z 9098:2016", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-61310-1", BatchID: "1b",
|
|
Notes: "Indication, marking and actuation — Part 1: visual, auditory and tactile signals.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN IEC 61310-1:2017-08 (VDE 0113-101)", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-61310-2", BatchID: "1b",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN IEC 61310-2:2008-09 (Marking)", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-61310-3", BatchID: "1b",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61310-3:2008-09 (Actuator location/operation)", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "IEC-61511-1", BatchID: "1b",
|
|
Notes: "Functional safety — safety instrumented systems for the process industry sector.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61511-1:2018-12 (VDE 0810-1)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/ISA-61511-1-2018", Relation: "identical", Confidence: "verified"},
|
|
{Region: "CN-GB", Identifier: "GB/T 21109.1-2007", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "IEC-61511-2", BatchID: "1b",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61511-2:2018-12 (VDE 0810-2)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/ISA-61511-2-2018", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "IEC-61511-3", BatchID: "1b",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61511-3:2018-12 (VDE 0810-3)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/ISA-61511-3-2018", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-692", BatchID: "1b",
|
|
Notes: "Machine tools — mechanical presses — safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 692:2009-04", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1910.217 (Mechanical Power Presses)", Relation: "partial", Confidence: "high", Notes: "OSHA is the primary US requirement for mechanical presses."},
|
|
{Region: "US-ANSI", Identifier: "ANSI B11.1-2009 (R2020) (Mechanical Power Presses)", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 17120-2012", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-693", BatchID: "1b",
|
|
Notes: "Machine tools — hydraulic presses — safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 693:2019-08", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B11.2-2013 (R2020) (Hydraulic Power Presses)", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 28241-2012", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-12622", BatchID: "1b",
|
|
Notes: "Machine tools — hydraulic press brakes — safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 12622:2014-04", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B11.3-2012 (R2017) (Power Press Brakes)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "ISO-10218-1", BatchID: "1b",
|
|
Notes: "Industrial robots — safety, robot manipulator. Updated 2025 edition exists.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN ISO 10218-1:2012-01", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/RIA R15.06-2012 (Part 1)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "CN-GB", Identifier: "GB 11291.1-2011", Relation: "equivalent", Confidence: "high"},
|
|
{Region: "JP-JIS", Identifier: "JIS B 8433-1:2015", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "ISO-10218-2", BatchID: "1b",
|
|
Notes: "Industrial robots — safety, integration. 2025 edition expands collaborative section.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN ISO 10218-2:2012-06", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/RIA R15.06-2012 (Part 2)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "CN-GB", Identifier: "GB 11291.2-2013", Relation: "equivalent", Confidence: "high"},
|
|
{Region: "JP-JIS", Identifier: "JIS B 8433-2:2015", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "ISO-TS-15066", BatchID: "1b",
|
|
Notes: "Collaborative robots — safety requirements (Technical Specification).",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN ISO/TS 15066:2017-04", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/RIA TR R15.606-2016", Relation: "identical", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-619", BatchID: "1b",
|
|
Notes: "Continuous handling equipment — packs and individual loads.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 619:2022-08", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B20.1-2021 (Conveyor Safety)", Relation: "partial", Confidence: "high"},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1926.555 (Conveyors)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-620", BatchID: "1b",
|
|
Notes: "Continuous handling equipment — belt conveyors for bulk materials.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 620:2022-08", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI/CEMA B20.1-2021", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB/T 10595-2017", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-349", BatchID: "1b",
|
|
Notes: "Minimum gaps to avoid crushing parts of the human body.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN ISO 13854:2020-04 (replaces EN 349)", Relation: "superseded_by", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "ISO 13854:2017", Relation: "supersedes", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B11.19-2019 §C.1 (Minimum clearance distances)", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 12265.3-1997 (now GB/T 23820-2009)", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-953", BatchID: "1b",
|
|
Notes: "Guards — withdrawn, replaced by EN ISO 14120.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 953:2009-08 (withdrawn 2017)", Relation: "superseded_by", Confidence: "verified"},
|
|
{Region: "INTL-ISO", Identifier: "ISO 14120:2015", Relation: "supersedes", Confidence: "verified"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "ISO-11161", BatchID: "1b",
|
|
Notes: "Safety of machinery — integrated manufacturing systems, basic requirements.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN ISO 11161:2010-05", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B11.20-2017 (Manufacturing Systems)", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB/T 19891-2005", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-1010-1", BatchID: "1b",
|
|
Notes: "Printing and paper-converting machines — common requirements.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 1010-1:2011-03", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B65.1-2011 (Printing Press Systems)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-12417", BatchID: "1b",
|
|
Notes: "Machine tools — machining centres safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 12417:2009-09", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B11.22-2002 (R2020) (Numerically Controlled Turning Machines)", Relation: "partial", Confidence: "medium"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "IEC-61800-5-2", BatchID: "1b",
|
|
Notes: "Adjustable speed electrical power drive systems — functional safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 61800-5-2:2018-08 (VDE 0160-105-2)", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-UL", Identifier: "UL 61800-5-1:2020", Relation: "partial", Confidence: "medium", Notes: "UL covers Part 5-1 (general safety); 5-2 functional safety often referenced directly."},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-201", BatchID: "1b",
|
|
Notes: "Plastics and rubber machines — injection moulding machines safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 201:2010-03", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B151.1-2017 (Injection Moulding Machines)", Relation: "partial", Confidence: "high"},
|
|
{Region: "CN-GB", Identifier: "GB 22530-2008", Relation: "equivalent", Confidence: "high"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-289", BatchID: "1b",
|
|
Notes: "Plastics and rubber machines — compression and transfer moulding machines safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 289:2014-09", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B151.27 (Compression Moulding)", Relation: "partial", Confidence: "medium"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-422", BatchID: "1b",
|
|
Notes: "Plastics and rubber machines — blow-moulding machines safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 422:2009-11", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B151.15 (Blow Moulding)", Relation: "partial", Confidence: "medium"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-1114-1", BatchID: "1b",
|
|
Notes: "Plastics and rubber machines — extruders and extrusion lines safety.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 1114-1:2011-09", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI B151.21 (Extrusion Blow Moulding)", Relation: "partial", Confidence: "medium"},
|
|
},
|
|
},
|
|
{
|
|
NormID: "EN-848-1", BatchID: "1b",
|
|
Notes: "Safety of woodworking machines — single-spindle vertical moulding machines.",
|
|
Mappings: []NormMapping{
|
|
{Region: "EU-DIN", Identifier: "DIN EN 848-1:2017-11", Relation: "identical", Confidence: "verified"},
|
|
{Region: "US-ANSI", Identifier: "ANSI O1.1-2019 (Woodworking Machinery)", Relation: "partial", Confidence: "high"},
|
|
{Region: "US-OSHA", Identifier: "29 CFR 1910.213 (Woodworking machinery)", Relation: "partial", Confidence: "high"},
|
|
},
|
|
},
|
|
}
|
|
}
|