Add dual-mode risk engine: legacy S×E×P (avoidance=0) and ISO mode S×F×P×A (avoidance>=1) with new thresholds (low/medium/high/very_high/not_acceptable). - 150+ hazard library entries across 28 categories incl. physical hazards (mechanical, electrical, thermal, pneumatic/hydraulic, noise/vibration, ergonomic, material/environmental) - 160-entry protective measures library with 3-step hierarchy validation (design → protective → information) - 25 lifecycle phases, 20 affected person roles, 50 evidence types - 10 verification methods (expanded from 7) - New API endpoints: lifecycle-phases, roles, evidence-types, protective-measures-library, validate-mitigation-hierarchy - DB migrations 018+019 for extended schema - Frontend: 4-slider risk assessment, hierarchy warnings, measures library modal - MkDocs wiki updated with ISO mode docs and legal notice (no norm text) All content uses original wording — norms referenced as methodology only. Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
3149 lines
197 KiB
Go
3149 lines
197 KiB
Go
package iace
|
||
|
||
import (
|
||
"encoding/json"
|
||
"fmt"
|
||
"time"
|
||
|
||
"github.com/google/uuid"
|
||
)
|
||
|
||
// hazardUUID generates a deterministic UUID for a hazard library entry
|
||
// based on category and a 1-based index within that category.
|
||
func hazardUUID(category string, index int) uuid.UUID {
|
||
name := fmt.Sprintf("iace.hazard.%s.%d", category, index)
|
||
return uuid.NewSHA1(uuid.NameSpaceDNS, []byte(name))
|
||
}
|
||
|
||
// mustMarshalJSON marshals the given value to json.RawMessage, panicking on error.
|
||
// This is safe to use for static data known at compile time.
|
||
func mustMarshalJSON(v interface{}) json.RawMessage {
|
||
data, err := json.Marshal(v)
|
||
if err != nil {
|
||
panic(fmt.Sprintf("hazard_library: failed to marshal JSON: %v", err))
|
||
}
|
||
return data
|
||
}
|
||
|
||
// GetBuiltinHazardLibrary returns the complete built-in hazard library with 40+
|
||
// template entries for SW/FW/KI hazards in industrial machines. These entries are
|
||
// intended to be seeded into the iace_hazard_library table during initial setup.
|
||
//
|
||
// All entries have IsBuiltin=true and TenantID=nil (system-level templates).
|
||
// UUIDs are deterministic, generated via uuid.NewSHA1 based on category and index.
|
||
func GetBuiltinHazardLibrary() []HazardLibraryEntry {
|
||
now := time.Now()
|
||
|
||
entries := []HazardLibraryEntry{
|
||
// ====================================================================
|
||
// Category: false_classification (4 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("false_classification", 1),
|
||
Category: "false_classification",
|
||
Name: "Falsche Bauteil-Klassifikation durch KI",
|
||
Description: "Das KI-Modell klassifiziert ein Bauteil fehlerhaft, was zu falscher Weiterverarbeitung oder Montage fuehren kann.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"ai_model", "sensor"},
|
||
RegulationReferences: []string{"EU AI Act Art. 9", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Redundante Pruefung", "Konfidenz-Schwellwert"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("false_classification", 2),
|
||
Category: "false_classification",
|
||
Name: "Falsche Qualitaetsentscheidung (IO/NIO)",
|
||
Description: "Fehlerhafte IO/NIO-Entscheidung durch das KI-System fuehrt dazu, dass defekte Teile als gut bewertet oder gute Teile verworfen werden.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"ai_model", "software"},
|
||
RegulationReferences: []string{"EU AI Act Art. 9", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Human-in-the-Loop", "Stichproben-Gegenpruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("false_classification", 3),
|
||
Category: "false_classification",
|
||
Name: "Fehlklassifikation bei Grenzwertfaellen",
|
||
Description: "Bauteile nahe an Toleranzgrenzen werden systematisch falsch klassifiziert, da das Modell in Grenzwertbereichen unsicher agiert.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
ApplicableComponentTypes: []string{"ai_model"},
|
||
RegulationReferences: []string{"EU AI Act Art. 9", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Erweitertes Training", "Grauzone-Eskalation"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("false_classification", 4),
|
||
Category: "false_classification",
|
||
Name: "Verwechslung von Bauteiltypen",
|
||
Description: "Unterschiedliche Bauteiltypen werden vom KI-Modell verwechselt, was zu falscher Montage oder Verarbeitung fuehrt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"ai_model", "sensor"},
|
||
RegulationReferences: []string{"EU AI Act Art. 9", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Barcode-Gegenpruefung", "Doppelte Sensorik"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: timing_error (3 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("timing_error", 1),
|
||
Category: "timing_error",
|
||
Name: "Verzoegerte KI-Reaktion in Echtzeitsystem",
|
||
Description: "Die KI-Inferenz dauert laenger als die zulaessige Echtzeitfrist, was zu verspaeteten Sicherheitsreaktionen fuehrt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "ai_model"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Watchdog-Timer", "Fallback-Steuerung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("timing_error", 2),
|
||
Category: "timing_error",
|
||
Name: "Echtzeit-Verletzung Safety-Loop",
|
||
Description: "Der sicherheitsgerichtete Regelkreis kann die geforderten Zykluszeiten nicht einhalten, wodurch Sicherheitsfunktionen versagen koennen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"ISO 13849", "IEC 61508", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Deterministische Ausfuehrung", "WCET-Analyse"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("timing_error", 3),
|
||
Category: "timing_error",
|
||
Name: "Timing-Jitter bei Netzwerkkommunikation",
|
||
Description: "Schwankende Netzwerklatenzen fuehren zu unvorhersehbaren Verzoegerungen in der Datenuebertragung sicherheitsrelevanter Signale.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"network", "software"},
|
||
RegulationReferences: []string{"IEC 62443", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"TSN-Netzwerk", "Pufferung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: data_poisoning (2 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("data_poisoning", 1),
|
||
Category: "data_poisoning",
|
||
Name: "Manipulierte Trainingsdaten",
|
||
Description: "Trainingsdaten werden absichtlich oder unbeabsichtigt manipuliert, wodurch das Modell systematisch fehlerhafte Entscheidungen trifft.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"ai_model"},
|
||
RegulationReferences: []string{"EU AI Act Art. 10", "CRA"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Daten-Validierung", "Anomalie-Erkennung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("data_poisoning", 2),
|
||
Category: "data_poisoning",
|
||
Name: "Adversarial Input Angriff",
|
||
Description: "Gezielte Manipulation von Eingabedaten (z.B. Bilder, Sensorsignale), um das KI-Modell zu taeuschen und Fehlentscheidungen auszuloesen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"ai_model", "sensor"},
|
||
RegulationReferences: []string{"EU AI Act Art. 15", "CRA", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Input-Validation", "Adversarial Training"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: model_drift (3 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("model_drift", 1),
|
||
Category: "model_drift",
|
||
Name: "Performance-Degradation durch Concept Drift",
|
||
Description: "Die statistische Verteilung der Eingabedaten aendert sich ueber die Zeit, wodurch die Modellgenauigkeit schleichend abnimmt.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
ApplicableComponentTypes: []string{"ai_model"},
|
||
RegulationReferences: []string{"EU AI Act Art. 9", "EU AI Act Art. 72"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Monitoring-Dashboard", "Automatisches Retraining"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("model_drift", 2),
|
||
Category: "model_drift",
|
||
Name: "Data Drift durch veraenderte Umgebung",
|
||
Description: "Aenderungen in der physischen Umgebung (Beleuchtung, Temperatur, Material) fuehren zu veraenderten Sensordaten und Modellfehlern.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
ApplicableComponentTypes: []string{"ai_model", "sensor"},
|
||
RegulationReferences: []string{"EU AI Act Art. 9", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Statistische Ueberwachung", "Sensor-Kalibrierung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("model_drift", 3),
|
||
Category: "model_drift",
|
||
Name: "Schleichende Modell-Verschlechterung",
|
||
Description: "Ohne aktives Monitoring verschlechtert sich die Modellqualitaet ueber Wochen oder Monate unbemerkt.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"ai_model"},
|
||
RegulationReferences: []string{"EU AI Act Art. 9", "EU AI Act Art. 72"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Regelmaessige Evaluierung", "A/B-Testing"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: sensor_spoofing (3 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("sensor_spoofing", 1),
|
||
Category: "sensor_spoofing",
|
||
Name: "Kamera-Manipulation / Abdeckung",
|
||
Description: "Kamerasensoren werden absichtlich oder unbeabsichtigt abgedeckt oder manipuliert, sodass das System auf Basis falscher Bilddaten agiert.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"sensor"},
|
||
RegulationReferences: []string{"IEC 62443", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Plausibilitaetspruefung", "Mehrfach-Sensorik"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("sensor_spoofing", 2),
|
||
Category: "sensor_spoofing",
|
||
Name: "Sensor-Signal-Injection",
|
||
Description: "Einspeisung gefaelschter Signale in die Sensorleitungen oder Schnittstellen, um das System gezielt zu manipulieren.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 1,
|
||
ApplicableComponentTypes: []string{"sensor", "network"},
|
||
RegulationReferences: []string{"IEC 62443", "CRA"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Signalverschluesselung", "Anomalie-Erkennung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("sensor_spoofing", 3),
|
||
Category: "sensor_spoofing",
|
||
Name: "Umgebungsbasierte Sensor-Taeuschung",
|
||
Description: "Natuerliche oder kuenstliche Umgebungsveraenderungen (Licht, Staub, Vibration) fuehren zu fehlerhaften Sensorwerten.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"sensor"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Sensor-Fusion", "Redundanz"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: communication_failure (3 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("communication_failure", 1),
|
||
Category: "communication_failure",
|
||
Name: "Feldbus-Ausfall",
|
||
Description: "Ausfall des industriellen Feldbusses (z.B. PROFINET, EtherCAT) fuehrt zum Verlust der Kommunikation zwischen Steuerung und Aktorik.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"network", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Redundanter Bus", "Safe-State-Transition"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("communication_failure", 2),
|
||
Category: "communication_failure",
|
||
Name: "Cloud-Verbindungsverlust",
|
||
Description: "Die Verbindung zur Cloud-Infrastruktur bricht ab, wodurch cloud-abhaengige Funktionen (z.B. Modell-Updates, Monitoring) nicht verfuegbar sind.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
ApplicableComponentTypes: []string{"network", "software"},
|
||
RegulationReferences: []string{"CRA", "EU AI Act Art. 15"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Offline-Faehigkeit", "Edge-Computing"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("communication_failure", 3),
|
||
Category: "communication_failure",
|
||
Name: "Netzwerk-Latenz-Spitzen",
|
||
Description: "Unkontrollierte Latenzspitzen im Netzwerk fuehren zu Timeouts und verspaeteter Datenlieferung an sicherheitsrelevante Systeme.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"network"},
|
||
RegulationReferences: []string{"IEC 62443", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"QoS-Konfiguration", "Timeout-Handling"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: unauthorized_access (4 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("unauthorized_access", 1),
|
||
Category: "unauthorized_access",
|
||
Name: "Unautorisierter Remote-Zugriff",
|
||
Description: "Ein Angreifer erlangt ueber das Netzwerk Zugriff auf die Maschinensteuerung und kann sicherheitsrelevante Parameter aendern.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"network", "software"},
|
||
RegulationReferences: []string{"IEC 62443", "CRA", "EU AI Act Art. 15"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"VPN", "MFA", "Netzwerksegmentierung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("unauthorized_access", 2),
|
||
Category: "unauthorized_access",
|
||
Name: "Konfigurations-Manipulation",
|
||
Description: "Sicherheitsrelevante Konfigurationsparameter werden unautorisiert geaendert, z.B. Grenzwerte, Schwellwerte oder Betriebsmodi.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62443", "CRA", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Zugriffskontrolle", "Audit-Log"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("unauthorized_access", 3),
|
||
Category: "unauthorized_access",
|
||
Name: "Privilege Escalation",
|
||
Description: "Ein Benutzer oder Prozess erlangt hoehere Berechtigungen als vorgesehen und kann sicherheitskritische Aktionen ausfuehren.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 1,
|
||
ApplicableComponentTypes: []string{"software"},
|
||
RegulationReferences: []string{"IEC 62443", "CRA"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"RBAC", "Least Privilege"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("unauthorized_access", 4),
|
||
Category: "unauthorized_access",
|
||
Name: "Supply-Chain-Angriff auf Komponente",
|
||
Description: "Eine kompromittierte Softwarekomponente oder Firmware wird ueber die Lieferkette eingeschleust und enthaelt Schadcode oder Backdoors.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 1,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"CRA", "IEC 62443", "EU AI Act Art. 15"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"SBOM", "Signaturpruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: firmware_corruption (3 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("firmware_corruption", 1),
|
||
Category: "firmware_corruption",
|
||
Name: "Update-Abbruch mit inkonsistentem Zustand",
|
||
Description: "Ein Firmware-Update wird unterbrochen (z.B. Stromausfall), wodurch das System in einem inkonsistenten und potenziell unsicheren Zustand verbleibt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"firmware"},
|
||
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"A/B-Partitioning", "Rollback"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("firmware_corruption", 2),
|
||
Category: "firmware_corruption",
|
||
Name: "Rollback-Fehler auf alte Version",
|
||
Description: "Ein Rollback auf eine aeltere Firmware-Version schlaegt fehl oder fuehrt zu Inkompatibilitaeten mit der aktuellen Hardware-/Softwarekonfiguration.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"firmware"},
|
||
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Versionsmanagement", "Kompatibilitaetspruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("firmware_corruption", 3),
|
||
Category: "firmware_corruption",
|
||
Name: "Boot-Chain-Angriff",
|
||
Description: "Die Bootsequenz wird manipuliert, um unsignierte oder kompromittierte Firmware auszufuehren, was die gesamte Sicherheitsarchitektur untergaebt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 1,
|
||
ApplicableComponentTypes: []string{"firmware"},
|
||
RegulationReferences: []string{"CRA", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Secure Boot", "TPM"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: safety_boundary_violation (4 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("safety_boundary_violation", 1),
|
||
Category: "safety_boundary_violation",
|
||
Name: "Kraft-/Drehmoment-Ueberschreitung",
|
||
Description: "Aktorische Systeme ueberschreiten die zulaessigen Kraft- oder Drehmomentwerte, was zu Verletzungen oder Maschinenschaeden fuehren kann.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Hardware-Limiter", "SIL-Ueberwachung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_boundary_violation", 2),
|
||
Category: "safety_boundary_violation",
|
||
Name: "Geschwindigkeitsueberschreitung Roboter",
|
||
Description: "Ein Industrieroboter ueberschreitet die zulaessige Geschwindigkeit, insbesondere bei Mensch-Roboter-Kollaboration.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "ISO 10218"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Safe Speed Monitoring", "Lichtgitter"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_boundary_violation", 3),
|
||
Category: "safety_boundary_violation",
|
||
Name: "Versagen des Safe-State",
|
||
Description: "Das System kann im Fehlerfall keinen sicheren Zustand einnehmen, da die Sicherheitssteuerung selbst versagt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 1,
|
||
ApplicableComponentTypes: []string{"controller", "software", "firmware"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Redundante Sicherheitssteuerung", "Diverse Programmierung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_boundary_violation", 4),
|
||
Category: "safety_boundary_violation",
|
||
Name: "Arbeitsraum-Verletzung",
|
||
Description: "Ein Roboter oder Aktor verlaesst seinen definierten Arbeitsraum und dringt in den Schutzbereich von Personen ein.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller", "sensor"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "ISO 10218"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Sichere Achsueberwachung", "Schutzzaun-Sensorik"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: mode_confusion (3 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("mode_confusion", 1),
|
||
Category: "mode_confusion",
|
||
Name: "Falsche Betriebsart aktiv",
|
||
Description: "Das System befindet sich in einer unbeabsichtigten Betriebsart (z.B. Automatik statt Einrichtbetrieb), was zu unerwarteten Maschinenbewegungen fuehrt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"hmi", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Betriebsart-Anzeige", "Schluesselschalter"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mode_confusion", 2),
|
||
Category: "mode_confusion",
|
||
Name: "Wartung/Normal-Verwechslung",
|
||
Description: "Das System wird im Normalbetrieb gewartet oder der Wartungsmodus wird nicht korrekt verlassen, was zu gefaehrlichen Situationen fuehrt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"hmi", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Zugangskontrolle", "Sicherheitsverriegelung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mode_confusion", 3),
|
||
Category: "mode_confusion",
|
||
Name: "Automatik-Eingriff waehrend Handbetrieb",
|
||
Description: "Das System wechselt waehrend des Handbetriebs unerwartet in den Automatikbetrieb, wodurch eine Person im Gefahrenbereich verletzt werden kann.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Exklusive Betriebsarten", "Zustimmtaster"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: unintended_bias (2 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("unintended_bias", 1),
|
||
Category: "unintended_bias",
|
||
Name: "Diskriminierende KI-Entscheidung",
|
||
Description: "Das KI-Modell trifft systematisch diskriminierende Entscheidungen, z.B. bei der Qualitaetsbewertung bestimmter Produktchargen oder Lieferanten.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"ai_model"},
|
||
RegulationReferences: []string{"EU AI Act Art. 10", "EU AI Act Art. 71"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Bias-Testing", "Fairness-Metriken"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("unintended_bias", 2),
|
||
Category: "unintended_bias",
|
||
Name: "Verzerrte Trainingsdaten",
|
||
Description: "Die Trainingsdaten sind nicht repraesentativ und enthalten systematische Verzerrungen, die zu unfairen oder fehlerhaften Modellergebnissen fuehren.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"ai_model"},
|
||
RegulationReferences: []string{"EU AI Act Art. 10", "EU AI Act Art. 71"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Datensatz-Audit", "Ausgewogenes Sampling"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: update_failure (3 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("update_failure", 1),
|
||
Category: "update_failure",
|
||
Name: "Unvollstaendiges OTA-Update",
|
||
Description: "Ein Over-the-Air-Update wird nur teilweise uebertragen oder angewendet, wodurch das System in einem inkonsistenten Zustand verbleibt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"firmware", "software"},
|
||
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Atomare Updates", "Integritaetspruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("update_failure", 2),
|
||
Category: "update_failure",
|
||
Name: "Versionskonflikt nach Update",
|
||
Description: "Nach einem Update sind Software- und Firmware-Versionen inkompatibel, was zu Fehlfunktionen oder Ausfaellen fuehrt.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Kompatibilitaetsmatrix", "Staging-Tests"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("update_failure", 3),
|
||
Category: "update_failure",
|
||
Name: "Unkontrollierter Auto-Update",
|
||
Description: "Ein automatisches Update wird ohne Genehmigung oder ausserhalb eines Wartungsfensters eingespielt und stoert den laufenden Betrieb.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software"},
|
||
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Update-Genehmigung", "Wartungsfenster"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
}
|
||
|
||
// ====================================================================
|
||
// Neue Kategorien (extended library ~100 neue Eintraege)
|
||
// ====================================================================
|
||
|
||
extended := []HazardLibraryEntry{
|
||
// ====================================================================
|
||
// Category: software_fault (10 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("software_fault", 1),
|
||
Category: "software_fault",
|
||
Name: "Race Condition in Sicherheitsfunktion",
|
||
Description: "Zwei Tasks greifen ohne Synchronisation auf gemeinsame Ressourcen zu, was zu unvorhersehbarem Verhalten in sicherheitsrelevanten Funktionen fuehren kann.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"EU 2023/1230 Anhang I §1.2", "IEC 62304", "IEC 61508"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Mutex/Semaphor", "RTOS-Task-Prioritaeten", "WCET-Analyse"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 2),
|
||
Category: "software_fault",
|
||
Name: "Stack Overflow in Echtzeit-Task",
|
||
Description: "Ein rekursiver Aufruf oder grosse lokale Variablen fuehren zum Stack-Ueberlauf, was Safety-Tasks zum Absturz bringt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "IEC 61508"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Stack-Groessen-Analyse", "Stack-Guard", "Statische Code-Analyse"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 3),
|
||
Category: "software_fault",
|
||
Name: "Integer Overflow in Sicherheitsberechnung",
|
||
Description: "Arithmetischer Ueberlauf bei der Berechnung sicherheitskritischer Grenzwerte fuehrt zu falschen Ergebnissen und unkontrolliertem Verhalten.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "MISRA-C", "IEC 61508"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Datentyp-Pruefung", "Overflow-Detection", "MISRA-C-Analyse"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 4),
|
||
Category: "software_fault",
|
||
Name: "Deadlock zwischen Safety-Tasks",
|
||
Description: "Gegenseitige Sperrung von Tasks durch zyklische Ressourcenabhaengigkeiten verhindert die Ausfuehrung sicherheitsrelevanter Funktionen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "IEC 61508"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Ressourcen-Hierarchie", "Watchdog", "Deadlock-Analyse"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 5),
|
||
Category: "software_fault",
|
||
Name: "Memory Leak im Langzeitbetrieb",
|
||
Description: "Nicht freigegebener Heap-Speicher akkumuliert sich ueber Zeit, bis das System abstuerzt und Sicherheitsfunktionen nicht mehr verfuegbar sind.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
ApplicableComponentTypes: []string{"software"},
|
||
RegulationReferences: []string{"IEC 62304", "IEC 61508"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Memory-Profiling", "Valgrind", "Statisches Speichermanagement"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 6),
|
||
Category: "software_fault",
|
||
Name: "Null-Pointer-Dereferenz in Safety-Code",
|
||
Description: "Zugriff auf einen Null-Zeiger fuehrt zu einem undefinierten Systemzustand oder Absturz des sicherheitsrelevanten Software-Moduls.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "MISRA-C"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Null-Check vor Zugriff", "Statische Analyse", "Defensiv-Programmierung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 7),
|
||
Category: "software_fault",
|
||
Name: "Unbehandelte Ausnahme in Safety-Code",
|
||
Description: "Eine nicht abgefangene Ausnahme bricht die Ausfuehrung des sicherheitsrelevanten Codes ab und hinterlaesst das System in einem undefinierten Zustand.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software"},
|
||
RegulationReferences: []string{"IEC 62304", "IEC 61508"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Globaler Exception-Handler", "Exception-Safety-Analyse", "Fail-Safe-Rueckfall"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 8),
|
||
Category: "software_fault",
|
||
Name: "Korrupte Konfigurationsdaten",
|
||
Description: "Beschaedigte oder unvollstaendige Konfigurationsdaten werden ohne Validierung geladen und fuehren zu falschem Systemverhalten.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Konfig-Validierung", "CRC-Pruefung", "Fallback-Konfiguration"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 9),
|
||
Category: "software_fault",
|
||
Name: "Division durch Null in Regelkreis",
|
||
Description: "Ein Divisor im sicherheitsrelevanten Regelkreis erreicht den Wert Null, was zu einem Laufzeitfehler oder undefiniertem Ergebnis fuehrt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "IEC 61508", "MISRA-C"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Vorbedingungspruefung", "Statische Analyse", "Defensiv-Programmierung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("software_fault", 10),
|
||
Category: "software_fault",
|
||
Name: "Falscher Safety-Parameter durch Software-Bug",
|
||
Description: "Ein Software-Fehler setzt einen sicherheitsrelevanten Parameter auf einen falschen Wert, ohne dass eine Plausibilitaetspruefung dies erkennt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "IEC 61508", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Parametervalidierung", "Redundante Speicherung", "Diversitaere Pruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: hmi_error (8 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("hmi_error", 1),
|
||
Category: "hmi_error",
|
||
Name: "Falsche Einheitendarstellung",
|
||
Description: "Das HMI zeigt Werte in einer falschen Masseinheit an (z.B. mm statt inch), was zu Fehlbedienung und Maschinenfehlern fuehren kann.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"hmi", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang III", "EN ISO 9241"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Einheiten-Label im UI", "Lokalisierungstests", "Einheiten-Konvertierungspruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("hmi_error", 2),
|
||
Category: "hmi_error",
|
||
Name: "Fehlender oder stummer Sicherheitsalarm",
|
||
Description: "Ein kritisches Sicherheitsereignis wird dem Bediener nicht oder nicht rechtzeitig angezeigt, weil die Alarmfunktion deaktiviert oder fehlerhaft ist.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"hmi", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "EN ISO 9241"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Alarmtest im Rahmen der Inbetriebnahme", "Akustischer Backup-Alarm", "Alarmverwaltungssystem"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("hmi_error", 3),
|
||
Category: "hmi_error",
|
||
Name: "Sprachfehler in Bedienoberflaeche",
|
||
Description: "Fehlerhafte oder mehrdeutige Bezeichnungen in der Benutzersprache fuehren zu Fehlbedienung sicherheitsrelevanter Funktionen.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"hmi"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang III"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Usability-Test", "Lokalisierungs-Review", "Mehrsprachige Dokumentation"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("hmi_error", 4),
|
||
Category: "hmi_error",
|
||
Name: "Fehlende Eingabevalidierung im HMI",
|
||
Description: "Das HMI akzeptiert ausserhalb des gueltigen Bereichs liegende Eingaben ohne Warnung und leitet sie an die Steuerung weiter.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"hmi", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62304"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Grenzwertpruefung", "Eingabemaske mit Bereichen", "Warnung bei Grenzwertnaehe"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("hmi_error", 5),
|
||
Category: "hmi_error",
|
||
Name: "Defekter Statusindikator",
|
||
Description: "Ein LED, Anzeigeelement oder Softwaresymbol zeigt einen falschen Systemstatus an und verleitet den Bediener zu falschen Annahmen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"hmi"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang III"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Regelmaessige HMI-Tests", "Selbsttest beim Einschalten", "Redundante Statusanzeige"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("hmi_error", 6),
|
||
Category: "hmi_error",
|
||
Name: "Quittierung ohne Ursachenbehebung",
|
||
Description: "Der Bediener kann einen Sicherheitsalarm quittieren, ohne die zugrundeliegende Ursache behoben zu haben, was das Risiko wiederkehrender Ereignisse erhoet.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"hmi", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Ursachen-Checkliste vor Quittierung", "Pflicht-Ursachen-Eingabe", "Audit-Log der Quittierungen"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("hmi_error", 7),
|
||
Category: "hmi_error",
|
||
Name: "Veraltete Anzeige durch Caching-Fehler",
|
||
Description: "Die HMI-Anzeige wird nicht aktualisiert und zeigt veraltete Sensorwerte oder Zustaende an, was zu Fehlentscheidungen fuehrt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"hmi", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang III"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Timestamp-Anzeige", "Refresh-Watchdog", "Verbindungsstatus-Indikator"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("hmi_error", 8),
|
||
Category: "hmi_error",
|
||
Name: "Fehlende Betriebsart-Kennzeichnung",
|
||
Description: "Die aktive Betriebsart (Automatik, Einrichten, Wartung) ist im HMI nicht eindeutig sichtbar, was zu unerwarteten Maschinenbewegungen fuehren kann.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"hmi", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Dauerhafte Betriebsart-Anzeige", "Farbliche Kennzeichnung", "Bestaetigung bei Modewechsel"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: mechanical_hazard (6 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 1),
|
||
Category: "mechanical_hazard",
|
||
Name: "Unerwarteter Anlauf nach Spannungsausfall",
|
||
Description: "Nach Wiederkehr der Versorgungsspannung laeuft die Maschine unerwartet an, ohne dass eine Startfreigabe durch den Bediener erfolgt ist.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"controller", "firmware"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.2.6", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Anlaufschutz", "Anti-Restart-Funktion", "Sicherheitsrelais"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 2),
|
||
Category: "mechanical_hazard",
|
||
Name: "Restenergie nach Abschalten",
|
||
Description: "Gespeicherte kinetische oder potentielle Energie (z.B. Schwungmasse, abgesenktes Werkzeug) wird nach dem Abschalten nicht sicher abgebaut.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"actuator", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Energieabbau-Prozedur", "Mechanische Haltevorrichtung", "LOTO-Freischaltung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 3),
|
||
Category: "mechanical_hazard",
|
||
Name: "Unerwartete Maschinenbewegung",
|
||
Description: "Die Maschine fuehrt eine unkontrollierte Bewegung durch (z.B. Antrieb faehrt ohne Kommando los), was Personen im Gefahrenbereich verletzt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"actuator", "controller", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Safe Torque Off (STO)", "Geschwindigkeitsueberwachung", "Schutzzaun-Sensorik"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 4),
|
||
Category: "mechanical_hazard",
|
||
Name: "Teileauswurf durch Fehlfunktion",
|
||
Description: "Werkzeuge, Werkstuecke oder Maschinenteile werden bei einer Fehlfunktion unkontrolliert aus der Maschine geschleudert.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"actuator", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.2"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Trennende Schutzeinrichtung", "Sicherheitsglas", "Spannkraft-Ueberwachung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 5),
|
||
Category: "mechanical_hazard",
|
||
Name: "Quetschstelle durch fehlende Schutzeinrichtung",
|
||
Description: "Zwischen beweglichen und festen Maschinenteilen entstehen Quetschstellen, die bei fehlendem Schutz zu schweren Verletzungen fuehren koennen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.7", "ISO 13857"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schutzverkleidung", "Sicherheitsabstaende nach ISO 13857", "Lichtvorhang"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 6),
|
||
Category: "mechanical_hazard",
|
||
Name: "Instabile Struktur unter Last",
|
||
Description: "Die Maschinenstruktur oder ein Anbauteil versagt unter statischer oder dynamischer Belastung und gefaehrdet Personen in der Naehe.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 1,
|
||
ApplicableComponentTypes: []string{"other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.3.1"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Festigkeitsberechnung", "Ueberlastsicherung", "Regelmaessige Inspektion"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: electrical_hazard (6 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 1),
|
||
Category: "electrical_hazard",
|
||
Name: "Elektrischer Schlag an Bedienpanel",
|
||
Description: "Bediener kommen mit spannungsfuehrenden Teilen in Beruehrung, z.B. durch defekte Gehaeuseerdung oder fehlerhafte Isolierung.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"hmi", "controller"},
|
||
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schutzkleinspannung (SELV)", "Schutzerdung", "Isolationsmonitoring"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 2),
|
||
Category: "electrical_hazard",
|
||
Name: "Lichtbogen durch Schaltfehler",
|
||
Description: "Ein Schaltfehler erzeugt einen Lichtbogen, der Bediener verletzen, Geraete beschaedigen oder einen Brand ausloesen kann.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 1,
|
||
ApplicableComponentTypes: []string{"controller"},
|
||
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Lichtbogenschutz-Schalter", "Kurzschlussschutz", "Geeignete Schaltgeraete"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 3),
|
||
Category: "electrical_hazard",
|
||
Name: "Kurzschluss durch Isolationsfehler",
|
||
Description: "Beschaedigte Kabelisolierungen fuehren zu einem Kurzschluss, der Feuer ausloesen oder Sicherheitsfunktionen ausser Betrieb setzen kann.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"network", "controller"},
|
||
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Isolationsueberwachung", "Kabelschutz", "Regelmaessige Sichtpruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 4),
|
||
Category: "electrical_hazard",
|
||
Name: "Erdschluss in Steuerkreis",
|
||
Description: "Ein Erdschluss im Steuerkreis kann unbeabsichtigte Schaltzustaende ausloesen und Sicherheitsfunktionen beeinflussen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller", "network"},
|
||
RegulationReferences: []string{"IEC 60204-1", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Erdschluss-Monitoring", "IT-Netz fuer Steuerkreise", "Regelmaessige Pruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 5),
|
||
Category: "electrical_hazard",
|
||
Name: "Gespeicherte Energie in Kondensatoren",
|
||
Description: "Nach dem Abschalten verbleiben hohe Spannungen in Kondensatoren (z.B. Frequenzumrichter, USV), was bei Wartungsarbeiten gefaehrlich ist.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller"},
|
||
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Entladewartezeit", "Automatische Entladeschaltung", "Warnhinweise am Geraet"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 6),
|
||
Category: "electrical_hazard",
|
||
Name: "Elektromagnetische Kopplung auf Safety-Leitung",
|
||
Description: "Hochfrequente Stoerfelder koppeln auf ungeschirmte Safety-Leitungen und erzeugen Falschsignale, die Sicherheitsfunktionen fehl ausloesen.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"network", "sensor"},
|
||
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 62061"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Geschirmte Kabel", "Raeumliche Trennung", "EMV-Pruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: thermal_hazard (4 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("thermal_hazard", 1),
|
||
Category: "thermal_hazard",
|
||
Name: "Ueberhitzung der Steuereinheit",
|
||
Description: "Die Steuereinheit ueberschreitet die zulaessige Betriebstemperatur durch Lueftungsausfall oder hohe Umgebungstemperatur, was zu Fehlfunktionen fuehrt.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"controller", "firmware"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Temperaturueberwachung", "Redundante Lueftung", "Thermisches Abschalten"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("thermal_hazard", 2),
|
||
Category: "thermal_hazard",
|
||
Name: "Brandgefahr durch Leistungselektronik",
|
||
Description: "Defekte Leistungshalbleiter oder Kondensatoren in der Leistungselektronik erwaermen sich unkontrolliert und koennen einen Brand ausloesen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller"},
|
||
RegulationReferences: []string{"Niederspannungsrichtlinie 2014/35/EU", "IEC 60204-1"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Thermosicherungen", "Temperatursensoren", "Brandschutzmassnahmen"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("thermal_hazard", 3),
|
||
Category: "thermal_hazard",
|
||
Name: "Einfrieren bei Tieftemperatur",
|
||
Description: "Sehr tiefe Umgebungstemperaturen fuehren zum Einfrieren von Hydraulikleitungen oder Elektronik und damit zum Ausfall von Sicherheitsfunktionen.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"controller", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Heizung", "Mindestbetriebstemperatur definieren", "Temperatursensor"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("thermal_hazard", 4),
|
||
Category: "thermal_hazard",
|
||
Name: "Waermestress an Kabelisolierung",
|
||
Description: "Langfristige Einwirkung hoher Temperaturen auf Kabelisolierungen fuehrt zu Alterung und Isolationsversagen mit Kurzschlussrisiko.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"network", "controller"},
|
||
RegulationReferences: []string{"IEC 60204-1", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Hitzebestaendige Kabel (z.B. PTFE)", "Kabelverlegung mit Abstand zur Waermequelle", "Regelmaessige Inspektion"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: emc_hazard (5 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("emc_hazard", 1),
|
||
Category: "emc_hazard",
|
||
Name: "EMV-Stoerabstrahlung auf Safety-Bus",
|
||
Description: "Hohe elektromagnetische Stoerabstrahlung aus benachbarten Geraeten stoert den industriellen Safety-Bus (z.B. PROFIsafe) und erzeugt Kommunikationsfehler.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"network", "controller"},
|
||
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 62061", "IEC 61784-3"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"EMV-gerechte Verkabelung", "Schirmung", "EMC-Pruefung nach EN 55011"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("emc_hazard", 2),
|
||
Category: "emc_hazard",
|
||
Name: "Unbeabsichtigte elektromagnetische Abstrahlung",
|
||
Description: "Die Maschine selbst strahlt starke EM-Felder ab, die andere sicherheitsrelevante Einrichtungen in der Naehe stoeren.",
|
||
DefaultSeverity: 2,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"controller", "actuator"},
|
||
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"EMV-Filter", "Gehaeuseabschirmung", "CE-Zulassung Frequenzumrichter"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("emc_hazard", 3),
|
||
Category: "emc_hazard",
|
||
Name: "Frequenzumrichter-Stoerung auf Steuerleitung",
|
||
Description: "Der Frequenzumrichter erzeugt hochfrequente Stoerungen, die auf benachbarte Steuerleitungen koppeln und falsche Signale erzeugen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"actuator", "network"},
|
||
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 60204-1"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Motorfilter", "Kabeltrennabstand", "Separate Kabelkanaele"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("emc_hazard", 4),
|
||
Category: "emc_hazard",
|
||
Name: "ESD-Schaden an Elektronik",
|
||
Description: "Elektrostatische Entladung bei Wartung oder Austausch beschaedigt empfindliche Elektronikbauteile, was zu latenten Fehlfunktionen fuehrt.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"controller", "firmware"},
|
||
RegulationReferences: []string{"IEC 61000-4-2", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"ESD-Schulung", "ESD-Schutzausruestung", "ESD-gerechte Verpackung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("emc_hazard", 5),
|
||
Category: "emc_hazard",
|
||
Name: "HF-Stoerung des Sicherheitssensors",
|
||
Description: "Hochfrequenz-Stoerquellen (z.B. Schweissgeraete, Mobiltelefone) beeinflussen die Funktion von Sicherheitssensoren (Lichtvorhang, Scanner).",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"sensor"},
|
||
RegulationReferences: []string{"EMV-Richtlinie 2014/30/EU", "IEC 61496"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"EMV-zertifizierte Sicherheitssensoren", "HF-Quellen trennen", "Gegensprechanlagenverbot in Gefahrenzone"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: configuration_error (8 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("configuration_error", 1),
|
||
Category: "configuration_error",
|
||
Name: "Falscher Safety-Parameter bei Inbetriebnahme",
|
||
Description: "Beim Einrichten werden sicherheitsrelevante Parameter (z.B. Maximalgeschwindigkeit, Abschaltgrenzen) falsch konfiguriert und nicht verifiziert.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849", "IEC 62061"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Parameterpruefung nach Inbetriebnahme", "4-Augen-Prinzip", "Parameterprotokoll in technischer Akte"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("configuration_error", 2),
|
||
Category: "configuration_error",
|
||
Name: "Factory Reset loescht Sicherheitskonfiguration",
|
||
Description: "Ein Factory Reset setzt alle Parameter auf Werkseinstellungen zurueck, einschliesslich sicherheitsrelevanter Konfigurationen, ohne Warnung.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"firmware", "software"},
|
||
RegulationReferences: []string{"IEC 62304", "CRA", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Separate Safety-Partition", "Bestaetigung vor Reset", "Safety-Config vor Reset sichern"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("configuration_error", 3),
|
||
Category: "configuration_error",
|
||
Name: "Fehlerhafte Parameter-Migration bei Update",
|
||
Description: "Beim Software-Update werden vorhandene Konfigurationsparameter nicht korrekt in das neue Format migriert, was zu falschen Systemeinstellungen fuehrt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "CRA"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Migrations-Skript-Tests", "Konfig-Backup vor Update", "Post-Update-Verifikation"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("configuration_error", 4),
|
||
Category: "configuration_error",
|
||
Name: "Konflikthafte redundante Einstellungen",
|
||
Description: "Widersprüchliche Parameter in verschiedenen Konfigurationsdateien oder -ebenen fuehren zu unvorhersehbarem Systemverhalten.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62304", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Konfig-Validierung beim Start", "Einzelne Quelle fuer Safety-Params", "Konsistenzpruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("configuration_error", 5),
|
||
Category: "configuration_error",
|
||
Name: "Hard-coded Credentials in Konfiguration",
|
||
Description: "Passwörter oder Schluessel sind fest im Code oder in Konfigurationsdateien hinterlegt und koennen nicht geaendert werden.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"CRA", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Secrets-Management", "Kein Hard-Coding", "Credential-Scan im CI"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("configuration_error", 6),
|
||
Category: "configuration_error",
|
||
Name: "Debug-Modus in Produktionsumgebung aktiv",
|
||
Description: "Debug-Schnittstellen oder erhoehte Logging-Level sind in der Produktionsumgebung aktiv und ermoeglichen Angreifern Zugang zu sensiblen Systeminfos.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"CRA", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Build-Konfiguration pruefe Debug-Flag", "Produktions-Checkliste", "Debug-Port-Deaktivierung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("configuration_error", 7),
|
||
Category: "configuration_error",
|
||
Name: "Out-of-Bounds-Eingabe ohne Validierung",
|
||
Description: "Nutzereingaben oder Schnittstellendaten werden ohne Bereichspruefung in sicherheitsrelevante Parameter uebernommen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "hmi"},
|
||
RegulationReferences: []string{"IEC 62304", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Eingabevalidierung", "Bereichsgrenzen definieren", "Sanity-Check"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("configuration_error", 8),
|
||
Category: "configuration_error",
|
||
Name: "Konfigurationsdatei nicht schreibgeschuetzt",
|
||
Description: "Sicherheitsrelevante Konfigurationsdateien koennen von unautorisierten Nutzern oder Prozessen veraendert werden.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "firmware"},
|
||
RegulationReferences: []string{"IEC 62443", "CRA"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Dateisystem-Berechtigungen", "Code-Signing fuer Konfig", "Integritaetspruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: safety_function_failure (8 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("safety_function_failure", 1),
|
||
Category: "safety_function_failure",
|
||
Name: "Not-Halt trennt Energieversorgung nicht",
|
||
Description: "Der Not-Halt-Taster betaetigt die Sicherheitsschalter, die Energiezufuhr wird jedoch nicht vollstaendig unterbrochen, weil das Sicherheitsrelais versagt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.2.4", "IEC 60947-5-5", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Regelmaessiger Not-Halt-Test", "Redundantes Sicherheitsrelais", "Selbstueberwachender Sicherheitskreis"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_function_failure", 2),
|
||
Category: "safety_function_failure",
|
||
Name: "Schutztuer-Monitoring umgangen",
|
||
Description: "Das Schutztuer-Positionssignal wird durch einen Fehler oder Manipulation als 'geschlossen' gemeldet, obwohl die Tuer offen ist.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"sensor", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 14119", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Zwangsöffnender Positionsschalter", "Codierter Sicherheitssensor", "Anti-Tamper-Masssnahmen"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_function_failure", 3),
|
||
Category: "safety_function_failure",
|
||
Name: "Safe Speed Monitoring fehlt",
|
||
Description: "Beim Einrichten im reduzierten Betrieb fehlt eine unabhaengige Geschwindigkeitsueberwachung, so dass der Bediener nicht ausreichend geschuetzt ist.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62061", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Sicherheitsumrichter mit SLS", "Unabhaengige Drehzahlmessung", "SIL-2-Geschwindigkeitsueberwachung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_function_failure", 4),
|
||
Category: "safety_function_failure",
|
||
Name: "STO-Funktion (Safe Torque Off) Fehler",
|
||
Description: "Die STO-Sicherheitsfunktion schaltet den Antriebsmoment nicht ab, obwohl die Funktion aktiviert wurde, z.B. durch Fehler im Sicherheits-SPS-Ausgang.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"actuator", "controller"},
|
||
RegulationReferences: []string{"IEC 61800-5-2", "Maschinenverordnung 2023/1230", "IEC 62061"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"STO-Pruefung bei Inbetriebnahme", "Pruefzyklus im Betrieb", "Zertifizierter Sicherheitsumrichter"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_function_failure", 5),
|
||
Category: "safety_function_failure",
|
||
Name: "Muting-Missbrauch bei Lichtvorhang",
|
||
Description: "Die Muting-Funktion des Lichtvorhangs wird durch Fehler oder Manipulation zu lange oder unkontrolliert aktiviert, was den Schutz aufhebt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"sensor", "controller"},
|
||
RegulationReferences: []string{"IEC 61496-3", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Zeitbegrenztes Muting", "Muting-Lampe und Alarm", "Protokollierung der Muting-Ereignisse"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_function_failure", 6),
|
||
Category: "safety_function_failure",
|
||
Name: "Zweihand-Taster durch Gegenstand ueberbrueckt",
|
||
Description: "Die Zweihand-Betaetigungseinrichtung wird durch ein eingeklemmtes Objekt permanent aktiviert, was den Bediener aus dem Schutzkonzept loest.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"hmi", "controller"},
|
||
RegulationReferences: []string{"ISO 13851", "Maschinenverordnung 2023/1230", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Anti-Tie-Down-Pruefung", "Typ-III-Zweihand-Taster", "Regelmaessige Funktionskontrolle"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_function_failure", 7),
|
||
Category: "safety_function_failure",
|
||
Name: "Sicherheitsrelais-Ausfall ohne Erkennung",
|
||
Description: "Ein Sicherheitsrelais versagt unentdeckt (z.B. verklebte Kontakte), sodass der Sicherheitskreis nicht mehr auftrennt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"controller"},
|
||
RegulationReferences: []string{"ISO 13849", "IEC 62061"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Selbstueberwachung (zwangsgefuehrt)", "Regelmaessiger Testlauf", "Redundantes Relais"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("safety_function_failure", 8),
|
||
Category: "safety_function_failure",
|
||
Name: "Logic-Solver-Fehler in Sicherheits-SPS",
|
||
Description: "Die Sicherheitssteuerung (Safety-SPS) fuehrt sicherheitsrelevante Logik fehlerhaft aus, z.B. durch Speicherfehler oder Prozessorfehler.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 1,
|
||
ApplicableComponentTypes: []string{"controller", "software"},
|
||
RegulationReferences: []string{"IEC 61511", "IEC 61508", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"SIL-zertifizierte SPS", "Watchdog", "Selbsttest-Routinen (BIST)"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: logging_audit_failure (5 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("logging_audit_failure", 1),
|
||
Category: "logging_audit_failure",
|
||
Name: "Safety-Events nicht protokolliert",
|
||
Description: "Sicherheitsrelevante Ereignisse (Alarme, Not-Halt-Betaetigungen, Fehlerzustaende) werden nicht in ein Protokoll geschrieben.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62443", "CRA"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Pflicht-Logging Safety-Events", "Unveraenderliches Audit-Log", "Log-Integritaetspruefung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("logging_audit_failure", 2),
|
||
Category: "logging_audit_failure",
|
||
Name: "Log-Manipulation moeglich",
|
||
Description: "Authentifizierte Benutzer oder Angreifer koennen Protokolleintraege aendern oder loeschen und so Beweise fuer Sicherheitsvorfaelle vernichten.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software"},
|
||
RegulationReferences: []string{"CRA", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Write-Once-Speicher", "Kryptografische Signaturen", "Externes Log-Management"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("logging_audit_failure", 3),
|
||
Category: "logging_audit_failure",
|
||
Name: "Log-Overflow ueberschreibt alte Eintraege",
|
||
Description: "Wenn der Log-Speicher voll ist, werden aeltere Eintraege ohne Warnung ueberschrieben, was eine lueckenlose Rueckverfolgung verhindert.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
ApplicableComponentTypes: []string{"software", "controller"},
|
||
RegulationReferences: []string{"CRA", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Log-Kapazitaetsalarm", "Externes Log-System", "Zirkulaerpuffer mit Warnschwelle"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("logging_audit_failure", 4),
|
||
Category: "logging_audit_failure",
|
||
Name: "Fehlende Zeitstempel in Protokolleintraegen",
|
||
Description: "Log-Eintraege enthalten keine oder ungenaue Zeitstempel, was die zeitliche Rekonstruktion von Ereignissen bei der Fehlersuche verhindert.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "controller"},
|
||
RegulationReferences: []string{"CRA", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"NTP-Synchronisation", "RTC im Geraet", "ISO-8601-Zeitstempel"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("logging_audit_failure", 5),
|
||
Category: "logging_audit_failure",
|
||
Name: "Audit-Trail loeschbar durch Bediener",
|
||
Description: "Der Audit-Trail kann von einem normalen Bediener geloescht werden, was die Nachvollziehbarkeit von Sicherheitsereignissen untergaebt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software"},
|
||
RegulationReferences: []string{"CRA", "IEC 62443", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"RBAC: Nur Admin darf loeschen", "Log-Export vor Loeschung", "Unanderbare Log-Speicherung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: integration_error (8 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("integration_error", 1),
|
||
Category: "integration_error",
|
||
Name: "Datentyp-Mismatch an Schnittstelle",
|
||
Description: "Zwei Systeme tauschen Daten ueber eine Schnittstelle aus, die inkompatible Datentypen verwendet, was zu Interpretationsfehlern fuehrt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "network"},
|
||
RegulationReferences: []string{"IEC 62304", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schnittstellendefinition (IDL/Protobuf)", "Integrationstests", "Datentypvalidierung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("integration_error", 2),
|
||
Category: "integration_error",
|
||
Name: "Endianness-Fehler bei Datenuebertragung",
|
||
Description: "Big-Endian- und Little-Endian-Systeme kommunizieren ohne Byte-Order-Konvertierung, was zu falsch interpretierten numerischen Werten fuehrt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "network"},
|
||
RegulationReferences: []string{"IEC 62304", "IEC 62443"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Explizite Byte-Order-Definiton", "Integrationstests", "Schnittstellenspezifikation"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("integration_error", 3),
|
||
Category: "integration_error",
|
||
Name: "Protokoll-Versions-Konflikt",
|
||
Description: "Sender und Empfaenger verwenden unterschiedliche Protokollversionen, die nicht rueckwaertskompatibel sind, was zu Paketablehnung oder Fehlinterpretation fuehrt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "network", "firmware"},
|
||
RegulationReferences: []string{"IEC 62443", "CRA"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Versions-Aushandlung beim Verbindungsaufbau", "Backward-Compatibilitaet", "Kompatibilitaets-Matrix"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("integration_error", 4),
|
||
Category: "integration_error",
|
||
Name: "Timeout nicht behandelt bei Kommunikation",
|
||
Description: "Eine Kommunikationsverbindung bricht ab oder antwortet nicht, der Sender erkennt dies nicht und wartet unendlich lang.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "network"},
|
||
RegulationReferences: []string{"IEC 62443", "Maschinenverordnung 2023/1230"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Timeout-Konfiguration", "Watchdog-Timer", "Fail-Safe bei Verbindungsverlust"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("integration_error", 5),
|
||
Category: "integration_error",
|
||
Name: "Buffer Overflow an Schnittstelle",
|
||
Description: "Eine Schnittstelle akzeptiert Eingaben, die groesser als der zugewiesene Puffer sind, was zu Speicher-Ueberschreibung und Kontrollfluss-Manipulation fuehrt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "firmware", "network"},
|
||
RegulationReferences: []string{"CRA", "IEC 62443", "IEC 62304"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Laengenvalidierung", "Sichere Puffer-Funktionen", "Statische Analyse (z.B. MISRA)"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("integration_error", 6),
|
||
Category: "integration_error",
|
||
Name: "Fehlender Heartbeat bei Safety-Verbindung",
|
||
Description: "Eine Safety-Kommunikationsverbindung sendet keinen periodischen Heartbeat, so dass ein stiller Ausfall (z.B. unterbrochenes Kabel) nicht erkannt wird.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"network", "software"},
|
||
RegulationReferences: []string{"IEC 61784-3", "ISO 13849", "IEC 62061"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Heartbeat-Protokoll", "Verbindungsueberwachung", "Safe-State bei Heartbeat-Ausfall"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("integration_error", 7),
|
||
Category: "integration_error",
|
||
Name: "Falscher Skalierungsfaktor bei Sensordaten",
|
||
Description: "Sensordaten werden mit einem falschen Faktor skaliert, was zu signifikant fehlerhaften Messwerten und moeglichen Fehlentscheidungen fuehrt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"sensor", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62304"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Kalibrierungspruefung", "Plausibilitaetstest", "Schnittstellendokumentation"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("integration_error", 8),
|
||
Category: "integration_error",
|
||
Name: "Einheitenfehler (mm vs. inch)",
|
||
Description: "Unterschiedliche Masseinheiten zwischen Systemen fuehren zu fehlerhaften Bewegungsbefehlen oder Werkzeugpositionierungen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"software", "hmi"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 62304"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Explizite Einheitendefinition", "Einheitenkonvertierung in der Schnittstelle", "Integrationstests"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: environmental_hazard (5 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("environmental_hazard", 1),
|
||
Category: "environmental_hazard",
|
||
Name: "Ausfall durch hohe Umgebungstemperatur",
|
||
Description: "Hohe Umgebungstemperaturen ueberschreiten die spezifizierten Grenzwerte der Elektronik oder Aktorik und fuehren zu Fehlfunktionen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"controller", "sensor"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Betriebstemperatur-Spezifikation einhalten", "Klimaanlagensystem", "Temperatursensor + Abschaltung"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("environmental_hazard", 2),
|
||
Category: "environmental_hazard",
|
||
Name: "Ausfall bei Tieftemperatur",
|
||
Description: "Sehr tiefe Temperaturen reduzieren die Viskositaet von Hydraulikfluessigkeiten, beeinflussen Elektronik und fuehren zu mechanischen Ausfaellen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"actuator", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Tieftemperatur-spezifizierte Komponenten", "Heizung im Schaltschrank", "Anlaeufroutine bei Kaeltestart"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("environmental_hazard", 3),
|
||
Category: "environmental_hazard",
|
||
Name: "Korrosion durch Feuchtigkeit",
|
||
Description: "Hohe Luftfeuchtigkeit oder Kondenswasser fuehrt zur Korrosion von Kontakten und Leiterbahnen, was zu Ausfaellen und Isolationsfehlern fuehrt.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
ApplicableComponentTypes: []string{"controller", "sensor"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60529"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"IP-Schutz entsprechend der Umgebung", "Belueftung mit Filter", "Regelmaessige Inspektion"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("environmental_hazard", 4),
|
||
Category: "environmental_hazard",
|
||
Name: "Fehlfunktion durch Vibrationen",
|
||
Description: "Mechanische Vibrationen lockern Verbindungen, schuetteln Kontakte auf oder beschaedigen Loetpunkte in Elektronikbaugruppen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"controller", "sensor"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60068-2-6"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Vibrationsdaempfung", "Vergossene Elektronik", "Regelmaessige Verbindungskontrolle"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("environmental_hazard", 5),
|
||
Category: "environmental_hazard",
|
||
Name: "Kontamination durch Staub oder Fluessigkeiten",
|
||
Description: "Staub, Metallspaeene oder Kuehlmittel gelangen in das Gehaeuseinnere und fuehren zu Kurzschluessen, Isolationsfehlern oder Kuehlproblemen.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
ApplicableComponentTypes: []string{"controller", "hmi"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "IEC 60529"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Hohe IP-Schutzklasse", "Dichtungen regelmaessig pruefen", "Ueberdruck im Schaltschrank"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
|
||
// ====================================================================
|
||
// Category: maintenance_hazard (6 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("maintenance_hazard", 1),
|
||
Category: "maintenance_hazard",
|
||
Name: "Wartung ohne LOTO-Prozedur",
|
||
Description: "Wartungsarbeiten werden ohne korrekte Lockout/Tagout-Prozedur durchgefuehrt, sodass die Maschine waehrend der Arbeit anlaufen kann.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
ApplicableComponentTypes: []string{"controller", "software"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"LOTO-Funktion in Software", "Schulung", "Prozedur im Betriebshandbuch"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("maintenance_hazard", 2),
|
||
Category: "maintenance_hazard",
|
||
Name: "Fehlende LOTO-Funktion in Software",
|
||
Description: "Die Steuerungssoftware bietet keine Moeglichkeit, die Maschine fuer Wartungsarbeiten sicher zu sperren und zu verriegeln.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "hmi"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Software-LOTO implementieren", "Wartungsmodus mit Schluessel", "Energiesperrfunktion"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("maintenance_hazard", 3),
|
||
Category: "maintenance_hazard",
|
||
Name: "Wartung bei laufender Maschine",
|
||
Description: "Wartungsarbeiten werden an betriebener Maschine durchgefuehrt, weil kein erzwungener Wartungsmodus vorhanden ist.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Erzwungenes Abschalten fuer Wartungsmodus", "Schluesselschalter", "Schutzmassnahmen im Wartungsmodus"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("maintenance_hazard", 4),
|
||
Category: "maintenance_hazard",
|
||
Name: "Wartungs-Tool ohne Zugangskontrolle",
|
||
Description: "Ein Diagnose- oder Wartungswerkzeug ist ohne Authentifizierung zugaenglich und ermoeglicht die unbeaufsichtigte Aenderung von Sicherheitsparametern.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "hmi"},
|
||
RegulationReferences: []string{"IEC 62443", "CRA"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Authentifizierung fuer Wartungs-Tools", "Rollenkonzept", "Audit-Log fuer Wartungszugriffe"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("maintenance_hazard", 5),
|
||
Category: "maintenance_hazard",
|
||
Name: "Unsichere Demontage gefaehrlicher Baugruppen",
|
||
Description: "Die Betriebsanleitung beschreibt nicht, wie gefaehrliche Baugruppen (z.B. Hochvolt, gespeicherte Energie) sicher demontiert werden.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.7.4"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Detaillierte Demontageanleitung", "Warnhinweise an Geraet", "Schulung des Wartungspersonals"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("maintenance_hazard", 6),
|
||
Category: "maintenance_hazard",
|
||
Name: "Wiederanlauf nach Wartung ohne Freigabeprozedur",
|
||
Description: "Nach Wartungsarbeiten wird die Maschine ohne formelle Freigabeprozedur wieder in Betrieb genommen, was zu Verletzungen bei noch anwesendem Personal fuehren kann.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
ApplicableComponentTypes: []string{"software", "hmi"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I §1.6.3", "ISO 13849"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Software-Wiederanlauf-Freigabe", "Gefahrenbereich-Pruefung vor Anlauf", "Akustisches Warnsignal vor Anlauf"}),
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
}
|
||
|
||
entries = append(entries, extended...)
|
||
|
||
// ====================================================================
|
||
// ISO 12100 Machine Safety Hazard Extensions (~54 entries)
|
||
// ====================================================================
|
||
|
||
iso12100Entries := []HazardLibraryEntry{
|
||
// ====================================================================
|
||
// Category: mechanical_hazard (indices 7-20, 14 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 7),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "quetschgefahr",
|
||
Name: "Quetschgefahr durch gegenlaeufige Walzen",
|
||
Description: "Zwischen gegenlaeufig rotierenden Walzen entsteht ein Einzugspunkt, an dem Koerperteile oder Kleidung eingezogen und gequetscht werden koennen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Feststehende trennende Schutzeinrichtung am Walzeneinlauf", "Zweihandbedienung bei manueller Beschickung"}),
|
||
TypicalCauses: []string{"Fehlende Schutzabdeckung am Einzugspunkt", "Manuelle Materialzufuehrung ohne Hilfsmittel", "Wartung bei laufender Maschine"},
|
||
TypicalHarm: "Quetschverletzungen an Fingern, Haenden oder Armen bis hin zu Amputationen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Mindestabstand zwischen Walzen groesser als 25 mm oder kleiner als 5 mm", "Einzugspunkt ausserhalb der Reichweite positionieren"},
|
||
RecommendedMeasuresTechnical: []string{"Schutzgitter mit Sicherheitsverriegelung", "Lichtschranke vor dem Einzugsbereich"},
|
||
RecommendedMeasuresInformation: []string{"Warnschilder am Einzugspunkt", "Betriebsanweisung zur sicheren Beschickung"},
|
||
SuggestedEvidence: []string{"Pruefbericht der Schutzeinrichtung", "Risikobeurteilung nach ISO 12100"},
|
||
RelatedKeywords: []string{"Walzen", "Einzugspunkt", "Quetschstelle"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 8),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "schergefahr",
|
||
Name: "Schergefahr an beweglichen Maschinenteilen",
|
||
Description: "Durch gegeneinander bewegte Maschinenteile entstehen Scherstellen, die zu schweren Schnitt- und Trennverletzungen fuehren koennen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Trennende Schutzeinrichtung an der Scherstelle", "Sicherheitsabstand nach ISO 13857"}),
|
||
TypicalCauses: []string{"Unzureichender Sicherheitsabstand", "Fehlende Schutzverkleidung", "Eingriff waehrend des Betriebs"},
|
||
TypicalHarm: "Schnitt- und Trennverletzungen an Fingern und Haenden",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Sicherheitsabstaende nach ISO 13857 einhalten", "Scherstellen konstruktiv vermeiden"},
|
||
RecommendedMeasuresTechnical: []string{"Verriegelte Schutzhauben", "Not-Halt in unmittelbarer Naehe"},
|
||
RecommendedMeasuresInformation: []string{"Gefahrenhinweis an Scherstellen", "Schulung der Bediener"},
|
||
SuggestedEvidence: []string{"Abstandsmessung gemaess ISO 13857", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Scherstelle", "Gegenlaeufig", "Schneidgefahr"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 9),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "schneidgefahr",
|
||
Name: "Schneidgefahr durch rotierende Werkzeuge",
|
||
Description: "Rotierende Schneidwerkzeuge wie Fraeser, Saegeblaetter oder Messer koennen bei Kontakt schwere Schnittverletzungen verursachen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Vollstaendige Einhausung des Werkzeugs", "Automatische Werkzeugbremse bei Schutztueroeffnung"}),
|
||
TypicalCauses: []string{"Offene Schutzhaube waehrend des Betriebs", "Nachlauf des Werkzeugs nach Abschaltung", "Werkzeugbruch"},
|
||
TypicalHarm: "Tiefe Schnittwunden bis hin zu Gliedmassentrennung",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Vollstaendige Einhausung mit Verriegelung", "Werkzeugbremse mit kurzer Nachlaufzeit"},
|
||
RecommendedMeasuresTechnical: []string{"Verriegelte Schutzhaube mit Zuhaltung", "Drehzahlueberwachung"},
|
||
RecommendedMeasuresInformation: []string{"Warnhinweis zur Nachlaufzeit", "Betriebsanweisung zum Werkzeugwechsel"},
|
||
SuggestedEvidence: []string{"Nachlaufzeitmessung", "Pruefbericht Schutzeinrichtung"},
|
||
RelatedKeywords: []string{"Fraeser", "Saegeblatt", "Schneidwerkzeug"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 10),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "einzugsgefahr",
|
||
Name: "Einzugsgefahr durch Foerderbaender",
|
||
Description: "An Umlenkrollen und Antriebstrommeln von Foerderbaendern bestehen Einzugsstellen, die Koerperteile oder Kleidung erfassen koennen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schutzverkleidung an Umlenkrollen", "Not-Halt-Reissleine entlang des Foerderbands"}),
|
||
TypicalCauses: []string{"Fehlende Abdeckung an Umlenkpunkten", "Reinigung bei laufendem Band", "Lose Kleidung des Personals"},
|
||
TypicalHarm: "Einzugsverletzungen an Armen und Haenden, Quetschungen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "cleaning", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Umlenkrollen mit Schutzverkleidung", "Unterflur-Foerderung wo moeglich"},
|
||
RecommendedMeasuresTechnical: []string{"Not-Halt-Reissleine", "Bandschieflauf-Erkennung"},
|
||
RecommendedMeasuresInformation: []string{"Kleidervorschrift fuer Bedienpersonal", "Sicherheitsunterweisung"},
|
||
SuggestedEvidence: []string{"Pruefbericht der Schutzeinrichtungen", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Foerderband", "Umlenkrolle", "Einzugsstelle"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 11),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "erfassungsgefahr",
|
||
Name: "Erfassungsgefahr durch rotierende Wellen",
|
||
Description: "Freiliegende rotierende Wellen, Kupplungen oder Zapfen koennen Kleidung oder Haare erfassen und Personen in die Drehbewegung hineinziehen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Vollstaendige Verkleidung rotierender Wellen", "Drehmomentbegrenzung"}),
|
||
TypicalCauses: []string{"Fehlende Wellenabdeckung", "Lose Kleidungsstuecke", "Wartung bei laufender Welle"},
|
||
TypicalHarm: "Erfassungsverletzungen mit Knochenbruechen, Skalpierungen oder toedlichem Ausgang",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Wellen vollstaendig einhausen", "Kupplungen mit Schutzhuelsen"},
|
||
RecommendedMeasuresTechnical: []string{"Verriegelte Schutzabdeckung", "Stillstandsueberwachung fuer Wartungszugang"},
|
||
RecommendedMeasuresInformation: []string{"Kleiderordnung ohne lose Teile", "Warnschilder an Wellenabdeckungen"},
|
||
SuggestedEvidence: []string{"Inspektionsbericht Wellenabdeckungen", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Welle", "Kupplung", "Erfassung"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 12),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "stossgefahr",
|
||
Name: "Stossgefahr durch pneumatische/hydraulische Zylinder",
|
||
Description: "Schnell ausfahrende Pneumatik- oder Hydraulikzylinder koennen Personen stossen oder einklemmen, insbesondere bei unerwartetem Anlauf.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"actuator", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Geschwindigkeitsbegrenzung durch Drosselventile", "Schutzeinrichtung im Bewegungsbereich"}),
|
||
TypicalCauses: []string{"Fehlende Endlagendaempfung", "Unerwarteter Druckaufbau", "Aufenthalt im Bewegungsbereich"},
|
||
TypicalHarm: "Prellungen, Knochenbrueche, Einklemmverletzungen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Endlagendaempfung vorsehen", "Zylindergeschwindigkeit begrenzen"},
|
||
RecommendedMeasuresTechnical: []string{"Lichtvorhang im Bewegungsbereich", "Druckspeicher-Entlastungsventil"},
|
||
RecommendedMeasuresInformation: []string{"Kennzeichnung des Bewegungsbereichs", "Betriebsanweisung"},
|
||
SuggestedEvidence: []string{"Geschwindigkeitsmessung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Zylinder", "Pneumatik", "Stossgefahr"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 13),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "herabfallende_teile",
|
||
Name: "Herabfallende Teile aus Werkstueckhalterung",
|
||
Description: "Unzureichend gesicherte Werkstuecke oder Werkzeuge koennen sich aus der Halterung loesen und herabfallen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Spannkraftueberwachung der Halterung", "Schutzdach ueber dem Bedienerbereich"}),
|
||
TypicalCauses: []string{"Unzureichende Spannkraft", "Vibration lockert die Halterung", "Falsches Werkstueck-Spannmittel"},
|
||
TypicalHarm: "Kopfverletzungen, Prellungen, Quetschungen durch herabfallende Teile",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Spannkraftueberwachung mit Abschaltung", "Auffangvorrichtung unter Werkstueck"},
|
||
RecommendedMeasuresTechnical: []string{"Sensor zur Spannkraftueberwachung", "Schutzhaube"},
|
||
RecommendedMeasuresInformation: []string{"Pruefanweisung vor Bearbeitungsstart", "Schutzhelmpflicht im Gefahrenbereich"},
|
||
SuggestedEvidence: []string{"Pruefprotokoll Spannmittel", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Werkstueck", "Spannmittel", "Herabfallen"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 14),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "wegschleudern",
|
||
Name: "Wegschleudern von Bruchstuecken bei Werkzeugversagen",
|
||
Description: "Bei Werkzeugbruch koennen Bruchstuecke mit hoher Geschwindigkeit weggeschleudert werden und Personen im Umfeld verletzen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Splitterschutzscheibe aus Polycarbonat", "Regelmaessige Werkzeuginspektion"}),
|
||
TypicalCauses: []string{"Werkzeugverschleiss", "Ueberschreitung der zulaessigen Drehzahl", "Materialfehler im Werkzeug"},
|
||
TypicalHarm: "Durchdringende Verletzungen durch Bruchstuecke, Augenverletzungen",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Splitterschutz in der Einhausung", "Drehzahlbegrenzung des Werkzeugs"},
|
||
RecommendedMeasuresTechnical: []string{"Unwuchtueberwachung", "Brucherkennungssensor"},
|
||
RecommendedMeasuresInformation: []string{"Maximaldrehzahl am Werkzeug kennzeichnen", "Schutzbrillenpflicht"},
|
||
SuggestedEvidence: []string{"Bersttest der Einhausung", "Werkzeuginspektionsprotokoll"},
|
||
RelatedKeywords: []string{"Werkzeugbruch", "Splitter", "Schleudern"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 15),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "instabilitaet",
|
||
Name: "Instabilitaet der Maschine durch fehlendes Fundament",
|
||
Description: "Eine unzureichend verankerte oder falsch aufgestellte Maschine kann kippen oder sich verschieben, insbesondere bei dynamischen Kraeften.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Fundamentberechnung und Verankerung", "Standsicherheitsnachweis"}),
|
||
TypicalCauses: []string{"Fehlende Bodenverankerung", "Ungeeigneter Untergrund", "Erhoehte dynamische Lasten"},
|
||
TypicalHarm: "Quetschverletzungen durch kippende Maschine, Sachschaeden",
|
||
RelevantLifecyclePhases: []string{"installation", "normal_operation", "transport"},
|
||
RecommendedMeasuresDesign: []string{"Niedriger Schwerpunkt der Maschine", "Befestigungspunkte im Maschinenrahmen"},
|
||
RecommendedMeasuresTechnical: []string{"Bodenverankerung mit Schwerlastduebeln", "Nivellierelemente mit Kippsicherung"},
|
||
RecommendedMeasuresInformation: []string{"Aufstellanleitung mit Fundamentplan", "Hinweis auf maximale Bodenbelastung"},
|
||
SuggestedEvidence: []string{"Standsicherheitsnachweis", "Fundamentplan"},
|
||
RelatedKeywords: []string{"Fundament", "Standsicherheit", "Kippen"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 16),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "wiederanlauf",
|
||
Name: "Unkontrollierter Wiederanlauf nach Energieunterbruch",
|
||
Description: "Nach einem Stromausfall oder Druckabfall kann die Maschine unkontrolliert wieder anlaufen und Personen im Gefahrenbereich verletzen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"mechanical", "controller", "electrical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Wiederanlaufsperre nach Energierueckkehr", "Quittierungspflichtiger Neustart"}),
|
||
TypicalCauses: []string{"Fehlende Wiederanlaufsperre", "Stromausfall mit anschliessendem automatischem Neustart", "Druckaufbau nach Leckagereparatur"},
|
||
TypicalHarm: "Verletzungen durch unerwartete Maschinenbewegung bei Wiederanlauf",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance", "fault_finding"},
|
||
RecommendedMeasuresDesign: []string{"Wiederanlaufsperre in der Steuerung", "Energiespeicher sicher entladen"},
|
||
RecommendedMeasuresTechnical: []string{"Schaltschuetz mit Selbsthaltung", "Druckschalter mit Ruecksetzbedingung"},
|
||
RecommendedMeasuresInformation: []string{"Hinweis auf Wiederanlaufverhalten", "Verfahrensanweisung nach Energieausfall"},
|
||
SuggestedEvidence: []string{"Funktionstest Wiederanlaufsperre", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Wiederanlauf", "Stromausfall", "Anlaufsperre"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 17),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "reibungsgefahr",
|
||
Name: "Reibungsgefahr an rauen Oberflaechen",
|
||
Description: "Raue, scharfkantige oder gratbehaftete Maschinenoberlaechen koennen bei Kontakt zu Hautabschuerfungen und Schnittverletzungen fuehren.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 4,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Entgraten aller zugaenglichen Kanten", "Schutzhandschuhe fuer Bedienpersonal"}),
|
||
TypicalCauses: []string{"Nicht entgratete Schnittkanten", "Korrosionsraue Oberflaechen", "Verschleissbedingter Materialabtrag"},
|
||
TypicalHarm: "Hautabschuerfungen, Schnittverletzungen an Haenden und Armen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Kanten brechen oder abrunden", "Glatte Oberflaechen an Kontaktstellen"},
|
||
RecommendedMeasuresTechnical: []string{"Kantenschutzprofile anbringen"},
|
||
RecommendedMeasuresInformation: []string{"Hinweis auf scharfe Kanten", "Handschuhpflicht in der Betriebsanweisung"},
|
||
SuggestedEvidence: []string{"Oberflaechenpruefung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Grat", "Scharfkantig", "Oberflaeche"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 18),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "hochdruckstrahl",
|
||
Name: "Fluessigkeitshochdruckstrahl",
|
||
Description: "Hochdruckstrahlen aus Hydraulik-, Kuehl- oder Reinigungssystemen koennen Haut durchdringen und schwere Gewebeschaeden verursachen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Abschirmung von Hochdruckleitungen", "Regelmaessige Leitungsinspektion"}),
|
||
TypicalCauses: []string{"Leitungsbruch unter Hochdruck", "Undichte Verschraubungen", "Alterung von Schlauchleitungen"},
|
||
TypicalHarm: "Hochdruckinjektionsverletzungen, Gewebsnekrose",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Schlauchbruchsicherungen einbauen", "Leitungen ausserhalb des Aufenthaltsbereichs verlegen"},
|
||
RecommendedMeasuresTechnical: []string{"Druckabschaltung bei Leitungsbruch", "Schutzblechverkleidung"},
|
||
RecommendedMeasuresInformation: []string{"Warnhinweis an Hochdruckleitungen", "Prueffristen fuer Schlauchleitungen"},
|
||
SuggestedEvidence: []string{"Druckpruefprotokoll", "Inspektionsbericht Schlauchleitungen"},
|
||
RelatedKeywords: []string{"Hochdruck", "Hydraulikleitung", "Injection"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 19),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "federelemente",
|
||
Name: "Gefahr durch federgespannte Elemente",
|
||
Description: "Unter Spannung stehende Federn oder elastische Elemente koennen bei unkontrolliertem Loesen Teile wegschleudern oder Personen verletzen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Gesicherte Federentspannung vor Demontage", "Warnung bei vorgespannten Elementen"}),
|
||
TypicalCauses: []string{"Demontage ohne vorherige Entspannung", "Materialermuedung der Feder", "Fehlende Kennzeichnung vorgespannter Elemente"},
|
||
TypicalHarm: "Verletzungen durch wegschleudernde Federelemente, Prellungen",
|
||
RelevantLifecyclePhases: []string{"maintenance", "decommissioning"},
|
||
RecommendedMeasuresDesign: []string{"Sichere Entspannungsmoeglichkeit vorsehen", "Federn mit Bruchsicherung"},
|
||
RecommendedMeasuresTechnical: []string{"Spezialwerkzeug zur Federentspannung"},
|
||
RecommendedMeasuresInformation: []string{"Kennzeichnung vorgespannter Elemente", "Wartungsanweisung mit Entspannungsprozedur"},
|
||
SuggestedEvidence: []string{"Wartungsanweisung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Feder", "Vorspannung", "Energiespeicher"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("mechanical_hazard", 20),
|
||
Category: "mechanical_hazard",
|
||
SubCategory: "schutztor",
|
||
Name: "Quetschgefahr im Schliessbereich von Schutztoren",
|
||
Description: "Automatisch schliessende Schutztore und -tueren koennen Personen im Schliessbereich einklemmen oder quetschen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator", "sensor"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schliesskantensicherung mit Kontaktleiste", "Lichtschranke im Schliessbereich"}),
|
||
TypicalCauses: []string{"Fehlende Schliesskantensicherung", "Defekter Sensor", "Person im Schliessbereich nicht erkannt"},
|
||
TypicalHarm: "Quetschverletzungen an Koerper oder Gliedmassen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Schliesskraftbegrenzung", "Reversierautomatik bei Hindernis"},
|
||
RecommendedMeasuresTechnical: []string{"Kontaktleiste an der Schliesskante", "Lichtschranke im Durchgangsbereich"},
|
||
RecommendedMeasuresInformation: []string{"Warnhinweis am Schutztor", "Automatik-Betrieb kennzeichnen"},
|
||
SuggestedEvidence: []string{"Schliesskraftmessung", "Funktionstest Reversierautomatik"},
|
||
RelatedKeywords: []string{"Schutztor", "Schliesskante", "Einklemmen"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
// ====================================================================
|
||
// Category: electrical_hazard (indices 7-10, 4 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 7),
|
||
Category: "electrical_hazard",
|
||
SubCategory: "lichtbogen",
|
||
Name: "Lichtbogengefahr bei Schalthandlungen",
|
||
Description: "Beim Schalten unter Last kann ein Lichtbogen entstehen, der zu Verbrennungen und Augenschaeden fuehrt.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"electrical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Lichtbogenschutzkleidung (PSA)", "Fernbediente Schaltgeraete"}),
|
||
TypicalCauses: []string{"Schalten unter Last", "Verschmutzte Kontakte", "Fehlbedienung bei Wartung"},
|
||
TypicalHarm: "Verbrennungen durch Lichtbogen, Augenschaeden, Druckwelle",
|
||
RelevantLifecyclePhases: []string{"maintenance", "fault_finding"},
|
||
RecommendedMeasuresDesign: []string{"Lasttrennschalter mit Lichtbogenkammer", "Beruerungssichere Klemmleisten"},
|
||
RecommendedMeasuresTechnical: []string{"Lichtbogen-Erkennungssystem", "Fernausloesemoeglichkeit"},
|
||
RecommendedMeasuresInformation: []string{"PSA-Pflicht bei Schalthandlungen", "Schaltbefugnisregelung"},
|
||
SuggestedEvidence: []string{"Lichtbogenberechnung", "PSA-Ausstattungsnachweis"},
|
||
RelatedKeywords: []string{"Lichtbogen", "Schalthandlung", "Arc Flash"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 8),
|
||
Category: "electrical_hazard",
|
||
SubCategory: "ueberstrom",
|
||
Name: "Ueberstrom durch Kurzschluss",
|
||
Description: "Ein Kurzschluss kann zu extrem hohen Stroemen fuehren, die Leitungen ueberhitzen, Braende ausloesen und Bauteile zerstoeren.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"electrical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Selektive Absicherung mit Schmelzsicherungen", "Kurzschlussberechnung und Abschaltzeitnachweis"}),
|
||
TypicalCauses: []string{"Beschaedigte Leitungsisolierung", "Feuchtigkeitseintritt", "Fehlerhafte Verdrahtung"},
|
||
TypicalHarm: "Brandgefahr, Zerstoerung elektrischer Betriebsmittel",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance", "installation"},
|
||
RecommendedMeasuresDesign: []string{"Kurzschlussfeste Dimensionierung der Leitungen", "Selektive Schutzkoordination"},
|
||
RecommendedMeasuresTechnical: []string{"Leitungsschutzschalter", "Fehlerstrom-Schutzeinrichtung"},
|
||
RecommendedMeasuresInformation: []string{"Stromlaufplan aktuell halten", "Prueffristen fuer elektrische Anlage"},
|
||
SuggestedEvidence: []string{"Kurzschlussberechnung", "Pruefprotokoll nach DGUV V3"},
|
||
RelatedKeywords: []string{"Kurzschluss", "Ueberstrom", "Leitungsschutz"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 9),
|
||
Category: "electrical_hazard",
|
||
SubCategory: "erdungsfehler",
|
||
Name: "Erdungsfehler im Schutzleitersystem",
|
||
Description: "Ein unterbrochener oder fehlerhafter Schutzleiter verhindert die sichere Ableitung von Fehlerstroemen und macht Gehaeuse spannungsfuehrend.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"electrical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Regelmaessige Schutzleiterpruefung", "Fehlerstrom-Schutzschalter als Zusatzmassnahme"}),
|
||
TypicalCauses: []string{"Lose Schutzleiterklemme", "Korrosion an Erdungspunkten", "Vergessener Schutzleiteranschluss nach Wartung"},
|
||
TypicalHarm: "Elektrischer Schlag bei Beruehrung des Maschinengehaeuses",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance", "installation"},
|
||
RecommendedMeasuresDesign: []string{"Redundante Schutzleiteranschluesse", "Schutzleiter-Monitoring"},
|
||
RecommendedMeasuresTechnical: []string{"RCD-Schutzschalter 30 mA", "Isolationsueberwachung"},
|
||
RecommendedMeasuresInformation: []string{"Pruefplaketten an Schutzleiterpunkten", "Prueffrist 12 Monate"},
|
||
SuggestedEvidence: []string{"Schutzleitermessung", "Pruefprotokoll DGUV V3"},
|
||
RelatedKeywords: []string{"Schutzleiter", "Erdung", "Fehlerstrom"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("electrical_hazard", 10),
|
||
Category: "electrical_hazard",
|
||
SubCategory: "isolationsversagen",
|
||
Name: "Isolationsversagen in Hochspannungsbereich",
|
||
Description: "Alterung, Verschmutzung oder mechanische Beschaedigung der Isolierung in Hochspannungsbereichen kann zu Spannungsueberschlaegen und Koerperdurchstroemung fuehren.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"electrical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Isolationswiderstandsmessung", "Spannungsfeste Einhausung"}),
|
||
TypicalCauses: []string{"Alterung der Isolierstoffe", "Mechanische Beschaedigung", "Verschmutzung und Feuchtigkeit"},
|
||
TypicalHarm: "Toedlicher Stromschlag, Verbrennungen durch Spannungsueberschlag",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Verstaerkte Isolierung in kritischen Bereichen", "Luftstrecken und Kriechstrecken einhalten"},
|
||
RecommendedMeasuresTechnical: []string{"Isolationsueberwachungsgeraet", "Verriegelter Zugang zum Hochspannungsbereich"},
|
||
RecommendedMeasuresInformation: []string{"Hochspannungswarnung", "Zutrittsregelung fuer Elektrofachkraefte"},
|
||
SuggestedEvidence: []string{"Isolationsmessprotokoll", "Pruefbericht Hochspannungsbereich"},
|
||
RelatedKeywords: []string{"Isolation", "Hochspannung", "Durchschlag"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
// ====================================================================
|
||
// Category: thermal_hazard (indices 5-8, 4 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("thermal_hazard", 5),
|
||
Category: "thermal_hazard",
|
||
SubCategory: "kaeltekontakt",
|
||
Name: "Kontakt mit kalten Oberflaechen (Kryotechnik)",
|
||
Description: "In kryotechnischen Anlagen oder Kuehlsystemen koennen extrem kalte Oberflaechen bei Beruehrung Kaelteverbrennungen verursachen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Isolierung kalter Oberflaechen", "Kaelteschutzhandschuhe"}),
|
||
TypicalCauses: []string{"Fehlende Isolierung an Kryoleitungen", "Beruehrung tiefgekuehlter Bauteile", "Defekte Kaelteisolierung"},
|
||
TypicalHarm: "Kaelteverbrennungen an Haenden und Fingern",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Isolierung aller kalten Oberflaechen im Zugriffsbereich", "Abstandshalter zu Kryoleitungen"},
|
||
RecommendedMeasuresTechnical: []string{"Temperaturwarnung bei kritischen Oberflaechentemperaturen"},
|
||
RecommendedMeasuresInformation: []string{"Warnhinweis Kaeltegefahr", "PSA-Pflicht Kaelteschutz"},
|
||
SuggestedEvidence: []string{"Oberflaechentemperaturmessung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Kryotechnik", "Kaelte", "Kaelteverbrennung"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("thermal_hazard", 6),
|
||
Category: "thermal_hazard",
|
||
SubCategory: "waermestrahlung",
|
||
Name: "Waermestrahlung von Hochtemperaturprozessen",
|
||
Description: "Oefen, Giessereianlagen oder Waermebehandlungsprozesse emittieren intensive Waermestrahlung, die auch ohne direkten Kontakt zu Verbrennungen fuehren kann.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Waermeschutzschilder", "Hitzeschutzkleidung"}),
|
||
TypicalCauses: []string{"Offene Ofentuer bei Beschickung", "Fehlende Abschirmung", "Langzeitexposition in der Naehe von Waermequellen"},
|
||
TypicalHarm: "Hautverbrennungen durch Waermestrahlung, Hitzschlag",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Waermedaemmung und Strahlungsschilde", "Automatische Beschickung statt manueller"},
|
||
RecommendedMeasuresTechnical: []string{"Waermestrahlung-Sensor mit Warnung", "Luftschleier vor Ofenoeeffnungen"},
|
||
RecommendedMeasuresInformation: []string{"Maximalaufenthaltsdauer festlegen", "Hitzeschutz-PSA vorschreiben"},
|
||
SuggestedEvidence: []string{"Waermestrahlungsmessung am Arbeitsplatz", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Waermestrahlung", "Ofen", "Hitzeschutz"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("thermal_hazard", 7),
|
||
Category: "thermal_hazard",
|
||
SubCategory: "brandgefahr",
|
||
Name: "Brandgefahr durch ueberhitzte Antriebe",
|
||
Description: "Ueberlastete oder schlecht gekuehlte Elektromotoren und Antriebe koennen sich so stark erhitzen, dass umgebende Materialien entzuendet werden.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"actuator", "electrical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Temperatursensor am Motor", "Thermischer Motorschutz"}),
|
||
TypicalCauses: []string{"Dauerbetrieb ueber Nennlast", "Blockierter Kuehlluftstrom", "Defektes Motorlager erhoecht Reibung"},
|
||
TypicalHarm: "Brand mit Sachschaeden und Personengefaehrdung durch Rauchentwicklung",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Thermische Motorschutzdimensionierung", "Brandschottung um Antriebsbereich"},
|
||
RecommendedMeasuresTechnical: []string{"PTC-Temperaturfuehler im Motor", "Rauchmelder im Antriebsbereich"},
|
||
RecommendedMeasuresInformation: []string{"Wartungsintervalle fuer Kuehlluftwege", "Brandschutzordnung"},
|
||
SuggestedEvidence: []string{"Temperaturmessung unter Last", "Brandschutzkonzept"},
|
||
RelatedKeywords: []string{"Motorueberhitzung", "Brand", "Thermischer Schutz"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("thermal_hazard", 8),
|
||
Category: "thermal_hazard",
|
||
SubCategory: "heisse_fluessigkeiten",
|
||
Name: "Verbrennungsgefahr durch heisse Fluessigkeiten",
|
||
Description: "Heisse Prozessfluessigkeiten, Kuehlmittel oder Dampf koennen bei Leckage oder beim Oeffnen von Verschluessen Verbruehungen verursachen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Druckentlastung vor dem Oeffnen", "Spritzschutz an Leitungsverbindungen"}),
|
||
TypicalCauses: []string{"Oeffnen von Verschluessen unter Druck", "Schlauchbruch bei heissem Medium", "Spritzer beim Nachfuellen"},
|
||
TypicalHarm: "Verbruehungen an Haut und Augen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Druckentlastungsventil vor Verschluss", "Isolierte Leitungsfuehrung"},
|
||
RecommendedMeasuresTechnical: []string{"Temperaturanzeige an kritischen Punkten", "Auffangwannen unter Leitungsverbindungen"},
|
||
RecommendedMeasuresInformation: []string{"Warnhinweis heisse Fluessigkeit", "Abkuehlprozedur in Betriebsanweisung"},
|
||
SuggestedEvidence: []string{"Temperaturmessung am Austritt", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Verbruehung", "Heisse Fluessigkeit", "Dampf"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
// ====================================================================
|
||
// Category: pneumatic_hydraulic (indices 1-10, 10 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 1),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "druckverlust",
|
||
Name: "Unkontrollierter Druckverlust in pneumatischem System",
|
||
Description: "Ein ploetzlicher Druckabfall im Pneumatiksystem kann zum Versagen von Halte- und Klemmfunktionen fuehren, wodurch Werkstuecke herabfallen oder Achsen absacken.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"actuator", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Rueckschlagventile in Haltezylinderleitungen", "Druckueberwachung mit sicherer Abschaltung"}),
|
||
TypicalCauses: []string{"Kompressorausfall", "Leckage in der Versorgungsleitung", "Fehlerhaftes Druckregelventil"},
|
||
TypicalHarm: "Quetschverletzungen durch absackende Achsen oder herabfallende Werkstuecke",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "fault_finding"},
|
||
RecommendedMeasuresDesign: []string{"Mechanische Haltebremsen als Rueckfallebene", "Rueckschlagventile in sicherheitsrelevanten Leitungen"},
|
||
RecommendedMeasuresTechnical: []string{"Druckwaechter mit sicherer Reaktion", "Druckspeicher fuer Notbetrieb"},
|
||
RecommendedMeasuresInformation: []string{"Warnung bei Druckabfall", "Verfahrensanweisung fuer Druckausfall"},
|
||
SuggestedEvidence: []string{"Druckabfalltest", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Druckverlust", "Pneumatik", "Haltefunktion"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 2),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "druckfreisetzung",
|
||
Name: "Ploetzliche Druckfreisetzung bei Leitungsbruch",
|
||
Description: "Ein Bersten oder Abreissen einer Druckleitung setzt schlagartig Energie frei, wobei Medien und Leitungsbruchstuecke weggeschleudert werden.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schlauchbruchsicherungen", "Druckfeste Leitungsverlegung"}),
|
||
TypicalCauses: []string{"Materialermuedung der Leitung", "Ueberdruckbetrieb", "Mechanische Beschaedigung der Leitung"},
|
||
TypicalHarm: "Verletzungen durch weggeschleuderte Leitungsteile und austretende Druckmedien",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Berstdruckfest dimensionierte Leitungen", "Leitungen in Schutzrohren verlegen"},
|
||
RecommendedMeasuresTechnical: []string{"Durchflussbegrenzer nach Druckquelle", "Schlauchbruchventile"},
|
||
RecommendedMeasuresInformation: []string{"Prueffristen fuer Druckleitungen", "Warnhinweis an Hochdruckbereichen"},
|
||
SuggestedEvidence: []string{"Druckpruefprotokoll", "Inspektionsbericht Leitungen"},
|
||
RelatedKeywords: []string{"Leitungsbruch", "Druckfreisetzung", "Bersten"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 3),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "schlauchpeitschen",
|
||
Name: "Schlauchpeitschen durch Berstversagen",
|
||
Description: "Ein unter Druck stehender Schlauch kann bei Versagen unkontrolliert umherschlagen und Personen im Umfeld treffen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Fangseile an Schlauchleitungen", "Schlauchbruchventile"}),
|
||
TypicalCauses: []string{"Alterung des Schlauchmaterials", "Knicke in der Schlauchfuehrung", "Falsche Schlauchtype fuer das Medium"},
|
||
TypicalHarm: "Peitschenverletzungen, Prellungen, Augenverletzungen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Fangseile oder Ketten an allen Schlauchleitungen", "Festverrohrung statt Schlauch wo moeglich"},
|
||
RecommendedMeasuresTechnical: []string{"Schlauchbruchventil am Anschluss"},
|
||
RecommendedMeasuresInformation: []string{"Tauschintervalle fuer Schlauchleitungen", "Kennzeichnung mit Herstelldatum"},
|
||
SuggestedEvidence: []string{"Schlauchleitungspruefprotokoll", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Schlauch", "Peitschen", "Fangseil"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 4),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "druckspeicherenergie",
|
||
Name: "Unerwartete Bewegung durch Druckspeicherrestenergie",
|
||
Description: "Nach dem Abschalten der Maschine kann in Druckspeichern verbliebene Energie unerwartete Bewegungen von Zylindern oder Aktoren verursachen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"actuator", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Automatische Druckspeicher-Entladung bei Abschaltung", "Sperrventile vor Aktoren"}),
|
||
TypicalCauses: []string{"Nicht entladener Druckspeicher", "Fehlendes Entlastungsventil", "Wartungszugriff ohne Druckfreischaltung"},
|
||
TypicalHarm: "Quetsch- und Stossverletzungen durch unerwartete Zylinderbewegung",
|
||
RelevantLifecyclePhases: []string{"maintenance", "fault_finding", "decommissioning"},
|
||
RecommendedMeasuresDesign: []string{"Automatische Speicherentladung bei Hauptschalter-Aus", "Manuelles Entlastungsventil mit Druckanzeige"},
|
||
RecommendedMeasuresTechnical: []string{"Druckmanometer am Speicher", "Verriegeltes Entlastungsventil"},
|
||
RecommendedMeasuresInformation: []string{"Warnschild Druckspeicher", "LOTO-Verfahren fuer Druckspeicher"},
|
||
SuggestedEvidence: []string{"Funktionstest Speicherentladung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Druckspeicher", "Restenergie", "Speicherentladung"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 5),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "oelkontamination",
|
||
Name: "Kontamination von Hydraulikoel durch Partikel",
|
||
Description: "Verunreinigungen im Hydraulikoel fuehren zu erhoehtem Verschleiss an Ventilen und Dichtungen, was Leckagen und Funktionsversagen ausloest.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 4,
|
||
ApplicableComponentTypes: []string{"actuator", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Feinfilterung des Hydraulikoels", "Regelmaessige Oelanalyse"}),
|
||
TypicalCauses: []string{"Verschleisspartikel im System", "Verschmutzte Nachfuellung", "Defekte Filterelemente"},
|
||
TypicalHarm: "Maschinenausfall mit Folgeverletzungen durch ploetzliches Versagen hydraulischer Funktionen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Mehrfachfiltration mit Bypass-Anzeige", "Geschlossener Nachfuellkreislauf"},
|
||
RecommendedMeasuresTechnical: []string{"Online-Partikelzaehler", "Differenzdruckanzeige am Filter"},
|
||
RecommendedMeasuresInformation: []string{"Oelwechselintervalle festlegen", "Sauberkeitsvorgaben fuer Nachfuellung"},
|
||
SuggestedEvidence: []string{"Oelanalysebericht", "Filterwechselprotokoll"},
|
||
RelatedKeywords: []string{"Hydraulikoel", "Kontamination", "Filtration"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 6),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "leckage",
|
||
Name: "Leckage an Hochdruckverbindungen",
|
||
Description: "Undichte Verschraubungen oder Dichtungen an Hochdruckverbindungen fuehren zu Medienaustritt, Rutschgefahr und moeglichen Hochdruckinjektionsverletzungen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Leckagefreie Verschraubungen verwenden", "Auffangwannen unter Verbindungsstellen"}),
|
||
TypicalCauses: []string{"Vibrationsbedingte Lockerung", "Alterung der Dichtungen", "Falsches Anzugsmoment"},
|
||
TypicalHarm: "Rutschverletzungen, Hochdruckinjektion bei feinem Oelstrahl",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Verschraubungen mit Sicherungsmitteln", "Leckage-Auffangvorrichtungen"},
|
||
RecommendedMeasuresTechnical: []string{"Fuellstandsueberwachung im Tank", "Leckagesensor"},
|
||
RecommendedMeasuresInformation: []string{"Sichtpruefung in Wartungsplan aufnehmen", "Hinweis auf Injektionsgefahr"},
|
||
SuggestedEvidence: []string{"Leckagepruefprotokoll", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Leckage", "Verschraubung", "Hochdruck"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 7),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "kavitation",
|
||
Name: "Kavitation in Hydraulikpumpe",
|
||
Description: "Dampfblasenbildung und deren Implosion in der Hydraulikpumpe fuehren zu Materialabtrag, Leistungsverlust und ploetzlichem Pumpenversagen.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 4,
|
||
ApplicableComponentTypes: []string{"actuator", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Korrekte Saughoehe einhalten", "Saugleitungsdimensionierung pruefen"}),
|
||
TypicalCauses: []string{"Zu kleine Saugleitung", "Verstopfter Saugfilter", "Zu hohe Oelviskositaet bei Kaelte"},
|
||
TypicalHarm: "Maschinenausfall durch Pumpenversagen mit moeglichen Folgeverletzungen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Saugleitung grosszuegig dimensionieren", "Ueberdruck-Zulaufsystem"},
|
||
RecommendedMeasuresTechnical: []string{"Vakuumanzeige an der Saugseite", "Temperaturueberwachung des Oels"},
|
||
RecommendedMeasuresInformation: []string{"Vorwaermverfahren bei Kaeltestart", "Wartungsintervall Saugfilter"},
|
||
SuggestedEvidence: []string{"Saugdruckmessung", "Pumpeninspektionsbericht"},
|
||
RelatedKeywords: []string{"Kavitation", "Hydraulikpumpe", "Saugleitung"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 8),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "ueberdruckversagen",
|
||
Name: "Ueberdruckversagen durch defektes Druckbegrenzungsventil",
|
||
Description: "Ein klemmendes oder falsch eingestelltes Druckbegrenzungsventil laesst den Systemdruck unkontrolliert ansteigen, was zum Bersten von Komponenten fuehren kann.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"actuator", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Redundantes Druckbegrenzungsventil", "Druckschalter mit Abschaltung"}),
|
||
TypicalCauses: []string{"Verschmutztes Druckbegrenzungsventil", "Falsche Einstellung nach Wartung", "Ermuedung der Ventilfeder"},
|
||
TypicalHarm: "Bersten von Leitungen und Gehaeusen mit Splitterwurf, Hochdruckinjektionsverletzungen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Redundante Druckbegrenzung", "Berstscheibe als letzte Sicherung"},
|
||
RecommendedMeasuresTechnical: []string{"Druckschalter mit sicherer Pumpenabschaltung", "Manometer mit Schleppzeiger"},
|
||
RecommendedMeasuresInformation: []string{"Pruefintervall Druckbegrenzungsventil", "Einstellprotokoll nach Wartung"},
|
||
SuggestedEvidence: []string{"Ventilpruefprotokoll", "Druckverlaufsmessung"},
|
||
RelatedKeywords: []string{"Ueberdruck", "Druckbegrenzungsventil", "Bersten"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 9),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "ventilversagen",
|
||
Name: "Unkontrollierte Zylinderbewegung bei Ventilversagen",
|
||
Description: "Bei Ausfall oder Fehlfunktion eines Wegeventils kann ein Zylinder unkontrolliert ein- oder ausfahren und Personen im Bewegungsbereich verletzen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"actuator", "controller"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Redundante Ventile fuer sicherheitskritische Achsen", "Lasthalteventile an Vertikalachsen"}),
|
||
TypicalCauses: []string{"Elektromagnetausfall am Ventil", "Ventilschieber klemmt", "Kontamination blockiert Ventilsitz"},
|
||
TypicalHarm: "Quetsch- und Stossverletzungen durch unkontrollierte Zylinderbewegung",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "fault_finding"},
|
||
RecommendedMeasuresDesign: []string{"Redundante Ventilanordnung mit Ueberwachung", "Lasthalteventile fuer schwerkraftbelastete Achsen"},
|
||
RecommendedMeasuresTechnical: []string{"Positionsueberwachung am Zylinder", "Ventil-Stellungsueberwachung"},
|
||
RecommendedMeasuresInformation: []string{"Fehlermeldung bei Ventildiskrepanz", "Notfallprozedur bei Ventilversagen"},
|
||
SuggestedEvidence: []string{"Funktionstest Redundanz", "FMEA Ventilschaltung"},
|
||
RelatedKeywords: []string{"Wegeventil", "Zylinderversagen", "Ventilausfall"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("pneumatic_hydraulic", 10),
|
||
Category: "pneumatic_hydraulic",
|
||
SubCategory: "viskositaet",
|
||
Name: "Temperaturbedingte Viskositaetsaenderung von Hydraulikmedium",
|
||
Description: "Extreme Temperaturen veraendern die Viskositaet des Hydraulikoels so stark, dass Ventile und Pumpen nicht mehr zuverlaessig arbeiten und Sicherheitsfunktionen versagen.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 2,
|
||
DefaultAvoidance: 4,
|
||
ApplicableComponentTypes: []string{"actuator", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Oeltemperierung", "Oelsorte mit breitem Viskositaetsbereich"}),
|
||
TypicalCauses: []string{"Kaltstart ohne Vorwaermung", "Ueberhitzung durch mangelnde Kuehlung", "Falsche Oelsorte"},
|
||
TypicalHarm: "Funktionsversagen hydraulischer Sicherheitseinrichtungen",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Oelkuehler und Oelheizung vorsehen", "Temperaturbereich der Oelsorte abstimmen"},
|
||
RecommendedMeasuresTechnical: []string{"Oeltemperatursensor mit Warnmeldung", "Aufwaermprogramm in der Steuerung"},
|
||
RecommendedMeasuresInformation: []string{"Zulaessiger Temperaturbereich in Betriebsanleitung", "Oelwechselvorschrift"},
|
||
SuggestedEvidence: []string{"Temperaturverlaufsmessung", "Oeldatenblatt"},
|
||
RelatedKeywords: []string{"Viskositaet", "Oeltemperatur", "Hydraulikmedium"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
// ====================================================================
|
||
// Category: noise_vibration (indices 1-6, 6 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("noise_vibration", 1),
|
||
Category: "noise_vibration",
|
||
SubCategory: "dauerschall",
|
||
Name: "Gehoerschaedigung durch Dauerschallpegel",
|
||
Description: "Dauerhaft erhoehte Schallpegel am Arbeitsplatz ueber dem Grenzwert fuehren zu irreversiblen Gehoerschaeden bei den Maschinenbedienern.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 4,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Laermminderung an der Quelle", "Gehoerschutzpflicht ab 85 dB(A)"}),
|
||
TypicalCauses: []string{"Nicht gekapselte Antriebe", "Metallische Schlagvorgaenge", "Fehlende Schalldaemmung"},
|
||
TypicalHarm: "Laermschwerhoerigkeit, Tinnitus",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Laermarme Antriebe und Getriebe", "Schwingungsdaempfende Lagerung"},
|
||
RecommendedMeasuresTechnical: []string{"Schallschutzkapseln", "Schallschutzwaende"},
|
||
RecommendedMeasuresInformation: []string{"Laermbereichskennzeichnung", "Gehoerschutzpflicht beschildern"},
|
||
SuggestedEvidence: []string{"Laermpegelmessung am Arbeitsplatz", "Laermkataster"},
|
||
RelatedKeywords: []string{"Laerm", "Gehoerschutz", "Schallpegel"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("noise_vibration", 2),
|
||
Category: "noise_vibration",
|
||
SubCategory: "hand_arm_vibration",
|
||
Name: "Hand-Arm-Vibrationssyndrom durch vibrierende Werkzeuge",
|
||
Description: "Langzeitige Nutzung handgefuehrter vibrierender Werkzeuge kann zu Durchblutungsstoerungen, Nervenschaeden und Gelenkbeschwerden in Haenden und Armen fuehren.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Vibrationsgedaempfte Werkzeuge verwenden", "Expositionszeit begrenzen"}),
|
||
TypicalCauses: []string{"Ungepufferte Handgriffe", "Verschlissene Werkzeuge mit erhoehter Vibration", "Fehlende Arbeitszeitbegrenzung"},
|
||
TypicalHarm: "Weissfingerkrankheit, Karpaltunnelsyndrom, Gelenkarthrose",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Vibrationsgedaempfte Griffe", "Automatisierung statt Handarbeit"},
|
||
RecommendedMeasuresTechnical: []string{"Vibrationsmessung am Werkzeug", "Anti-Vibrationshandschuhe"},
|
||
RecommendedMeasuresInformation: []string{"Expositionsdauer dokumentieren", "Arbeitsmedizinische Vorsorge anbieten"},
|
||
SuggestedEvidence: []string{"Vibrationsmessung nach ISO 5349", "Expositionsberechnung"},
|
||
RelatedKeywords: []string{"Vibration", "Hand-Arm", "HAVS"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("noise_vibration", 3),
|
||
Category: "noise_vibration",
|
||
SubCategory: "ganzkoerpervibration",
|
||
Name: "Ganzkoerpervibration an Bedienplaetzen",
|
||
Description: "Vibrationen, die ueber den Sitz oder die Standflaeche auf den gesamten Koerper uebertragen werden, koennen zu Wirbelsaeulenschaeden fuehren.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schwingungsisolierter Fahrersitz", "Vibrationsgedaempfte Stehplattform"}),
|
||
TypicalCauses: []string{"Unwucht in rotierenden Teilen", "Unebener Fahrweg", "Fehlende Schwingungsisolierung des Bedienplatzes"},
|
||
TypicalHarm: "Bandscheibenschaeden, Rueckenschmerzen, Ermuedung",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Schwingungsisolierte Kabine oder Plattform", "Auswuchten rotierender Massen"},
|
||
RecommendedMeasuresTechnical: []string{"Luftgefederter Sitz", "Vibrationsueberwachung mit Grenzwertwarnung"},
|
||
RecommendedMeasuresInformation: []string{"Maximalexpositionsdauer festlegen", "Arbeitsmedizinische Vorsorge"},
|
||
SuggestedEvidence: []string{"Ganzkoerper-Vibrationsmessung nach ISO 2631", "Expositionsbewertung"},
|
||
RelatedKeywords: []string{"Ganzkoerpervibration", "Wirbelsaeule", "Sitzvibrationen"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("noise_vibration", 4),
|
||
Category: "noise_vibration",
|
||
SubCategory: "impulslaerm",
|
||
Name: "Impulslaerm durch Stanz-/Praegevorgaenge",
|
||
Description: "Kurzzeitige Schallspitzen bei Stanz-, Praege- oder Nietvorgaengen ueberschreiten den Spitzenschalldruckpegel und schaedigen das Gehoer besonders stark.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 4,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schalldaemmende Werkzeugeinhausung", "Impulsschallgedaempfter Gehoerschutz"}),
|
||
TypicalCauses: []string{"Metall-auf-Metall-Schlag", "Offene Stanzwerkzeuge", "Fehlende Schalldaemmung"},
|
||
TypicalHarm: "Akutes Knalltrauma, irreversible Gehoerschaedigung",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Elastische Werkzeugauflagen", "Geschlossene Werkzeugkammer"},
|
||
RecommendedMeasuresTechnical: []string{"Schallschutzkabine um Stanzbereich", "Impulslaermueberwachung"},
|
||
RecommendedMeasuresInformation: []string{"Gehoerschutzpflicht-Kennzeichnung", "Schulung zur Impulslaermgefahr"},
|
||
SuggestedEvidence: []string{"Spitzenpegelmessung", "Laermgutachten"},
|
||
RelatedKeywords: []string{"Impulslaerm", "Stanzen", "Spitzenschallpegel"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("noise_vibration", 5),
|
||
Category: "noise_vibration",
|
||
SubCategory: "infraschall",
|
||
Name: "Infraschall von Grossventilatoren",
|
||
Description: "Grosse Ventilatoren und Geblaese erzeugen niederfrequenten Infraschall, der zu Unwohlsein, Konzentrationsstoerungen und Ermuedung fuehren kann.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "actuator"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Schwingungsisolierte Aufstellung", "Schalldaempfer in Kanaelen"}),
|
||
TypicalCauses: []string{"Grosse Ventilatorschaufeln mit niedriger Drehzahl", "Resonanzen in Luftkanaelen", "Fehlende Schwingungsentkopplung"},
|
||
TypicalHarm: "Unwohlsein, Uebelkeit, Konzentrationsstoerungen bei Dauerexposition",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Schwingungsentkopplung des Ventilators", "Resonanzfreie Kanaldimensionierung"},
|
||
RecommendedMeasuresTechnical: []string{"Niederfrequenz-Schalldaempfer", "Infraschall-Messgeraet"},
|
||
RecommendedMeasuresInformation: []string{"Aufklaerung ueber Infraschallsymptome", "Expositionshinweise"},
|
||
SuggestedEvidence: []string{"Infraschallmessung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Infraschall", "Ventilator", "Niederfrequenz"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("noise_vibration", 6),
|
||
Category: "noise_vibration",
|
||
SubCategory: "resonanz",
|
||
Name: "Resonanzschwingungen in Maschinengestell",
|
||
Description: "Anregung des Maschinengestells in seiner Eigenfrequenz kann zu unkontrollierten Schwingungen fuehren, die Bauteile ermueden und zum Versagen bringen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Eigenfrequenzanalyse bei Konstruktion", "Schwingungsdaempfer anbringen"}),
|
||
TypicalCauses: []string{"Drehzahl nahe der Eigenfrequenz des Gestells", "Fehlende Daempfungselemente", "Nachtraegliche Massenveraenderungen"},
|
||
TypicalHarm: "Materialermuedungsbruch mit Absturz von Bauteilen, Verletzungen durch Bruchstuecke",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Eigenfrequenz ausserhalb des Betriebsdrehzahlbereichs legen", "Versteifung des Gestells"},
|
||
RecommendedMeasuresTechnical: []string{"Schwingungssensoren mit Grenzwertueberwachung", "Tilger oder Daempfer anbringen"},
|
||
RecommendedMeasuresInformation: []string{"Verbotene Drehzahlbereiche kennzeichnen", "Schwingungsueberwachungsanleitung"},
|
||
SuggestedEvidence: []string{"Modalanalyse des Gestells", "Schwingungsmessprotokoll"},
|
||
RelatedKeywords: []string{"Resonanz", "Eigenfrequenz", "Strukturschwingung"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
// ====================================================================
|
||
// Category: ergonomic (indices 1-8, 8 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("ergonomic", 1),
|
||
Category: "ergonomic",
|
||
SubCategory: "fehlbedienung",
|
||
Name: "Fehlbedienung durch unguenstige Anordnung von Bedienelementen",
|
||
Description: "Ungluecklich platzierte oder schlecht beschriftete Bedienelemente erhoehen das Risiko von Fehlbedienungen, die sicherheitskritische Maschinenbewegungen ausloesen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"controller", "sensor"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Ergonomische Anordnung nach ISO 9355", "Eindeutige Beschriftung und Farbcodierung"}),
|
||
TypicalCauses: []string{"Nicht-intuitive Anordnung der Schalter", "Fehlende oder unlesbare Beschriftung", "Zu geringer Abstand zwischen Bedienelementen"},
|
||
TypicalHarm: "Verletzungen durch unbeabsichtigte Maschinenaktionen nach Fehlbedienung",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Bedienelemente nach ISO 9355 anordnen", "Farbcodierung und Symbolik nach IEC 60073"},
|
||
RecommendedMeasuresTechnical: []string{"Bestaetigung fuer kritische Aktionen", "Abgedeckte Schalter fuer Gefahrenfunktionen"},
|
||
RecommendedMeasuresInformation: []string{"Bedienerhandbuch mit Bilddarstellungen", "Schulung der Bediener"},
|
||
SuggestedEvidence: []string{"Usability-Test des Bedienfeldes", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Bedienelemente", "Fehlbedienung", "Ergonomie"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("ergonomic", 2),
|
||
Category: "ergonomic",
|
||
SubCategory: "zwangshaltung",
|
||
Name: "Zwangshaltung bei Beschickungsvorgaengen",
|
||
Description: "Unglueckliche Koerperhaltungen beim manuellen Beladen oder Entnehmen von Werkstuecken fuehren zu muskuloskeletalen Beschwerden.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Hoehenverstellbare Beschickungsoeffnung", "Automatische Materialzufuhr"}),
|
||
TypicalCauses: []string{"Beschickungsoeffnung in unguenstiger Hoehe", "Grosse Greifentfernung", "Wiederholte Drehbewegungen des Rumpfes"},
|
||
TypicalHarm: "Rueckenbeschwerden, Schulter-Arm-Syndrom, chronische Gelenkschmerzen",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Beschickungshoehe zwischen 60 und 120 cm", "Kurze Greifwege"},
|
||
RecommendedMeasuresTechnical: []string{"Hoehenverstellbare Arbeitstische", "Hebehilfen und Manipulatoren"},
|
||
RecommendedMeasuresInformation: []string{"Ergonomie-Schulung", "Hinweise zur richtigen Koerperhaltung"},
|
||
SuggestedEvidence: []string{"Ergonomische Arbeitsplatzanalyse", "Gefaehrdungsbeurteilung"},
|
||
RelatedKeywords: []string{"Zwangshaltung", "Beschickung", "Muskel-Skelett"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("ergonomic", 3),
|
||
Category: "ergonomic",
|
||
SubCategory: "manuelle_handhabung",
|
||
Name: "Koerperliche Ueberforderung durch manuelle Handhabung",
|
||
Description: "Schwere Lasten muessen manuell gehoben, getragen oder verschoben werden, was zu akuten Verletzungen oder chronischen Schaeden fuehrt.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 4,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Technische Hebehilfen bereitstellen", "Gewichtsgrenze fuer manuelles Heben festlegen"}),
|
||
TypicalCauses: []string{"Fehlende Hebehilfen", "Zu schwere Einzelteile", "Haeufiges Heben ueber Schulterhoehe"},
|
||
TypicalHarm: "Bandscheibenvorfall, Rueckenverletzungen, Ueberanstrengung",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Bauteile unter 15 kg fuer manuelles Handling", "Hebevorrichtungen integrieren"},
|
||
RecommendedMeasuresTechnical: []string{"Kran oder Hebezeug am Arbeitsplatz", "Vakuumheber fuer Platten"},
|
||
RecommendedMeasuresInformation: []string{"Hebebelastungstabelle aushangen", "Unterweisung in Hebetechnik"},
|
||
SuggestedEvidence: []string{"Lastenhandhabungsbeurteilung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Heben", "Lastenhandhabung", "Ueberanstrengung"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("ergonomic", 4),
|
||
Category: "ergonomic",
|
||
SubCategory: "verwechslung",
|
||
Name: "Verwechslungsgefahr bei gleichartigen Bedienelementen",
|
||
Description: "Baugleiche, nicht unterscheidbare Taster oder Schalter koennen verwechselt werden, was zu unbeabsichtigten und gefaehrlichen Maschinenaktionen fuehrt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 4,
|
||
ApplicableComponentTypes: []string{"controller", "sensor"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Unterschiedliche Formen und Farben fuer verschiedene Funktionen", "Beschriftung in Klartext"}),
|
||
TypicalCauses: []string{"Identische Tasterform fuer unterschiedliche Funktionen", "Fehlende Beschriftung", "Schlechte Beleuchtung am Bedienfeld"},
|
||
TypicalHarm: "Unbeabsichtigte Maschinenaktionen mit Verletzungsgefahr",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Form- und Farbcodierung nach IEC 60073", "Raeumliche Gruppierung nach Funktionsbereichen"},
|
||
RecommendedMeasuresTechnical: []string{"Beleuchtetes Bedienfeld", "Haptisch unterscheidbare Taster"},
|
||
RecommendedMeasuresInformation: []string{"Bedienfeldplan am Arbeitsplatz aushangen", "Einweisung neuer Bediener"},
|
||
SuggestedEvidence: []string{"Usability-Bewertung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Verwechslung", "Taster", "Bedienpanel"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("ergonomic", 5),
|
||
Category: "ergonomic",
|
||
SubCategory: "sichtbehinderung",
|
||
Name: "Sichtbehinderung des Gefahrenbereichs vom Bedienplatz",
|
||
Description: "Vom Bedienplatz aus ist der Gefahrenbereich nicht vollstaendig einsehbar, sodass der Bediener Personen im Gefahrenbereich nicht erkennen kann.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"controller", "sensor", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Kameraueberwachung des Gefahrenbereichs", "Sicherheits-Laserscanner"}),
|
||
TypicalCauses: []string{"Verdeckte Sicht durch Maschinenteile", "Bedienplatz zu weit vom Arbeitsbereich", "Fehlende Spiegel oder Kameras"},
|
||
TypicalHarm: "Schwere Verletzungen von Personen im nicht einsehbaren Gefahrenbereich",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "setup"},
|
||
RecommendedMeasuresDesign: []string{"Bedienplatz mit direkter Sicht auf Gefahrenbereich", "Transparente Schutzeinrichtungen"},
|
||
RecommendedMeasuresTechnical: []string{"Kamerasystem mit Monitor am Bedienplatz", "Sicherheits-Laserscanner"},
|
||
RecommendedMeasuresInformation: []string{"Hinweis auf toten Winkel", "Anlaufwarnung vor Maschinenbewegung"},
|
||
SuggestedEvidence: []string{"Sichtfeldanalyse vom Bedienplatz", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Sichtfeld", "Toter Winkel", "Bedienplatz"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("ergonomic", 6),
|
||
Category: "ergonomic",
|
||
SubCategory: "griffgestaltung",
|
||
Name: "Unergonomische Griffgestaltung von Handwerkzeugen",
|
||
Description: "Schlecht geformte Griffe an handgefuehrten Werkzeugen und Hebeln fuehren zu Ermuedung, verminderter Griffkraft und erhoehtem Unfallrisiko.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 4,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Ergonomische Griffformen nach EN 894", "Rutschfeste Griffoberflaechen"}),
|
||
TypicalCauses: []string{"Zu duenner oder zu dicker Griff", "Glatte Griffoberflaeche", "Scharfe Kanten am Griff"},
|
||
TypicalHarm: "Sehnenscheidenentzuendung, Abrutschen mit Folgeverletzung",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Griffdurchmesser 30-45 mm", "Anatomisch geformte Griffe"},
|
||
RecommendedMeasuresTechnical: []string{"Rutschfeste Beschichtung", "Handgelenkschlaufe an Handwerkzeugen"},
|
||
RecommendedMeasuresInformation: []string{"Auswahl ergonomischer Werkzeuge dokumentieren", "Arbeitsmedizinische Beratung"},
|
||
SuggestedEvidence: []string{"Ergonomische Werkzeugbewertung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Griff", "Handwerkzeug", "Ergonomie"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("ergonomic", 7),
|
||
Category: "ergonomic",
|
||
SubCategory: "monotonie",
|
||
Name: "Monotone Taetigkeit fuehrt zu Aufmerksamkeitsverlust",
|
||
Description: "Langandauernde, sich wiederholende Taetigkeiten ohne Abwechslung vermindern die Aufmerksamkeit des Bedieners und erhoehen die Unfallgefahr.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Aufgabenwechsel organisieren", "Regelmaessige Pausen einplanen"}),
|
||
TypicalCauses: []string{"Gleichfoermige Wiederholtaetigkeit", "Fehlende Pausenregelung", "Mangelnde Aufgabenvielfalt"},
|
||
TypicalHarm: "Unfaelle durch Unaufmerksamkeit, verspaetete Reaktion auf Gefahren",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Automatisierung monotoner Teilaufgaben", "Arbeitsplatzrotation ermoeglichen"},
|
||
RecommendedMeasuresTechnical: []string{"Aufmerksamkeitserkennung", "Regelmaessige Warnmeldungen"},
|
||
RecommendedMeasuresInformation: []string{"Pausenplan erstellen", "Schulung zur Ermuedungserkennung"},
|
||
SuggestedEvidence: []string{"Arbeitsplatzanalyse", "Gefaehrdungsbeurteilung psychische Belastung"},
|
||
RelatedKeywords: []string{"Monotonie", "Aufmerksamkeit", "Ermuedung"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("ergonomic", 8),
|
||
Category: "ergonomic",
|
||
SubCategory: "wartungszugang",
|
||
Name: "Ungenuegender Zugang fuer Wartungsarbeiten",
|
||
Description: "Enge oder schwer zugaengliche Wartungsbereiche zwingen das Personal zu gefaehrlichen Koerperhaltungen und erhoehen das Risiko von Verletzungen.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Wartungsoeffnungen ausreichend dimensionieren", "Wartungsbuehnen und Podeste vorsehen"}),
|
||
TypicalCauses: []string{"Zu kleine Wartungsoeffnungen", "Fehlende Arbeitsbuehnen in der Hoehe", "Wartungspunkte hinter schwer zu demontierenden Verkleidungen"},
|
||
TypicalHarm: "Quetschungen in engen Raeumen, Absturz von erhoehten Wartungspositionen",
|
||
RelevantLifecyclePhases: []string{"maintenance", "fault_finding"},
|
||
RecommendedMeasuresDesign: []string{"Mindestmasse fuer Zugangsoeeffnungen nach ISO 14122", "Wartungspunkte leicht zugaenglich anordnen"},
|
||
RecommendedMeasuresTechnical: []string{"Feste Buehnen und Leitern mit Absturzsicherung", "Schnellverschluesse statt Schraubverbindungen an Wartungsklappen"},
|
||
RecommendedMeasuresInformation: []string{"Wartungszugangsskizze in Betriebsanleitung", "Hinweis auf PSA-Pflicht bei Arbeiten in der Hoehe"},
|
||
SuggestedEvidence: []string{"Zugaenglichkeitspruefung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Wartungszugang", "Zugaenglichkeit", "Wartungsbuehne"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
// ====================================================================
|
||
// Category: material_environmental (indices 1-8, 8 entries)
|
||
// ====================================================================
|
||
{
|
||
ID: hazardUUID("material_environmental", 1),
|
||
Category: "material_environmental",
|
||
SubCategory: "staubexplosion",
|
||
Name: "Staubexplosion durch Feinpartikel",
|
||
Description: "Feine brennbare Staube koennen in Verbindung mit einer Zuendquelle explosionsartig reagieren und schwere Zerstoerungen verursachen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 2,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"ATEX-konforme Ausfuehrung", "Absauganlage mit Funkenerkennung"}),
|
||
TypicalCauses: []string{"Unzureichende Absaugung", "Staubansammlung in Hohlraeumen", "Elektrische oder mechanische Zuendquelle"},
|
||
TypicalHarm: "Explosion mit toedlichen Verletzungen, schwere Verbrennungen, Gebaeudezerstoerung",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "cleaning"},
|
||
RecommendedMeasuresDesign: []string{"ATEX-konforme Konstruktion", "Druckentlastungsflaechen vorsehen"},
|
||
RecommendedMeasuresTechnical: []string{"Absaugung mit Funkenloeschanlage", "Explosionsunterdrueckung"},
|
||
RecommendedMeasuresInformation: []string{"Ex-Zoneneinteilung kennzeichnen", "Reinigungsplan fuer Staubablagerungen"},
|
||
SuggestedEvidence: []string{"Explosionsschutz-Dokument", "ATEX-Konformitaetserklaerung"},
|
||
RelatedKeywords: []string{"Staubexplosion", "ATEX", "Feinstaub"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("material_environmental", 2),
|
||
Category: "material_environmental",
|
||
SubCategory: "rauch_gas",
|
||
Name: "Rauch- und Gasfreisetzung bei Laserschneiden",
|
||
Description: "Beim Laserschneiden entstehen gesundheitsschaedliche Rauche und Gase aus dem verdampften Material, die die Atemwege schaedigen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 4,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Absaugung direkt am Bearbeitungspunkt", "Filteranlage mit Aktivkohlestufe"}),
|
||
TypicalCauses: []string{"Fehlende Absaugung", "Verarbeitung kunststoffbeschichteter Materialien", "Undichte Maschineneinhausung"},
|
||
TypicalHarm: "Atemwegserkrankungen, Reizung von Augen und Schleimhaeuten",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Geschlossener Bearbeitungsraum mit Absaugung", "Materialauswahl ohne toxische Beschichtungen"},
|
||
RecommendedMeasuresTechnical: []string{"Punktabsaugung mit HEPA-Filter", "Raumluft-Monitoring"},
|
||
RecommendedMeasuresInformation: []string{"Materialfreigabeliste pflegen", "Atemschutz-PSA bei Sondermaterialien"},
|
||
SuggestedEvidence: []string{"Arbeitsplatzmessung Gefahrstoffe", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"Laserschneiden", "Rauch", "Gefahrstoff"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("material_environmental", 3),
|
||
Category: "material_environmental",
|
||
SubCategory: "kuehlschmierstoff",
|
||
Name: "Daempfe aus Kuehlschmierstoffen",
|
||
Description: "Beim Einsatz von Kuehlschmierstoffen entstehen Aerosole und Daempfe, die bei Langzeitexposition zu Haut- und Atemwegserkrankungen fuehren.",
|
||
DefaultSeverity: 3,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 4,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Oelunebelabscheider an der Maschine", "Hautschutzplan fuer Bediener"}),
|
||
TypicalCauses: []string{"Offene Bearbeitungszonen ohne Abschirmung", "Ueberaltertes Kuehlschmiermittel", "Zu hoher Kuehlmitteldurchsatz"},
|
||
TypicalHarm: "Oelakne, Atemwegssensibilisierung, allergische Hautreaktionen",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Geschlossener Bearbeitungsraum", "Minimalmengenschmierung statt Volumenoelstrom"},
|
||
RecommendedMeasuresTechnical: []string{"Oelunebelabscheider", "KSS-Konzentrations- und pH-Ueberwachung"},
|
||
RecommendedMeasuresInformation: []string{"Hautschutz- und Hygieneplan", "KSS-Pflegeanweisung"},
|
||
SuggestedEvidence: []string{"Arbeitsplatz-Gefahrstoffmessung", "Hautschutzplan"},
|
||
RelatedKeywords: []string{"Kuehlschmierstoff", "KSS", "Aerosol"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("material_environmental", 4),
|
||
Category: "material_environmental",
|
||
SubCategory: "prozessmedien",
|
||
Name: "Chemische Exposition durch Prozessmedien",
|
||
Description: "Chemisch aggressive Prozessmedien wie Saeuren, Laugen oder Loesemittel koennen bei Hautkontakt oder Einatmen schwere Gesundheitsschaeden verursachen.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"other", "mechanical"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Geschlossene Mediumfuehrung", "Chemikalienschutz-PSA"}),
|
||
TypicalCauses: []string{"Offene Behaelter mit Gefahrstoffen", "Spritzer beim Nachfuellen", "Leckage an Dichtungen"},
|
||
TypicalHarm: "Veraetzungen, Atemwegsschaedigung, Vergiftung",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance", "cleaning"},
|
||
RecommendedMeasuresDesign: []string{"Geschlossene Kreislaeufe", "Korrosionsbestaendige Materialien"},
|
||
RecommendedMeasuresTechnical: []string{"Notdusche und Augenspueler", "Gaswarnanlage"},
|
||
RecommendedMeasuresInformation: []string{"Sicherheitsdatenblaetter am Arbeitsplatz", "Gefahrstoffunterweisung"},
|
||
SuggestedEvidence: []string{"Gefahrstoffverzeichnis", "Arbeitsplatzmessung"},
|
||
RelatedKeywords: []string{"Gefahrstoff", "Chemikalie", "Prozessmedium"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("material_environmental", 5),
|
||
Category: "material_environmental",
|
||
SubCategory: "dichtungsversagen",
|
||
Name: "Leckage von Gefahrstoffen bei Dichtungsversagen",
|
||
Description: "Versagende Dichtungen an Rohrleitungen oder Behaeltern setzen Gefahrstoffe frei und gefaehrden Personal und Umwelt.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Doppelwandige Behaelter mit Leckagedetektion", "Auffangwannen unter allen Gefahrstoffbereichen"}),
|
||
TypicalCauses: []string{"Alterung der Dichtungsmaterialien", "Chemische Unvertraeglichkeit", "Thermische Ueberbelastung der Dichtung"},
|
||
TypicalHarm: "Gefahrstofffreisetzung mit Vergiftung, Hautschaedigung, Umweltschaden",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Doppelwandige Leitungen", "Chemisch bestaendige Dichtungswerkstoffe"},
|
||
RecommendedMeasuresTechnical: []string{"Leckagesensoren", "Auffangwannen mit Fassungsvermoegen 110%"},
|
||
RecommendedMeasuresInformation: []string{"Dichtungswechselintervalle festlegen", "Notfallplan Gefahrstoffaustritt"},
|
||
SuggestedEvidence: []string{"Dichtheitspruefprotokoll", "Gefahrstoff-Notfallplan"},
|
||
RelatedKeywords: []string{"Leckage", "Dichtung", "Gefahrstoff"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("material_environmental", 6),
|
||
Category: "material_environmental",
|
||
SubCategory: "biologische_kontamination",
|
||
Name: "Biologische Kontamination in Lebensmittelmaschinen",
|
||
Description: "In Maschinen der Lebensmittelindustrie koennen sich Mikroorganismen in schwer zu reinigenden Bereichen ansiedeln und das Produkt kontaminieren.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Hygienic-Design-Konstruktion", "CIP-Reinigungssystem"}),
|
||
TypicalCauses: []string{"Totraeume und Hinterschneidungen in der Konstruktion", "Unzureichende Reinigung", "Poroese Oberflaechen"},
|
||
TypicalHarm: "Lebensmittelkontamination mit Gesundheitsgefaehrdung der Verbraucher",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "cleaning", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Hygienic Design nach EHEDG-Richtlinien", "Selbstentleerende Konstruktion"},
|
||
RecommendedMeasuresTechnical: []string{"CIP-Reinigungsanlage", "Oberflaechenguete Ra kleiner 0.8 Mikrometer"},
|
||
RecommendedMeasuresInformation: []string{"Reinigungs- und Desinfektionsplan", "Hygieneschulung des Personals"},
|
||
SuggestedEvidence: []string{"EHEDG-Zertifikat", "Mikrobiologische Abklatschproben"},
|
||
RelatedKeywords: []string{"Hygiene", "Kontamination", "Lebensmittelsicherheit"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("material_environmental", 7),
|
||
Category: "material_environmental",
|
||
SubCategory: "elektrostatik",
|
||
Name: "Statische Aufladung in staubhaltiger Umgebung",
|
||
Description: "In staubhaltiger oder explosionsfaehiger Atmosphaere kann eine elektrostatische Entladung als Zuendquelle wirken und eine Explosion oder einen Brand ausloesen.",
|
||
DefaultSeverity: 5,
|
||
DefaultProbability: 2,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "electrical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Erdung aller leitfaehigen Teile", "Ableitfaehige Bodenbeschichtung"}),
|
||
TypicalCauses: []string{"Nicht geerdete Maschinenteile", "Reibung von Kunststoffbaendern", "Niedrige Luftfeuchtigkeit"},
|
||
TypicalHarm: "Zuendung explosionsfaehiger Atmosphaere, Explosion oder Brand",
|
||
RelevantLifecyclePhases: []string{"normal_operation"},
|
||
RecommendedMeasuresDesign: []string{"Leitfaehige Materialien verwenden", "Erdungskonzept fuer alle Komponenten"},
|
||
RecommendedMeasuresTechnical: []string{"Ionisatoren zur Ladungsneutralisation", "Erdungsueberwachung"},
|
||
RecommendedMeasuresInformation: []string{"ESD-Hinweisschilder", "Schulung zur elektrostatischen Gefaehrdung"},
|
||
SuggestedEvidence: []string{"Erdungsmessung", "Explosionsschutz-Dokument"},
|
||
RelatedKeywords: []string{"Elektrostatik", "ESD", "Zuendquelle"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
{
|
||
ID: hazardUUID("material_environmental", 8),
|
||
Category: "material_environmental",
|
||
SubCategory: "uv_strahlung",
|
||
Name: "UV-Strahlung bei Schweiss- oder Haerteprozessen",
|
||
Description: "Schweissvorgaenge und UV-Haerteprozesse emittieren ultraviolette Strahlung, die Augen und Haut schwer schaedigen kann.",
|
||
DefaultSeverity: 4,
|
||
DefaultProbability: 3,
|
||
DefaultExposure: 3,
|
||
DefaultAvoidance: 3,
|
||
ApplicableComponentTypes: []string{"mechanical", "electrical", "other"},
|
||
RegulationReferences: []string{"Maschinenverordnung 2023/1230 Anhang I"},
|
||
SuggestedMitigations: mustMarshalJSON([]string{"Abschirmung des UV-Bereichs", "Schweissschutzschirm und Schutzkleidung"}),
|
||
TypicalCauses: []string{"Fehlende Abschirmung der UV-Quelle", "Reflexion an glaenzenden Oberflaechen", "Aufenthalt im Strahlungsbereich ohne Schutz"},
|
||
TypicalHarm: "Verblitzen der Augen, Hautverbrennungen, erhoehtes Hautkrebsrisiko bei Langzeitexposition",
|
||
RelevantLifecyclePhases: []string{"normal_operation", "maintenance"},
|
||
RecommendedMeasuresDesign: []string{"Vollstaendige Einhausung der UV-Quelle", "UV-absorbierende Schutzscheiben"},
|
||
RecommendedMeasuresTechnical: []string{"Schweissvorhaenge um den Arbeitsbereich", "UV-Sensor mit Abschaltung"},
|
||
RecommendedMeasuresInformation: []string{"Warnhinweis UV-Strahlung", "PSA-Pflicht: Schweissschutzhelm und Schutzkleidung"},
|
||
SuggestedEvidence: []string{"UV-Strahlungsmessung", "Risikobeurteilung"},
|
||
RelatedKeywords: []string{"UV-Strahlung", "Schweissen", "Strahlenschutz"},
|
||
IsBuiltin: true,
|
||
TenantID: nil,
|
||
CreatedAt: now,
|
||
},
|
||
}
|
||
|
||
entries = append(entries, iso12100Entries...)
|
||
|
||
return entries
|
||
}
|