package iace // GetFinalPatternsB returns 85 electrical, thermal, chemical, biological, // radiation, noise, and asphyxiation hazard patterns (HP1085-HP1169). func GetFinalPatternsB() []HazardPattern { return []HazardPattern{ // === Elektrisch Beruehrung (5) === { ID: "HP1085", NameDE: "Direktes Beruehren spannungsfuehrender Teile", NameEN: "Direct contact with live parts", RequiredComponentTags: []string{"electrical_part"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003", "M054"}, SuggestedEvidenceIDs: []string{"E01", "E06", "E08"}, Priority: 85, ScenarioDE: "Person beruehrt aktive Leiter bei offener Abdeckung", TriggerDE: "Wartung ohne Freischalten, defekte Isolation", HarmDE: "Stromschlag, Herzrhythmusstoerung", AffectedDE: "Elektrofachkraft, Wartungspersonal", ZoneDE: "Schaltschrank, Klemmenraum", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1086", NameDE: "Indirektes Beruehren bei Koerperschluss", NameEN: "Indirect contact via fault current", RequiredComponentTags: []string{"electrical_part", "structural_part"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003"}, SuggestedEvidenceIDs: []string{"E01", "E06"}, Priority: 80, ScenarioDE: "Maschinengehaeuse fuehrt Spannung bei Isolationsfehler", TriggerDE: "Isolationsversagen, fehlender Schutzleiter", HarmDE: "Stromschlag durch Gehaeuse", AffectedDE: "Bedienpersonal", ZoneDE: "Maschinengehaeuse, Metallteile", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1087", NameDE: "Lichtbogen bei Kurzschluss", NameEN: "Arc flash at short circuit", RequiredComponentTags: []string{"electrical_part", "high_temperature"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard", "thermal_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003", "M054", "M141"}, SuggestedEvidenceIDs: []string{"E01", "E06", "E08"}, Priority: 85, ScenarioDE: "Lichtbogen entsteht bei Kurzschluss im Schaltschrank", TriggerDE: "Werkzeug verursacht Kurzschluss, Feuchte", HarmDE: "Schwere Verbrennung, Augenschaden", AffectedDE: "Elektrofachkraft", ZoneDE: "Schaltschrank, Sammelschiene", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1088", NameDE: "Kriechstrom ueber feuchte Oberflaeche", NameEN: "Leakage current via wet surface", RequiredComponentTags: []string{"electrical_part", "structural_part"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003"}, SuggestedEvidenceIDs: []string{"E01", "E06"}, Priority: 72, ScenarioDE: "Kriechstrom fliesst ueber nasse Maschinenflaeche", TriggerDE: "Reinigung mit Wasser, Kondensation, Leckage", HarmDE: "Stromschlag, Muskelverkrampfung", AffectedDE: "Reinigungspersonal, Bediener", ZoneDE: "Feuchte Oberflaechen, Boden", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1089", NameDE: "Elektrostatische Entladung", NameEN: "Electrostatic discharge", RequiredComponentTags: []string{"electrical_part"}, RequiredEnergyTags: []string{"electrical"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M001"}, SuggestedEvidenceIDs: []string{"E01"}, Priority: 55, ScenarioDE: "Elektrostatische Entladung zuendet Atmosphaere", TriggerDE: "Statische Aufladung bei Schuettgut/Folie, Funke", HarmDE: "Brand, leichte Verbrennung", AffectedDE: "Bedienpersonal", ZoneDE: "Schuettgutbehaelter, Folienanlage", DefaultSeverity: 3, DefaultExposure: 2, }, // === Elektrisch Kurzschluss (3) === { ID: "HP1090", NameDE: "Kurzschluss beschaedigtes Kabel", NameEN: "Short circuit damaged cable", RequiredComponentTags: []string{"electrical_part", "moving_part"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003"}, SuggestedEvidenceIDs: []string{"E01", "E06"}, Priority: 75, ScenarioDE: "Kabelisolierung durch Scheuern oder Quetschung beschaedigt", TriggerDE: "Kabel in Bewegungsbereich, scharfe Kante", HarmDE: "Brand, Stromschlag", AffectedDE: "Bedienpersonal", ZoneDE: "Kabelfuehrung, Schleppkette", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1091", NameDE: "Kurzschluss an lockerer Klemme", NameEN: "Short circuit at loose terminal", RequiredComponentTags: []string{"electrical_part"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard", "thermal_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003"}, SuggestedEvidenceIDs: []string{"E01", "E06"}, Priority: 70, ScenarioDE: "Lockere Klemme verursacht Lichtbogen und Brand", TriggerDE: "Vibration lockert Klemme, Oxidation", HarmDE: "Schaltschrankbrand", AffectedDE: "Umgebungspersonen", ZoneDE: "Schaltschrank, Klemmenleiste", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1092", NameDE: "Kurzschluss durch Feuchtigkeit", NameEN: "Short circuit by moisture", RequiredComponentTags: []string{"electrical_part", "structural_part"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003"}, SuggestedEvidenceIDs: []string{"E01", "E06"}, Priority: 72, ScenarioDE: "Wasser dringt in elektrische Komponente ein", TriggerDE: "Undichte Kabeldurchfuehrung, Ueberflutung", HarmDE: "Kurzschluss, Brand", AffectedDE: "Bedienpersonal", ZoneDE: "Steckverbindungen, Kabelenden", DefaultSeverity: 4, DefaultExposure: 2, }, // === Elektrisch Ueberlast (3) === { ID: "HP1093", NameDE: "Motorueberlast mit Ueberhitzung", NameEN: "Motor overload with overheating", RequiredComponentTags: []string{"electrical_part", "high_temperature"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard", "thermal_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003"}, SuggestedEvidenceIDs: []string{"E01", "E06"}, Priority: 72, ScenarioDE: "Motor ueberhitzt durch dauerhaften Ueberlastbetrieb", TriggerDE: "Zu hohe Last, blockierter Antrieb, fehlender Schutz", HarmDE: "Wicklungsbrand, Rauchentwicklung", AffectedDE: "Bedienpersonal", ZoneDE: "Motorgehaeuse, Umgebung", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1094", NameDE: "Leitungsueberlast mit Kabelbrand", NameEN: "Cable overload with fire", RequiredComponentTags: []string{"electrical_part"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard", "thermal_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003"}, SuggestedEvidenceIDs: []string{"E01", "E06"}, Priority: 75, ScenarioDE: "Zu duenner Kabelquerschnitt fuehrt zu Kabelbrand", TriggerDE: "Falsche Dimensionierung, fehlende Sicherung", HarmDE: "Kabelbrand, Brandausbreitung", AffectedDE: "Umgebungspersonen", ZoneDE: "Kabelkanal, Leitungsfuehrung", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1095", NameDE: "Schaltschrankueberhitzung", NameEN: "Switchgear overheating", RequiredComponentTags: []string{"electrical_part", "high_temperature"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"electrical_hazard", "thermal_hazard"}, SuggestedMeasureIDs: []string{"M001", "M003"}, SuggestedEvidenceIDs: []string{"E01", "E06"}, Priority: 70, ScenarioDE: "Schaltschrank ueberhitzt durch defekte Kuehlung", TriggerDE: "Luefter defekt, Filter verstopft, Ueberbelegung", HarmDE: "Komponentenausfall, Brand", AffectedDE: "Elektrofachkraft", ZoneDE: "Schaltschrank, Kuehloeffnungen", DefaultSeverity: 3, DefaultExposure: 2, }, // === Thermisch Verbrennung (5) === { ID: "HP1096", NameDE: "Verbrennung an heisser Oberflaeche", NameEN: "Burn on hot surface", RequiredComponentTags: []string{"high_temperature", "structural_part"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 72, ScenarioDE: "Beruehrung heisser ungeschuetzter Oberflaeche", TriggerDE: "Fehlende Isolation, fehlende Warnung", HarmDE: "Kontaktverbrennung 2. Grades", AffectedDE: "Bedienpersonal", ZoneDE: "Heizflaeche, Rohrleitung", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1097", NameDE: "Verbruehung durch Dampfaustritt", NameEN: "Scald by steam release", RequiredComponentTags: []string{"high_temperature", "high_pressure"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M051", "M054", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 78, ScenarioDE: "Heisser Dampf tritt unkontrolliert aus", TriggerDE: "Dichtungsversagen, Ventildefekt, Ueberkochen", HarmDE: "Verbruehung Gesicht/Haende", AffectedDE: "Bedienpersonal", ZoneDE: "Dampfleitung, Ventilauslass", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1098", NameDE: "Verbrennung durch offene Flamme", NameEN: "Burn by open flame", RequiredComponentTags: []string{"high_temperature"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 80, ScenarioDE: "Kontakt mit Flamme bei Brenn- oder Loetarbeiten", TriggerDE: "Unkontrollierte Flamme, Rueckzuendung", HarmDE: "Verbrennung 2.-3. Grades", AffectedDE: "Schweisser, Bedienpersonal", ZoneDE: "Brennerbereich, Flammenzone", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1099", NameDE: "Verbrennung durch Metallschmelze", NameEN: "Burn by molten metal", RequiredComponentTags: []string{"high_temperature", "chemical_risk"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 85, ScenarioDE: "Spritzer von geschmolzenem Metall treffen Haut", TriggerDE: "Wasser auf Schmelze, Giessfehler", HarmDE: "Schwere Verbrennung, Gewebszerstoerung", AffectedDE: "Giesser, Schweisser", ZoneDE: "Giessbereich, Schmelzofen", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1100", NameDE: "Verbrennung durch Schweissspritzer", NameEN: "Burn by welding spatter", RequiredComponentTags: []string{"high_temperature"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 68, ScenarioDE: "Gluehende Schweissspritzer treffen ungeschuetzte Haut", TriggerDE: "Fehlende Schuerze, offene Aermel", HarmDE: "Punktverbrennung, Kleidungsbrand", AffectedDE: "Schweisser, Nachbarpersonal", ZoneDE: "Schweissplatz, Umgebung", DefaultSeverity: 3, DefaultExposure: 3, }, // === Thermisch Erfrierung (3) === { ID: "HP1101", NameDE: "Erfrierung durch Kaeltemittelaustritt", NameEN: "Frostbite by refrigerant leak", RequiredComponentTags: []string{"high_pressure", "chemical_risk"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard", "material_environmental"}, SuggestedMeasureIDs: []string{"M051", "M054", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 72, ScenarioDE: "Kaeltemittel tritt aus und gefriert auf Haut", TriggerDE: "Leitungsleck, Ventilversagen", HarmDE: "Lokale Erfrierung, Gewebsnekrose", AffectedDE: "Wartungspersonal", ZoneDE: "Kaelteanlage, Verbindungsstellen", DefaultSeverity: 3, DefaultExposure: 2, }, { ID: "HP1102", NameDE: "Erfrierung Kryogen-Kontakt", NameEN: "Frostbite cryogenic contact", RequiredComponentTags: []string{"chemical_risk", "high_pressure"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard", "material_environmental"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 78, ScenarioDE: "Kontakt mit kryogener Fluessigkeit (LN2, CO2)", TriggerDE: "Verschuetten, defekter Behaelter, fehlende PSA", HarmDE: "Schwere Erfrierung, Gewebstod", AffectedDE: "Laborpersonal, Bediener", ZoneDE: "Kryobehaelter, Fuellanschluss", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1103", NameDE: "Unterkuehlung Winterarbeit im Freien", NameEN: "Hypothermia outdoor winter work", RequiredComponentTags: []string{"structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"thermal_hazard", "ergonomic"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E01"}, Priority: 55, ScenarioDE: "Person unterkuehlt bei Arbeit im Freien im Winter", TriggerDE: "Lange Exposition, nasse Kleidung, Wind", HarmDE: "Unterkuehlung, Erfrierung", AffectedDE: "Aussenpersonal, Monteure", ZoneDE: "Freigelände, Baustelle", DefaultSeverity: 3, DefaultExposure: 3, }, // === Thermisch Waermestrahlung (3) === { ID: "HP1104", NameDE: "Waermestrahlung vom Ofen", NameEN: "Heat radiation from furnace", RequiredComponentTags: []string{"high_temperature", "structural_part"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 68, ScenarioDE: "Intensive Waermestrahlung vom geoeffneten Ofen", TriggerDE: "Ofentuer offen, fehlender Strahlungsschutz", HarmDE: "Hitzschlag, Hautverbrennung", AffectedDE: "Ofenpersonal", ZoneDE: "Vor dem Ofen, Beschickungsbereich", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1105", NameDE: "Waermestrahlung Schmelztiegel", NameEN: "Heat radiation from crucible", RequiredComponentTags: []string{"high_temperature", "chemical_risk"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 72, ScenarioDE: "Waermestrahlung von offenem Schmelztiegel", TriggerDE: "Fehlender Abstand, kein Visier", HarmDE: "Gesichtsverbrennung, Dehydrierung", AffectedDE: "Giesser", ZoneDE: "Schmelztiegelbereich", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1106", NameDE: "Waermestrahlung Infrarottrockner", NameEN: "Heat radiation infrared dryer", RequiredComponentTags: []string{"high_temperature", "radiation_risk"}, RequiredEnergyTags: []string{"thermal", "radiation"}, GeneratedHazardCats: []string{"thermal_hazard", "radiation_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 65, ScenarioDE: "IR-Strahler verursacht Verbrennung bei Annaeherung", TriggerDE: "Fehlende Abschirmung, Aufenthalt im Strahlfeld", HarmDE: "Hautverbrennung", AffectedDE: "Bedienpersonal", ZoneDE: "Trocknerzone, Strahlerfront", DefaultSeverity: 3, DefaultExposure: 3, }, // === Chemisch Einatmen (8) === { ID: "HP1107", NameDE: "Einatmen Loesemitteldampf", NameEN: "Inhalation solvent vapour", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 72, ScenarioDE: "Loesemitteldaempfe werden eingeatmet", TriggerDE: "Offene Behaelter, fehlende Absaugung", HarmDE: "Schwindel, Bewusstlosigkeit", AffectedDE: "Bedienpersonal, Reinigungspersonal", ZoneDE: "Lackierbereich, Reinigungsplatz", DefaultSeverity: 3, DefaultExposure: 4, }, { ID: "HP1108", NameDE: "Einatmen Schweissrauch", NameEN: "Inhalation welding fume", RequiredComponentTags: []string{"high_temperature", "chemical_risk"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 75, ScenarioDE: "Schweissrauch wird beim Schweissen eingeatmet", TriggerDE: "Fehlende Absaugung, enger Raum", HarmDE: "Metalldampffieber, Lungenschaden", AffectedDE: "Schweisser, Nachbarpersonal", ZoneDE: "Schweissplatz, geschlossener Raum", DefaultSeverity: 3, DefaultExposure: 4, }, { ID: "HP1109", NameDE: "Einatmen Metallstaub", NameEN: "Inhalation metal dust", RequiredComponentTags: []string{"chemical_risk", "cutting_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Metallstaub aus Schleif-/Trennarbeiten eingeatmet", TriggerDE: "Trockenschliff, fehlende Absaugung", HarmDE: "Pneumokoniose, Lungenkrebs", AffectedDE: "Schleifer, Bedienpersonal", ZoneDE: "Schleifplatz, Umgebung", DefaultSeverity: 4, DefaultExposure: 4, }, { ID: "HP1110", NameDE: "Einatmen Holzstaub", NameEN: "Inhalation wood dust", RequiredComponentTags: []string{"chemical_risk", "cutting_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Holzstaub wird bei Saege-/Schleifarbeiten eingeatmet", TriggerDE: "Fehlende Absaugung, offene Bearbeitung", HarmDE: "Nasenkrebs (Hartholz), Asthma", AffectedDE: "Tischler, Bedienpersonal", ZoneDE: "Holzbearbeitungsplatz", DefaultSeverity: 4, DefaultExposure: 4, }, { ID: "HP1111", NameDE: "Einatmen Mehlstaub", NameEN: "Inhalation flour dust", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Mehlstaub in der Luft beim Schuetten/Mischen", TriggerDE: "Offener Umschlag, fehlende Kapselung", HarmDE: "Baeckerasthma, Explosionsgefahr", AffectedDE: "Bedienpersonal", ZoneDE: "Schuettstelle, Mischer", DefaultSeverity: 3, DefaultExposure: 4, }, { ID: "HP1112", NameDE: "Einatmen Saeuredampf", NameEN: "Inhalation acid vapour", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 78, ScenarioDE: "Saeuredampf wird beim Umfuellen oder Erwaermen frei", TriggerDE: "Offener Behaelter, Erwaermung, Verschuetten", HarmDE: "Veraetzung Atemwege, Lungenoedem", AffectedDE: "Bedienpersonal", ZoneDE: "Chemikalienlager, Beizbaeder", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1113", NameDE: "Einatmen Isocyanat-Dampf", NameEN: "Inhalation isocyanate vapour", RequiredComponentTags: []string{"chemical_risk", "high_temperature"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 80, ScenarioDE: "Isocyanatdaempfe bei PU-Verarbeitung eingeatmet", TriggerDE: "Fehlende Absaugung, hohe Temperatur", HarmDE: "Isocyanat-Asthma, Sensibilisierung", AffectedDE: "Bedienpersonal", ZoneDE: "PU-Schaeumanlage, Lackierbereich", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1114", NameDE: "Einatmen Ammoniak", NameEN: "Inhalation ammonia", RequiredComponentTags: []string{"chemical_risk", "high_pressure"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 78, ScenarioDE: "Ammoniak tritt aus Kaelteanlage aus", TriggerDE: "Leitungsleck, Ventildefekt", HarmDE: "Veraetzung Atemwege, Lungenoedem", AffectedDE: "Bedienpersonal, Umgebung", ZoneDE: "Maschinenraum, Kaelteanlage", DefaultSeverity: 4, DefaultExposure: 2, }, // === Chemisch Hautkontakt (5) === { ID: "HP1115", NameDE: "Hautkontakt Saeure", NameEN: "Skin contact acid", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 78, ScenarioDE: "Saeure gelangt auf ungeschuetzte Haut", TriggerDE: "Spritzer beim Umfuellen, defekte Handschuhe", HarmDE: "Veraetzung, Narbenbildung", AffectedDE: "Bedienpersonal", ZoneDE: "Umfuellplatz, Beizanlage", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1116", NameDE: "Hautkontakt Lauge", NameEN: "Skin contact alkali", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 75, ScenarioDE: "Lauge (NaOH, KOH) gelangt auf Haut", TriggerDE: "Spritzer, defekte Leitung", HarmDE: "Tiefe Veraetzung, Koliquationsnekrose", AffectedDE: "Bedienpersonal", ZoneDE: "Reinigungsanlage, CIP-Station", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1117", NameDE: "Hautkontakt Mineral-/Hydraulikoel", NameEN: "Skin contact mineral/hydraulic oil", RequiredComponentTags: []string{"chemical_risk", "hydraulic_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 55, ScenarioDE: "Dauernder Hautkontakt mit Oel ohne Handschuhe", TriggerDE: "Fehlende PSA, oelbenetztes Werkstueck", HarmDE: "Dermatitis, Oelakne", AffectedDE: "Bedienpersonal", ZoneDE: "Maschinenumgebung, Werkzeugwechsel", DefaultSeverity: 2, DefaultExposure: 4, }, { ID: "HP1118", NameDE: "Hautkontakt Kuehlschmierstoff", NameEN: "Skin contact coolant", RequiredComponentTags: []string{"chemical_risk", "cutting_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 58, ScenarioDE: "KSS-Spritzer treffen ungeschuetzte Haut", TriggerDE: "Spritzender KSS bei Bearbeitung, fehlende PSA", HarmDE: "Kontaktekzem, Allergisierung", AffectedDE: "Bedienpersonal", ZoneDE: "Zerspanungsbereich, KSS-Wanne", DefaultSeverity: 2, DefaultExposure: 4, }, { ID: "HP1119", NameDE: "Hautkontakt Epoxidharz", NameEN: "Skin contact epoxy resin", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 72, ScenarioDE: "Epoxidharz gelangt auf Haut bei Laminierarbeiten", TriggerDE: "Fehlende Handschuhe, Spritzer", HarmDE: "Allergische Dermatitis, Sensibilisierung", AffectedDE: "Laminierer, Bedienpersonal", ZoneDE: "Laminierplatz, Mischbereich", DefaultSeverity: 3, DefaultExposure: 3, }, // === Chemisch Augenkontakt (3) === { ID: "HP1120", NameDE: "Augenkontakt Chemikalienspritzer", NameEN: "Eye contact chemical splash", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 78, ScenarioDE: "Chemikalie spritzt ins Auge", TriggerDE: "Umfuellen ohne Schutzbrille, Leitungsriss", HarmDE: "Augenvraetzung, Erblindung", AffectedDE: "Bedienpersonal", ZoneDE: "Umfuellplatz, Behaelterbereich", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1121", NameDE: "Augenkontakt chemischer Dampf", NameEN: "Eye contact chemical vapour", RequiredComponentTags: []string{"chemical_risk", "high_temperature"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Aetzende Daempfe reizen Augen", TriggerDE: "Fehlende Absaugung, offener Behaelter", HarmDE: "Augenreizung, Hornhautschaden", AffectedDE: "Bedienpersonal", ZoneDE: "Beizanlage, Galvanik", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1122", NameDE: "Augenkontakt Staub", NameEN: "Eye contact dust", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 60, ScenarioDE: "Staub gelangt in ungeschuetzte Augen", TriggerDE: "Schleifen/Saegen ohne Schutzbrille, Wind", HarmDE: "Augenreizung, Fremdkoerper", AffectedDE: "Bedienpersonal", ZoneDE: "Bearbeitungsplatz", DefaultSeverity: 2, DefaultExposure: 4, }, // === Chemisch Verschlucken (2) === { ID: "HP1123", NameDE: "Verschlucken durch Kontamination", NameEN: "Ingestion by contamination", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Chemikalie gelangt ueber kontaminierte Haende in Mund", TriggerDE: "Essen/Trinken am Arbeitsplatz, fehlende Hygiene", HarmDE: "Vergiftung, Veraetzung Speiseroehre", AffectedDE: "Bedienpersonal", ZoneDE: "Arbeitsplatz, Pausenbereich", DefaultSeverity: 3, DefaultExposure: 2, }, { ID: "HP1124", NameDE: "Verschlucken durch Verwechslung", NameEN: "Ingestion by mix-up", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 62, ScenarioDE: "Chemikalie wird mit Getraenk verwechselt", TriggerDE: "Umfuellen in Trinkflaschen, fehlende Kennzeichnung", HarmDE: "Akute Vergiftung", AffectedDE: "Bedienpersonal", ZoneDE: "Arbeitsplatz, Lagerbereich", DefaultSeverity: 4, DefaultExposure: 1, }, // === Chemisch Brand (5) === { ID: "HP1125", NameDE: "Loesemittelbrand", NameEN: "Solvent fire", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M054", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 80, ScenarioDE: "Loesemitteldaempfe entzuenden sich", TriggerDE: "Zuendquelle nahe offenem Behaelter, Funke", HarmDE: "Brandverletzung, Rauchvergiftung", AffectedDE: "Bedienpersonal, Umgebung", ZoneDE: "Lackierbereich, Lagerraum", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1126", NameDE: "Staubbrand/-explosion", NameEN: "Dust fire/explosion", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M054", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 82, ScenarioDE: "Brennbarer Staub entzuendet sich oder explodiert", TriggerDE: "Staubablagerung + Zuendquelle, Aufwirbelung", HarmDE: "Explosion, Verbrennung, Tod", AffectedDE: "Alle Personen im Bereich", ZoneDE: "Muehle, Silo, Filter, Foerderstrecke", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1127", NameDE: "Gasbrand", NameEN: "Gas fire", RequiredComponentTags: []string{"chemical_risk", "high_pressure"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M051", "M054"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 82, ScenarioDE: "Austretendes Gas entzuendet sich", TriggerDE: "Undichte Gasleitung, offene Flamme", HarmDE: "Stichflamme, schwere Verbrennung", AffectedDE: "Bedienpersonal, Umgebung", ZoneDE: "Gasleitung, Brenner", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1128", NameDE: "Oelbrand Hydraulikanlage", NameEN: "Oil fire hydraulic system", RequiredComponentTags: []string{"hydraulic_part", "high_temperature"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M051", "M054"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 78, ScenarioDE: "Hydraulikoel entzuendet sich an heisser Oberflaeche", TriggerDE: "Oelleckage auf heisse Maschinenteile", HarmDE: "Oelbrand, schwere Verbrennung", AffectedDE: "Bedienpersonal", ZoneDE: "Hydraulikanlage, heisse Zonen", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1129", NameDE: "Metallbrand (Leichtmetall)", NameEN: "Metal fire (light metal)", RequiredComponentTags: []string{"chemical_risk", "high_temperature", "cutting_part"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M054", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 80, ScenarioDE: "Magnesium-/Aluminiumspaene entzuenden sich", TriggerDE: "Funke bei Bearbeitung, KSS-Ausfall", HarmDE: "Metallbrand, extreme Hitze", AffectedDE: "Bedienpersonal", ZoneDE: "Zerspanungsbereich, Spaenesammelbehaelter", DefaultSeverity: 5, DefaultExposure: 2, }, // === Chemisch Explosion (5) === { ID: "HP1130", NameDE: "Staubexplosion Silo", NameEN: "Dust explosion silo", RequiredComponentTags: []string{"chemical_risk", "structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M054", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 85, ScenarioDE: "Staubexplosion im Silo oder Filteranlage", TriggerDE: "Zuendquelle bei explosionsfaehiger Staubkonzentration", HarmDE: "Tod durch Explosion/Einsturz", AffectedDE: "Alle Personen im Bereich", ZoneDE: "Silo, Filter, Rohrleitungen", DefaultSeverity: 5, DefaultExposure: 1, }, { ID: "HP1131", NameDE: "Gasexplosion geschlossener Raum", NameEN: "Gas explosion enclosed space", RequiredComponentTags: []string{"chemical_risk", "high_pressure"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M051", "M054"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 85, ScenarioDE: "Gas sammelt sich und explodiert bei Zuendung", TriggerDE: "Gasleck in geschlossenem Raum, Zuendquelle", HarmDE: "Toedliche Druckwelle", AffectedDE: "Alle Personen im Raum", ZoneDE: "Geschlossener Raum, Keller, Grube", DefaultSeverity: 5, DefaultExposure: 1, }, { ID: "HP1132", NameDE: "Dampfexplosion", NameEN: "Steam explosion", RequiredComponentTags: []string{"high_pressure", "high_temperature"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"fire_explosion", "thermal_hazard"}, SuggestedMeasureIDs: []string{"M001", "M051", "M054"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 82, ScenarioDE: "Wasser auf heisse Schmelze erzeugt Dampfexplosion", TriggerDE: "Wassereinbruch in Schmelze, nasses Werkzeug", HarmDE: "Schmelzeauswurf, Tod", AffectedDE: "Giesser, Umstehende", ZoneDE: "Giessbereich, Schmelzofen", DefaultSeverity: 5, DefaultExposure: 1, }, { ID: "HP1133", NameDE: "Aerosolexplosion Spruehanlage", NameEN: "Aerosol explosion spray plant", RequiredComponentTags: []string{"chemical_risk", "high_pressure"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M054", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 78, ScenarioDE: "Spruehnebel bildet explosionsfaehiges Gemisch", TriggerDE: "Fehlende Lueftung, elektrostatischer Funke", HarmDE: "Explosion, Brandverletzung", AffectedDE: "Bedienpersonal", ZoneDE: "Spruehlackierkabine", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1134", NameDE: "Druckbehaelter-Explosion", NameEN: "Pressure vessel explosion", RequiredComponentTags: []string{"high_pressure", "stored_energy"}, RequiredEnergyTags: []string{"pneumatic_pressure"}, GeneratedHazardCats: []string{"fire_explosion", "pneumatic_hydraulic"}, SuggestedMeasureIDs: []string{"M001", "M051", "M054"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 85, ScenarioDE: "Druckbehaelter explodiert durch Ueberdruck oder Korrosion", TriggerDE: "Sicherheitsventil defekt, fehlende Pruefung", HarmDE: "Toedliche Druckwelle, Splitter", AffectedDE: "Alle Personen im Bereich", ZoneDE: "Druckbehaelter, Umgebung", DefaultSeverity: 5, DefaultExposure: 1, }, // === Chemisch CMR (3) === { ID: "HP1135", NameDE: "Asbest-Exposition Altanlagen", NameEN: "Asbestos exposure old plants", RequiredComponentTags: []string{"chemical_risk", "structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 82, ScenarioDE: "Asbestfasern werden bei Demontage/Wartung freigesetzt", TriggerDE: "Bohren/Saegen in Asbestmaterial, Abrissarbeiten", HarmDE: "Asbestose, Mesotheliom", AffectedDE: "Wartungspersonal, Abbrucharbeiter", ZoneDE: "Altanlage, Dichtungen, Isolierungen", DefaultSeverity: 5, DefaultExposure: 1, }, { ID: "HP1136", NameDE: "Benzol-Exposition", NameEN: "Benzene exposure", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 80, ScenarioDE: "Einatmen von Benzoldaempfen bei Chemikalienumgang", TriggerDE: "Offene Behaelter, fehlende Absaugung", HarmDE: "Leukaemie bei chronischer Exposition", AffectedDE: "Laborkraefte, Bedienpersonal", ZoneDE: "Chemielabor, Tankanlage", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1137", NameDE: "Chromat-Exposition Oberflaechenbehandlung", NameEN: "Chromate exposure surface treatment", RequiredComponentTags: []string{"chemical_risk", "high_temperature"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 80, ScenarioDE: "Chrom(VI)-Verbindungen freigesetzt bei Galvanik", TriggerDE: "Chrombad-Aerosol, fehlende Absaugung", HarmDE: "Nasenkrebs, Kontaktallergie", AffectedDE: "Galvaniseur", ZoneDE: "Chrombad, Galvanikanlage", DefaultSeverity: 5, DefaultExposure: 3, }, // === Biologisch (5) === { ID: "HP1138", NameDE: "Legionellen in Kuehlwasser", NameEN: "Legionella in cooling water", RequiredComponentTags: []string{"chemical_risk", "structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 72, ScenarioDE: "Legionellen vermehren sich im Kuehlkreislauf", TriggerDE: "Stagnation, Temperatur 25-50C, fehlende Wartung", HarmDE: "Legionaerspneumonie", AffectedDE: "Bedienpersonal, Umgebung", ZoneDE: "Kuehlturm, KSS-Anlage", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1139", NameDE: "Schimmelpilz in Lueftungsanlage", NameEN: "Mold in ventilation system", RequiredComponentTags: []string{"structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 60, ScenarioDE: "Schimmelsporen aus Lueftung werden eingeatmet", TriggerDE: "Feuchtigkeit im Kanal, fehlende Filterwartung", HarmDE: "Allergische Alveolitis", AffectedDE: "Raumnutzer", ZoneDE: "Lueftungskanal, Filterbereich", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1140", NameDE: "Endotoxin-Exposition organischer Staub", NameEN: "Endotoxin exposure organic dust", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Endotoxine in organischem Staub eingeatmet", TriggerDE: "Verarbeitung Getreide/Baumwolle, Kompostierung", HarmDE: "Organic Dust Toxic Syndrome", AffectedDE: "Bedienpersonal", ZoneDE: "Schuettgutverarbeitung, Lager", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1141", NameDE: "Zeckenbiss bei Ausseneinsatz", NameEN: "Tick bite during outdoor work", RequiredComponentTags: []string{"structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E01"}, Priority: 50, ScenarioDE: "Zeckenstich bei Arbeiten im Gruenen", TriggerDE: "Arbeit in Gras/Unterholz, fehlende Schutzkleidung", HarmDE: "Borreliose, FSME", AffectedDE: "Aussenpersonal, Forstarbeiter", ZoneDE: "Freigelände, Wald, Wiese", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1142", NameDE: "Blutkontakt Erste-Hilfe", NameEN: "Blood contact first aid", RequiredComponentTags: []string{"structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E01"}, Priority: 55, ScenarioDE: "Kontakt mit Blut bei Erster Hilfe", TriggerDE: "Offene Wunde, fehlende Einmalhandschuhe", HarmDE: "Hepatitis B/C, HIV-Infektion", AffectedDE: "Ersthelfer", ZoneDE: "Unfallort, Sanitaetsraum", DefaultSeverity: 4, DefaultExposure: 1, }, // === Strahlung (5) === { ID: "HP1143", NameDE: "UV-Strahlung Schweisslichtbogen", NameEN: "UV radiation welding arc", RequiredComponentTags: []string{"radiation_risk", "high_temperature"}, RequiredEnergyTags: []string{"radiation"}, GeneratedHazardCats: []string{"radiation_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 75, ScenarioDE: "UV-Strahlung vom Schweisslichtbogen trifft Augen/Haut", TriggerDE: "Schweissen ohne Schutzschild, Reflexion", HarmDE: "Verblitzen, Hautkrebs", AffectedDE: "Schweisser, Nachbarpersonal", ZoneDE: "Schweissplatz, Umgebung", DefaultSeverity: 3, DefaultExposure: 4, }, { ID: "HP1144", NameDE: "Infrarotstrahlung Gluehende Werkstuecke", NameEN: "IR radiation glowing workpieces", RequiredComponentTags: []string{"high_temperature", "radiation_risk"}, RequiredEnergyTags: []string{"radiation", "thermal"}, GeneratedHazardCats: []string{"radiation_hazard", "thermal_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 65, ScenarioDE: "IR-Strahlung gluehender Teile schaedigt Augen", TriggerDE: "Fehlende IR-Schutzbrille, langer Blickkontakt", HarmDE: "Grauer Star (Feuerstar)", AffectedDE: "Schmiede, Giesser", ZoneDE: "Schmiedebereich, Gluehzone", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1145", NameDE: "Roentgenstrahlung Pruefanlage", NameEN: "X-ray radiation testing system", RequiredComponentTags: []string{"radiation_risk", "sensor_part"}, RequiredEnergyTags: []string{"radiation"}, GeneratedHazardCats: []string{"radiation_hazard"}, SuggestedMeasureIDs: []string{"M001", "M054"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 80, ScenarioDE: "Ionisierende Strahlung aus Roentgenpruefanlage", TriggerDE: "Defekte Abschirmung, Zugang bei Betrieb", HarmDE: "Strahlenkrankheit, Krebs", AffectedDE: "Pruefpersonal", ZoneDE: "Roentgenraum, Kontrollbereich", DefaultSeverity: 5, DefaultExposure: 1, }, { ID: "HP1146", NameDE: "Laserstrahl Auge/Haut", NameEN: "Laser beam eye/skin", RequiredComponentTags: []string{"radiation_risk"}, RequiredEnergyTags: []string{"radiation"}, GeneratedHazardCats: []string{"radiation_hazard"}, SuggestedMeasureIDs: []string{"M001", "M005", "M054"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 82, ScenarioDE: "Laserstrahl trifft Auge oder Haut", TriggerDE: "Reflexion, offene Abdeckung, fehlende Brille", HarmDE: "Netzhautverbrennung, Erblindung", AffectedDE: "Bedienpersonal", ZoneDE: "Laserarbeitsraum, Strahlweg", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1147", NameDE: "Elektromagnetisches Feld HF-Anlage", NameEN: "EMF high-frequency system", RequiredComponentTags: []string{"radiation_risk", "electrical_part"}, RequiredEnergyTags: []string{"electromagnetic"}, GeneratedHazardCats: []string{"radiation_hazard", "emc_hazard"}, SuggestedMeasureIDs: []string{"M001", "M054"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 68, ScenarioDE: "Starkes EMF-Feld durch HF-Anlage/Induktionsofen", TriggerDE: "Aufenthalt im Nahfeld, fehlende Abschirmung", HarmDE: "Erwaermung Gewebe, Herzschrittmacher", AffectedDE: "Bedienpersonal, Traeger med. Implantate", ZoneDE: "HF-Anlage, Induktionsspule", DefaultSeverity: 3, DefaultExposure: 2, }, // === Laerm spezifisch (5) === { ID: "HP1148", NameDE: "Impulslaerm Stanzpresse", NameEN: "Impulse noise punch press", RequiredComponentTags: []string{"noise_source", "high_force"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"ergonomic_hazard", "noise_vibration"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E01", "E20"}, Priority: 72, ScenarioDE: "Impulslaerm bei jedem Stanzhub", TriggerDE: "Stanzvorgang ohne Schallschutzkabine", HarmDE: "Akutes Knalltrauma, Tinntius", AffectedDE: "Bedienpersonal", ZoneDE: "Stanzbereich, Umgebung", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1149", NameDE: "Ultraschall Reinigungsanlage", NameEN: "Ultrasound cleaning system", RequiredComponentTags: []string{"noise_source", "structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"ergonomic_hazard"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 55, ScenarioDE: "Ultraschall-Reiniger erzeugt Hochfrequenz-Laerm", TriggerDE: "Offener Betrieb, fehlender Gehoerschutz", HarmDE: "Kopfschmerz, Unwohlsein", AffectedDE: "Bedienpersonal", ZoneDE: "Ultraschallbad, Umgebung", DefaultSeverity: 2, DefaultExposure: 3, }, { ID: "HP1150", NameDE: "Tieffrequenter Laerm Kompressor", NameEN: "Low-frequency noise compressor", RequiredComponentTags: []string{"noise_source", "structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"ergonomic_hazard"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 55, ScenarioDE: "Tieffrequente Schallwellen durch Kompressor", TriggerDE: "Dauerlaerm, fehlende Koerperschallentkopplung", HarmDE: "Schlafstoerung, Konzentrationsverlust", AffectedDE: "Bedienpersonal, Bueropersonal", ZoneDE: "Kompressorraum, Nachbarbueers", DefaultSeverity: 2, DefaultExposure: 4, }, { ID: "HP1151", NameDE: "Dauerlaerm ueber 85 dB(A)", NameEN: "Continuous noise above 85 dB(A)", RequiredComponentTags: []string{"noise_source"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"ergonomic_hazard", "noise_vibration"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E01", "E20"}, Priority: 72, ScenarioDE: "Dauerhafte Laermbelastung ueber Ausloeeschwelle", TriggerDE: "Fehlender Gehoerschutz, mehrere Laermquellen", HarmDE: "Laermschwerhoerigkeit (BK 2301)", AffectedDE: "Bedienpersonal", ZoneDE: "Produktionshalle, Laermbereich", DefaultSeverity: 3, DefaultExposure: 4, }, { ID: "HP1152", NameDE: "Laerm verhindert Kommunikation", NameEN: "Noise prevents communication", RequiredComponentTags: []string{"noise_source"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"ergonomic_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E01"}, Priority: 68, ScenarioDE: "Warnsignale oder Zurufe sind nicht hoerbar", TriggerDE: "Hoher Umgebungslaerm, kein Blickkontakt", HarmDE: "Verzoegerte Reaktion, Unfall", AffectedDE: "Bedienpersonal, Kranfuehrer", ZoneDE: "Gesamter Laermbereich", DefaultSeverity: 3, DefaultExposure: 3, }, // === Erstickung (3) === { ID: "HP1153", NameDE: "Erstickung Inertgas-Flutung", NameEN: "Asphyxiation inert gas flooding", RequiredComponentTags: []string{"chemical_risk", "structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M001", "M054", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 85, ScenarioDE: "Inertgas verdraengt Sauerstoff im Raum", TriggerDE: "Stickstoff-/Argonleck, Loeschanlage loest aus", HarmDE: "Bewusstlosigkeit, Erstickungstod", AffectedDE: "Personen im Raum", ZoneDE: "Geschlossener Raum, Serverraum", DefaultSeverity: 5, DefaultExposure: 1, }, { ID: "HP1154", NameDE: "Erstickung Gaerung/Gasentwicklung", NameEN: "Asphyxiation fermentation/gas", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M001", "M054", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E20"}, Priority: 80, ScenarioDE: "CO2 aus Gaerprozess verdraengt Sauerstoff in Grube/Keller", TriggerDE: "Betreten ohne Gasmessung, fehlende Lueftung", HarmDE: "Bewusstlosigkeit, Tod", AffectedDE: "Bedienpersonal", ZoneDE: "Gaerkeller, Schacht, Grube", DefaultSeverity: 5, DefaultExposure: 1, }, { ID: "HP1155", NameDE: "Sauerstoffverbrauch geschlossener Raum", NameEN: "Oxygen depletion confined space", RequiredComponentTags: []string{"structural_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M001", "M054"}, SuggestedEvidenceIDs: []string{"E01", "E20"}, Priority: 82, ScenarioDE: "Sauerstoff wird durch Arbeiten in engem Raum verbraucht", TriggerDE: "Schweissen/Schneiden in Behaelter ohne Lueftung", HarmDE: "Sauerstoffmangel, Erstickung", AffectedDE: "Wartungspersonal", ZoneDE: "Behaelter, Tank, Kanal", DefaultSeverity: 5, DefaultExposure: 1, }, // === Extra patterns to reach 85 (14) === { ID: "HP1156", NameDE: "Thermischer Runaway Batteriespeicher", NameEN: "Thermal runaway battery storage", RequiredComponentTags: []string{"electrical_part", "high_temperature", "stored_energy"}, RequiredEnergyTags: []string{"electrical_energy"}, GeneratedHazardCats: []string{"fire_explosion", "electrical_hazard"}, SuggestedMeasureIDs: []string{"M001", "M054"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 82, ScenarioDE: "Batteriezelle geht in thermischen Runaway", TriggerDE: "Ueberladung, mechanischer Schaden, Kurzschluss", HarmDE: "Brand, toxischer Rauch", AffectedDE: "Bedienpersonal, Umgebung", ZoneDE: "Batterieraum, Ladestation", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1157", NameDE: "Flusssaeure-Exposition", NameEN: "Hydrofluoric acid exposure", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 85, ScenarioDE: "Flusssaeure gelangt auf Haut oder wird eingeatmet", TriggerDE: "Spritzer, offener Behaelter", HarmDE: "Tiefenveraetzung, Herzstillstand", AffectedDE: "Bedienpersonal", ZoneDE: "Beizanlage, Glasbearbeitung", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1158", NameDE: "Kohlenmonoxid-Vergiftung", NameEN: "Carbon monoxide poisoning", RequiredComponentTags: []string{"chemical_risk", "high_temperature"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M001", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E20"}, Priority: 82, ScenarioDE: "CO entsteht bei unvollstaendiger Verbrennung", TriggerDE: "Verbrennungsmotor in Halle, defekter Abzug", HarmDE: "CO-Vergiftung, Tod", AffectedDE: "Alle Personen im Raum", ZoneDE: "Halle, Tiefgarage, geschlossener Raum", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1159", NameDE: "Kontaktbrand heisse Partikel auf Kleidung", NameEN: "Clothing ignition hot particles", RequiredComponentTags: []string{"high_temperature"}, RequiredEnergyTags: []string{"thermal"}, GeneratedHazardCats: []string{"thermal_hazard", "fire_explosion"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 68, ScenarioDE: "Gluehende Partikel entzuenden Kleidung", TriggerDE: "Schweissspritzer auf Synthetikkleidung", HarmDE: "Verbrennung durch brennende Kleidung", AffectedDE: "Schweisser, Schleifer", ZoneDE: "Arbeitsplatz, Werkstatt", DefaultSeverity: 4, DefaultExposure: 3, }, { ID: "HP1160", NameDE: "Kaltverbrennung CO2-Loescher", NameEN: "Cold burn CO2 extinguisher", RequiredComponentTags: []string{"stored_energy"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M141"}, SuggestedEvidenceIDs: []string{"E01"}, Priority: 55, ScenarioDE: "CO2-Schnee verursacht Kaltverbrennung bei Loeschen", TriggerDE: "Anfassen des Trichters, Nahbereich-Loeschen", HarmDE: "Erfrierung Hand", AffectedDE: "Loeschpersonal", ZoneDE: "Loescherduese, Trichter", DefaultSeverity: 2, DefaultExposure: 1, }, { ID: "HP1161", NameDE: "Veraetzung Batteriesaeure", NameEN: "Battery acid burn", RequiredComponentTags: []string{"electrical_part", "chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental", "electrical_hazard"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 68, ScenarioDE: "Schwefelsaeure tritt aus beschaedigter Batterie aus", TriggerDE: "Kippen, Ueberladen, mechanischer Schaden", HarmDE: "Hautveraetzung, Augenschaden", AffectedDE: "Wartungspersonal", ZoneDE: "Batterieraum, USV-Anlage", DefaultSeverity: 3, DefaultExposure: 2, }, { ID: "HP1162", NameDE: "Reizgas-Freisetzung Leckage", NameEN: "Irritant gas release leak", RequiredComponentTags: []string{"chemical_risk", "high_pressure"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M001", "M124", "M141"}, SuggestedEvidenceIDs: []string{"E01", "E20"}, Priority: 75, ScenarioDE: "Reizgas (Chlor, SO2) tritt aus Anlage aus", TriggerDE: "Leitungsleck, Behaelterschaden", HarmDE: "Lungenoedem, Atemstillstand", AffectedDE: "Alle Personen im Bereich", ZoneDE: "Chemieanlage, Lagerbereich", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1163", NameDE: "Staubexplosion Metallpulver", NameEN: "Metal dust explosion", RequiredComponentTags: []string{"chemical_risk", "cutting_part"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"fire_explosion"}, SuggestedMeasureIDs: []string{"M001", "M054", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E08", "E20"}, Priority: 82, ScenarioDE: "Metallpulver/-staub explodiert bei Zuendquelle", TriggerDE: "Funke bei Aluminium-/Titanbearbeitung", HarmDE: "Explosion, schwere Verbrennung", AffectedDE: "Bedienpersonal", ZoneDE: "Schleifbereich, Filteranlage", DefaultSeverity: 5, DefaultExposure: 2, }, { ID: "HP1164", NameDE: "Hautresorption toxischer Stoffe", NameEN: "Dermal absorption toxic substances", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Giftstoff wird ueber Haut aufgenommen", TriggerDE: "Fehlende Handschuhe, verschmutzte Kleidung", HarmDE: "Systemische Vergiftung", AffectedDE: "Bedienpersonal", ZoneDE: "Arbeitsplatz, Chemikalienumgang", DefaultSeverity: 3, DefaultExposure: 3, }, { ID: "HP1165", NameDE: "Exotherme Reaktion Mischfehler", NameEN: "Exothermic reaction mixing error", RequiredComponentTags: []string{"chemical_risk"}, RequiredEnergyTags: []string{}, GeneratedHazardCats: []string{"material_environmental", "thermal_hazard"}, SuggestedMeasureIDs: []string{"M001", "M124"}, SuggestedEvidenceIDs: []string{"E01", "E20"}, Priority: 78, ScenarioDE: "Falsches Mischen erzeugt unkontrollierte Reaktion", TriggerDE: "Verwechslung Chemikalien, falsche Reihenfolge", HarmDE: "Explosion, Spritzer, Verbrennung", AffectedDE: "Bedienpersonal", ZoneDE: "Mischbereich, Reaktor", DefaultSeverity: 4, DefaultExposure: 2, }, { ID: "HP1166", NameDE: "Blendung Schweisslichtbogen", NameEN: "Glare from welding arc", RequiredComponentTags: []string{"radiation_risk", "high_temperature"}, RequiredEnergyTags: []string{"radiation"}, GeneratedHazardCats: []string{"radiation_hazard"}, SuggestedMeasureIDs: []string{"M054", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 65, ScenarioDE: "Schweisslichtbogen blendet Nachbarpersonal", TriggerDE: "Fehlende Abschirmung, Reflexion", HarmDE: "Voruebergehende Blendung, Unfall", AffectedDE: "Nachbarpersonal, Kranfuehrer", ZoneDE: "Sichtachse zum Schweissplatz", DefaultSeverity: 2, DefaultExposure: 3, }, { ID: "HP1167", NameDE: "Ozonbildung UV-Desinfektion", NameEN: "Ozone formation UV disinfection", RequiredComponentTags: []string{"radiation_risk", "chemical_risk"}, RequiredEnergyTags: []string{"radiation"}, GeneratedHazardCats: []string{"material_environmental", "radiation_hazard"}, SuggestedMeasureIDs: []string{"M124", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 60, ScenarioDE: "UV-Anlage erzeugt gesundheitsschaedliches Ozon", TriggerDE: "Fehlende Absaugung, offener Betrieb", HarmDE: "Atemwegsreizung, Lungenschaden", AffectedDE: "Bedienpersonal", ZoneDE: "UV-Anlage, Umgebung", DefaultSeverity: 3, DefaultExposure: 2, }, { ID: "HP1168", NameDE: "Mikrowellenstrahlung Leckage", NameEN: "Microwave radiation leakage", RequiredComponentTags: []string{"radiation_risk", "electrical_part"}, RequiredEnergyTags: []string{"electromagnetic"}, GeneratedHazardCats: []string{"radiation_hazard"}, SuggestedMeasureIDs: []string{"M001", "M054"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 65, ScenarioDE: "Mikrowellenstrahlung tritt aus defekter Abschirmung", TriggerDE: "Beschaedigte Dichtung, fehlende Wartung", HarmDE: "Gewebeerwaermung, Augenschaden", AffectedDE: "Bedienpersonal", ZoneDE: "Mikrowellenofen, Trockneranlage", DefaultSeverity: 3, DefaultExposure: 2, }, { ID: "HP1169", NameDE: "Radon in Kellerarbeitsplaetzen", NameEN: "Radon in basement workplaces", RequiredComponentTags: []string{"radiation_risk", "structural_part"}, RequiredEnergyTags: []string{"radiation"}, GeneratedHazardCats: []string{"radiation_hazard"}, SuggestedMeasureIDs: []string{"M124"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 55, ScenarioDE: "Radon sammelt sich in schlecht belueftetem Keller", TriggerDE: "Fehlende Lueftung, geologisch belastetes Gebiet", HarmDE: "Lungenkrebs bei Langzeitexposition", AffectedDE: "Kellerpersonal", ZoneDE: "Keller, Schacht, unterirdisch", DefaultSeverity: 4, DefaultExposure: 3, }, } }