package iace // GetMaintenanceExtPatterns returns 65 maintenance/lifecycle-specific hazard patterns // (HP700-HP729, HP900-HP934). All patterns have RequiredLifecycles set. func GetMaintenanceExtPatterns() []HazardPattern { return []HazardPattern{ // — Wartung allgemein (HP700-HP709) — {ID: "HP700", NameDE: "LOTO-Fehler: Maschine nicht freigeschaltet", NameEN: "LOTO failure: not locked out", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M054", "M082"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 95, ScenarioDE: "Arbeit ohne Freischaltung der Maschine", TriggerDE: "Fehlende LOTO-Prozedur", HarmDE: "Erfassen durch anlaufende Teile, Tod", AffectedDE: "Instandhalter", ZoneDE: "Gesamte Maschine", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP701", NameDE: "Restenergie trotz Abschaltung", NameEN: "Residual energy after shutdown", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard", "pneumatic_hydraulic"}, SuggestedMeasureIDs: []string{"M054", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 90, ScenarioDE: "Gespeicherte Energie entlaedt sich bei Wartung", TriggerDE: "Nicht abgelassener Druckspeicher", HarmDE: "Unkontrollierte Bewegung, Quetschung", AffectedDE: "Instandhalter", ZoneDE: "Antriebe, Speicher", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP702", NameDE: "Falsches Werkzeug bei Wartung", NameEN: "Wrong tool during maintenance", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 50, ScenarioDE: "Ungeeignetes oder defektes Werkzeug", TriggerDE: "Falscher Schraubenschluessel", HarmDE: "Abrutschen, Quetschung", AffectedDE: "Instandhalter", ZoneDE: "Wartungszugang", DefaultSeverity: 3, DefaultExposure: 4}, {ID: "HP703", NameDE: "Fehlende Qualifikation des Instandhalters", NameEN: "Insufficient maintainer qualification", RequiredComponentTags: []string{"electrical_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"electrical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Unqualifiziertes Personal an Elektrik", TriggerDE: "Keine Elektrofachkraft", HarmDE: "Stromschlag, Fehlverdrahtung", AffectedDE: "Instandhalter", ZoneDE: "Schaltschrank", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP704", NameDE: "Herabfallen schwerer Teile bei Demontage", NameEN: "Heavy parts falling during disassembly", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 75, ScenarioDE: "Schwere Teile fallen bei Demontage herab", TriggerDE: "Fehlende Abstuetzung", HarmDE: "Quetschung, Frakturen, Tod", AffectedDE: "Instandhalter", ZoneDE: "Wartungsbereich", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP705", NameDE: "Vergessenes Werkzeug in Maschine", NameEN: "Forgotten tool in machine", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Zurueckgelassenes Werkzeug wird Geschoss", TriggerDE: "Keine Werkzeugkontrolle", HarmDE: "Herausgeschleudertes Teil, Verletzungen", AffectedDE: "Bedienpersonal", ZoneDE: "Arbeitsraum", DefaultSeverity: 4, DefaultExposure: 2}, {ID: "HP706", NameDE: "Schnittwunden an scharfkantigen Teilen", NameEN: "Cuts on sharp-edged parts", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M005", "M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 45, ScenarioDE: "Scharfe Kanten und Grate verletzen", TriggerDE: "Fehlende Schutzhandschuhe", HarmDE: "Schnittwunden, Abschuerfungen", AffectedDE: "Instandhalter", ZoneDE: "Blechverkleidungen", DefaultSeverity: 2, DefaultExposure: 4}, {ID: "HP707", NameDE: "Verbrennung an heissen Teilen bei Wartung", NameEN: "Burn on hot parts during maintenance", RequiredComponentTags: []string{"high_temperature"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M005", "M082"}, SuggestedEvidenceIDs: []string{"E10"}, Priority: 60, ScenarioDE: "Maschine nicht abgekuehlt vor Wartung", TriggerDE: "Zu kurze Abkuehlzeit", HarmDE: "Kontaktverbrennungen", AffectedDE: "Instandhalter", ZoneDE: "Heizplatten, Motorgehaeuse", DefaultSeverity: 3, DefaultExposure: 4}, {ID: "HP708", NameDE: "Fehlende Wartungsfreigabe", NameEN: "Missing maintenance permit", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"safety_function_failure"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Wartung ohne formale Freigabe", TriggerDE: "Fehlender Erlaubnisschein", HarmDE: "Unerwarteter Maschinenbetrieb", AffectedDE: "Instandhalter", ZoneDE: "Gesamte Maschine", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP709", NameDE: "Biologische Gefaehrdung bei KSS-Wartung", NameEN: "Biological hazard MWF maintenance", RequiredComponentTags: []string{"chemical_risk"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M005", "M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 50, ScenarioDE: "Verkeimter Kuehlschmierstoff bei Wartung", TriggerDE: "Altes KSS, Biofilme", HarmDE: "Hautinfektionen, Atemwegsbeschwerden", AffectedDE: "Instandhalter", ZoneDE: "KSS-System", DefaultSeverity: 2, DefaultExposure: 3}, // — Einrichten / Umruesten (HP710-HP719) — {ID: "HP710", NameDE: "Falsche Parameter nach Umruestung", NameEN: "Wrong parameters after changeover", RequiredComponentTags: []string{"programmable"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"safety_function_failure"}, SuggestedMeasureIDs: []string{"M106", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 75, ScenarioDE: "Falsche Maschinenparameter nach Produktwechsel", TriggerDE: "Falsche Rezeptnummer", HarmDE: "Uebergeschwindigkeit, Werkzeugbruch", AffectedDE: "Einrichter", ZoneDE: "Bedienterminal", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP711", NameDE: "Quetschung bei Werkzeugwechsel", NameEN: "Crushing during tool change", RequiredComponentTags: []string{"moving_part", "high_force"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M003", "M054"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 80, ScenarioDE: "Schwere Werkzeuge manuell gewechselt", TriggerDE: "Kein Hebezeug, Finger eingeklemmt", HarmDE: "Quetschung, Amputation", AffectedDE: "Einrichter", ZoneDE: "Werkzeugaufnahme", DefaultSeverity: 4, DefaultExposure: 4}, {ID: "HP712", NameDE: "Unkontrollierte Bewegung bei Testlauf", NameEN: "Uncontrolled movement test run", RequiredComponentTags: []string{"moving_part", "programmable"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M106", "M054"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 80, ScenarioDE: "Testlauf mit Person im Gefahrenbereich", TriggerDE: "Volle Geschwindigkeit, kein Schutz", HarmDE: "Erfassen, Quetschen", AffectedDE: "Einrichter", ZoneDE: "Arbeitsraum", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP713", NameDE: "Einrichtbetrieb ohne reduzierte Geschwindigkeit", NameEN: "Setup without reduced speed", RequiredComponentTags: []string{"moving_part", "programmable"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M106", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 85, ScenarioDE: "Volle Geschwindigkeit im Einrichtmodus", TriggerDE: "Defekter Betriebsartschalter", HarmDE: "Erfassen bei voller Geschwindigkeit", AffectedDE: "Einrichter", ZoneDE: "Werkzeugbereich", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP714", NameDE: "Werkstueck faellt bei Aufspannung", NameEN: "Workpiece falls during clamping", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 55, ScenarioDE: "Werkstueck rutscht aus Spannvorrichtung", TriggerDE: "Ungenuegender Spanndruck", HarmDE: "Quetschung der Fuesse", AffectedDE: "Einrichter", ZoneDE: "Spannbereich", DefaultSeverity: 3, DefaultExposure: 4}, {ID: "HP715", NameDE: "Stromschlag bei Steckerwechsel", NameEN: "Shock during connector change", RequiredComponentTags: []string{"electrical_part"}, RequiredEnergyTags: []string{"electrical"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E09"}, Priority: 65, ScenarioDE: "Steckverbinder unter Spannung gewechselt", TriggerDE: "Nicht spannungsfrei", HarmDE: "Stromschlag, Lichtbogen", AffectedDE: "Einrichter", ZoneDE: "Sensoranschluesse", DefaultSeverity: 3, DefaultExposure: 3}, {ID: "HP716", NameDE: "Hydraulikdruck bei Werkzeugspannung", NameEN: "Hydraulic pressure tool clamping", RequiredComponentTags: []string{"hydraulic_part", "high_pressure"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"pneumatic_hydraulic"}, SuggestedMeasureIDs: []string{"M131", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 70, ScenarioDE: "Hydraulische Spannung mit hohen Kraeften", TriggerDE: "Hand im Spannbereich", HarmDE: "Quetschung, Amputation", AffectedDE: "Einrichter", ZoneDE: "Hydr. Spannbereich", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP717", NameDE: "Materialverwechslung bei Produktwechsel", NameEN: "Material mix-up product change", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 50, ScenarioDE: "Falsches Material nach Umruestung", TriggerDE: "Verwechslung, fehlende Kennzeichnung", HarmDE: "Werkzeugbruch, Splitterflug", AffectedDE: "Bedienpersonal", ZoneDE: "Materialzufuhr", DefaultSeverity: 3, DefaultExposure: 3}, {ID: "HP718", NameDE: "Absturz bei Einrichtung hoher Maschine", NameEN: "Fall during tall machine setup", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Einrichtarbeiten in Hoehe ohne sicheren Zugang", TriggerDE: "Improvisierte Aufstiegshilfe", HarmDE: "Absturz, Frakturen", AffectedDE: "Einrichter", ZoneDE: "Maschinenoberteil", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP719", NameDE: "Schutzeinrichtung nach Umruestung defekt", NameEN: "Faulty guard after changeover", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"setup"}, GeneratedHazardCats: []string{"safety_function_failure", "mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 80, ScenarioDE: "Schutzeinrichtung nicht korrekt justiert", TriggerDE: "Vergessene Nachjustierung", HarmDE: "Zugang zum Gefahrenbereich", AffectedDE: "Bedienpersonal", ZoneDE: "Schutztueren, Lichtgitter", DefaultSeverity: 5, DefaultExposure: 3}, // — Stoerungsbeseitigung (HP720-HP729) — {ID: "HP720", NameDE: "Zeitdruck bei Stoerungsbeseitigung", NameEN: "Time pressure fault clearing", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M054", "M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 80, ScenarioDE: "Eingriff ohne Freischaltung wegen Produktionsdruck", TriggerDE: "Bandstillstand, Lieferdruck", HarmDE: "Alle maschinentypischen Verletzungen", AffectedDE: "Bedienpersonal", ZoneDE: "Gesamte Maschine", DefaultSeverity: 5, DefaultExposure: 4}, {ID: "HP721", NameDE: "Verklemmtes Material loest sich schlagartig", NameEN: "Jammed material releases suddenly", RequiredComponentTags: []string{"moving_part", "high_force"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M054", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 85, ScenarioDE: "Gespanntes Material loest sich ploetzlich", TriggerDE: "Vorspannung, federndes Material", HarmDE: "Peitscheneffekt, Quetschung", AffectedDE: "Bedienpersonal", ZoneDE: "Einzugsstelle", DefaultSeverity: 4, DefaultExposure: 4}, {ID: "HP722", NameDE: "Manipulation Schutzeinrichtung bei Stoerung", NameEN: "Guard manipulation for fault clearing", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M054", "M082", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 90, ScenarioDE: "Schutztuer offen gehalten fuer schnelleren Zugang", TriggerDE: "Magnet am Sicherheitsschalter", HarmDE: "Zugang zu laufender Maschine", AffectedDE: "Bedienpersonal", ZoneDE: "Schutztueren", DefaultSeverity: 5, DefaultExposure: 4}, {ID: "HP723", NameDE: "Unerwarteter Wiederanlauf bei Stoerung", NameEN: "Unexpected restart fault clearing", RequiredComponentTags: []string{"moving_part", "programmable"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M106", "M054"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 95, ScenarioDE: "SPS startet Maschine automatisch nach Fehler", TriggerDE: "Fehlende Wiederanlaufsperre", HarmDE: "Erfassen durch anlaufende Teile, Tod", AffectedDE: "Alle im Gefahrenbereich", ZoneDE: "Arbeitsraum", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP724", NameDE: "Kontakt mit heissen Medien bei Stoerung", NameEN: "Hot media contact during fault", RequiredComponentTags: []string{"high_temperature", "high_pressure"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M005", "M082"}, SuggestedEvidenceIDs: []string{"E10"}, Priority: 70, ScenarioDE: "Heisses Medium tritt bei Reparatur aus", TriggerDE: "Nicht druckentlastete Leitung", HarmDE: "Verbruehungen, Dampfverbrennungen", AffectedDE: "Instandhalter", ZoneDE: "Medienleitungen", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP725", NameDE: "Absturz bei Stoerungsbeseitigung in Hoehe", NameEN: "Fall during fault clearing at height", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Eilige Stoerungsbeseitigung in Hoehe ohne Sicherung", TriggerDE: "Hektik, provisorischer Zugang", HarmDE: "Absturz, Frakturen", AffectedDE: "Bedienpersonal", ZoneDE: "Erhoehte Maschinenteile", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP726", NameDE: "Giftige Daempfe bei Stoerung", NameEN: "Toxic fumes during fault", RequiredComponentTags: []string{"chemical_risk"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M005", "M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Stoerung setzt giftige Daempfe frei", TriggerDE: "Ueberhitzung, Materialaustritt", HarmDE: "Vergiftung, Atemwegsschaeden", AffectedDE: "Bedienpersonal", ZoneDE: "Stoerungsstelle", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP727", NameDE: "Fehlende Beleuchtung bei Nacht-Stoerung", NameEN: "Insufficient light night fault", RequiredComponentTags: []string{"programmable"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"ergonomic_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 40, ScenarioDE: "Stoerungsbeseitigung nachts bei schlechtem Licht", TriggerDE: "Fehlendes Licht", HarmDE: "Stolpern, Fehlgriff", AffectedDE: "Nachtschichtpersonal", ZoneDE: "Maschinenumgebung", DefaultSeverity: 2, DefaultExposure: 3}, {ID: "HP728", NameDE: "Druckluftschlag bei Ventilstoerung", NameEN: "Air blast during valve fault", RequiredComponentTags: []string{"pneumatic_part", "high_pressure"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"pneumatic_hydraulic"}, SuggestedMeasureIDs: []string{"M131", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 65, ScenarioDE: "Druckluft entweicht schlagartig bei Reparatur", TriggerDE: "Nicht entlueftetes System", HarmDE: "Gehoerschaeden, Augenverletzung", AffectedDE: "Instandhalter", ZoneDE: "Pneumatikventile", DefaultSeverity: 3, DefaultExposure: 3}, {ID: "HP729", NameDE: "Fehldiagnose fuehrt zu Folgestoerung", NameEN: "Misdiagnosis causes secondary fault", RequiredComponentTags: []string{"programmable"}, RequiredLifecycles: []string{"fault_clearing"}, GeneratedHazardCats: []string{"safety_function_failure"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 55, ScenarioDE: "Falsche Fehleranalyse fuehrt zu unsachgemaesser Reparatur", TriggerDE: "Fehlendes Diagnosetool", HarmDE: "Folgestoerung mit groesserem Schaden", AffectedDE: "Bedienpersonal", ZoneDE: "Steuerung", DefaultSeverity: 4, DefaultExposure: 2}, // — Transport / Montage (HP900-HP907) — {ID: "HP900", NameDE: "Kippen der Maschine beim Transport", NameEN: "Machine tipping during transport", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"transport"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 80, ScenarioDE: "Maschine kippt wegen falschem Schwerpunkt", TriggerDE: "Falscher Anschlagpunkt", HarmDE: "Quetschung unter Maschine, Tod", AffectedDE: "Transportpersonal", ZoneDE: "Transportweg", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP901", NameDE: "Herabfallen bei Kranverladung", NameEN: "Falling load crane loading", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"transport"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 85, ScenarioDE: "Last loest sich aus Krananschlag", TriggerDE: "Falsches Anschlagmittel, Ueberlast", HarmDE: "Erschlagen, Tod", AffectedDE: "Alle im Schwenkbereich", ZoneDE: "Unter der Last", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP902", NameDE: "Quetschung beim Absetzen schwerer Lasten", NameEN: "Crushing when lowering loads", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"transport"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 75, ScenarioDE: "Finger/Fuesse zwischen Last und Unterlage", TriggerDE: "Zu nah an der Last", HarmDE: "Quetschung, Amputation", AffectedDE: "Anschlaeger", ZoneDE: "Absetzbereich", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP903", NameDE: "Rueckenschaden durch manuelles Tragen", NameEN: "Back injury manual carrying", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"transport"}, GeneratedHazardCats: []string{"ergonomic_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 50, ScenarioDE: "Maschinenteile manuell statt mit Hebehilfe getragen", TriggerDE: "Fehlende Hebemittel", HarmDE: "Bandscheibenvorfall", AffectedDE: "Montagepersonal", ZoneDE: "Transportwege", DefaultSeverity: 3, DefaultExposure: 4}, {ID: "HP904", NameDE: "Pendelnde Last am Kran", NameEN: "Swinging load on crane", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"transport"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Pendelnde Kranladung trifft Personen", TriggerDE: "Zu schnelles Schwenken, Wind", HarmDE: "Aufprall, Frakturen", AffectedDE: "Alle im Schwenkbereich", ZoneDE: "Kranbahn", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP905", NameDE: "Maschine rutscht vom Transportfahrzeug", NameEN: "Machine slides off vehicle", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"transport"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 75, ScenarioDE: "Unzureichende Ladungssicherung", TriggerDE: "Fehlende Zurrgurte, Vollbremsung", HarmDE: "Herabfallende Maschine, Sachschaden", AffectedDE: "Fahrer", ZoneDE: "Ladeflaeche", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP906", NameDE: "Kollision bei innerbetrieblichem Transport", NameEN: "Collision internal transport", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"transport"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 60, ScenarioDE: "Stapler kollidiert mit Personen", TriggerDE: "Eingeschraenkte Sicht, zu schnell", HarmDE: "Anfahrunfall, Quetschung", AffectedDE: "Fussgaenger", ZoneDE: "Transportwege", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP907", NameDE: "Verankerungsfehler bei Montage", NameEN: "Anchoring error installation", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"transport"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Maschine nicht korrekt verankert", TriggerDE: "Zu schwache Duebel, falscher Untergrund", HarmDE: "Verschiebung, Kippen", AffectedDE: "Bedienpersonal", ZoneDE: "Fundament", DefaultSeverity: 4, DefaultExposure: 2}, // — Inbetriebnahme (HP908-HP912) — {ID: "HP908", NameDE: "Erststart ohne komplette Schutzeinrichtungen", NameEN: "First start without guards", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"commissioning"}, GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 90, ScenarioDE: "Erststart vor Montage aller Schutzeinrichtungen", TriggerDE: "Termindruck, fehlende Abnahme", HarmDE: "Offene Gefahrstellen", AffectedDE: "IBN-Personal", ZoneDE: "Gesamte Maschine", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP909", NameDE: "Kalibrierungsfehler verursacht Ueberfahrt", NameEN: "Calibration error overtravel", RequiredComponentTags: []string{"moving_part", "programmable"}, RequiredLifecycles: []string{"commissioning"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M106", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 75, ScenarioDE: "Falsche Achskalibrierung fuehrt zu Ueberfahrt", TriggerDE: "Vertauschte Achsen", HarmDE: "Kollision, Maschinenbruch", AffectedDE: "IBN-Personal", ZoneDE: "Verfahrbereiche", DefaultSeverity: 4, DefaultExposure: 2}, {ID: "HP910", NameDE: "Unerwartetes Verhalten bei Probebetrieb", NameEN: "Unexpected behaviour trial run", RequiredComponentTags: []string{"programmable"}, RequiredLifecycles: []string{"commissioning"}, GeneratedHazardCats: []string{"safety_function_failure"}, SuggestedMeasureIDs: []string{"M106", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 70, ScenarioDE: "Neues Programm zeigt unvorhergesehenes Verhalten", TriggerDE: "Softwarefehler", HarmDE: "Unkontrollierte Bewegung", AffectedDE: "IBN-Personal", ZoneDE: "Arbeitsraum", DefaultSeverity: 4, DefaultExposure: 2}, {ID: "HP911", NameDE: "Not-Halt nicht geprueft bei IBN", NameEN: "E-stop not tested commissioning", RequiredComponentTags: []string{"electrical_part"}, RequiredLifecycles: []string{"commissioning"}, GeneratedHazardCats: []string{"safety_function_failure"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E09"}, Priority: 85, ScenarioDE: "Not-Halt vor Erstbetrieb nicht geprueft", TriggerDE: "Uebergangene Checkliste", HarmDE: "Kein Stopp im Notfall", AffectedDE: "Alle an Maschine", ZoneDE: "Not-Halt-Positionen", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP912", NameDE: "Medienanschluss vertauscht bei IBN", NameEN: "Media connection swapped", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"commissioning"}, GeneratedHazardCats: []string{"pneumatic_hydraulic"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 60, ScenarioDE: "Vertauschter Druckluft-/Hydraulikanschluss", TriggerDE: "Verwechslung, fehlende Kennzeichnung", HarmDE: "Falsche Bewegungsrichtung, Berstgefahr", AffectedDE: "IBN-Personal", ZoneDE: "Anschluesse", DefaultSeverity: 3, DefaultExposure: 2}, // — Reinigung (HP913-HP917) — {ID: "HP913", NameDE: "Nassreinigung nahe Elektrik", NameEN: "Wet cleaning near electrics", RequiredComponentTags: []string{"electrical_part"}, RequiredEnergyTags: []string{"electrical"}, RequiredLifecycles: []string{"cleaning"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E09"}, Priority: 75, ScenarioDE: "Wasser gelangt in Schaltschrank", TriggerDE: "Hochdruckreiniger nahe Elektrik", HarmDE: "Kurzschluss, Stromschlag", AffectedDE: "Reinigungspersonal", ZoneDE: "Schaltschrank", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP914", NameDE: "Giftige Reinigungsmittel-Daempfe", NameEN: "Toxic cleaner fumes", RequiredComponentTags: []string{"chemical_risk"}, RequiredLifecycles: []string{"cleaning"}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M005", "M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Reinigungsmittel-Daempfe in geschlossenem Raum", TriggerDE: "Fehlende Lueftung", HarmDE: "Atemwegsveraetzung, Vergiftung", AffectedDE: "Reinigungspersonal", ZoneDE: "Maschineninneres", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP915", NameDE: "Hochdruckreiniger-Verletzung", NameEN: "High-pressure cleaner injury", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"cleaning"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 60, ScenarioDE: "Hochdruckstrahl verletzt Haut", TriggerDE: "Zu geringer Abstand", HarmDE: "Injektionsverletzung, Infektion", AffectedDE: "Reinigungspersonal", ZoneDE: "Reinigungsbereich", DefaultSeverity: 3, DefaultExposure: 3}, {ID: "HP916", NameDE: "Reinigung bei laufender Maschine", NameEN: "Cleaning during operation", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"cleaning"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M054", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 85, ScenarioDE: "Reinigung ohne Abschaltung der Maschine", TriggerDE: "Zeitdruck", HarmDE: "Einzug, Quetschung, Aufwickeln", AffectedDE: "Reinigungspersonal", ZoneDE: "Rotierende Teile", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP917", NameDE: "Nassrutschiger Boden nach Reinigung", NameEN: "Wet slippery floor after cleaning", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"cleaning"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 45, ScenarioDE: "Nasser Boden nach Maschinenreinigung", TriggerDE: "Fehlende Absperrung", HarmDE: "Sturz, Frakturen", AffectedDE: "Alle Personen", ZoneDE: "Werkstattboden", DefaultSeverity: 2, DefaultExposure: 4}, // — Demontage / Entsorgung (HP918-HP922) — {ID: "HP918", NameDE: "Restmedien in demontierten Leitungen", NameEN: "Residual media dismantled piping", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"decommissioning"}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 65, ScenarioDE: "Oel/Chemikalien treten aus getrennten Leitungen", TriggerDE: "Nicht entleerte Leitungen", HarmDE: "Veraetzung, Kontamination", AffectedDE: "Abbruchpersonal", ZoneDE: "Trennstellen", DefaultSeverity: 3, DefaultExposure: 3}, {ID: "HP919", NameDE: "Asbestexposition bei Altmaschine", NameEN: "Asbestos old machine demolition", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"decommissioning"}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M005", "M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 85, RequiresExpertCalculation: true, ExpertHintDE: "Schadstoffgutachten gemaess TRGS 519 erforderlich.", ScenarioDE: "Asbesthaltiges Material wird freigesetzt", TriggerDE: "Keine Vorab-Ermittlung", HarmDE: "Asbestose, Lungenkrebs", AffectedDE: "Abbruchpersonal", ZoneDE: "Alte Dichtungen/Isolierungen", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP920", NameDE: "Kontaminierte Teile bei Entsorgung", NameEN: "Contaminated parts disposal", RequiredComponentTags: []string{"chemical_risk"}, RequiredLifecycles: []string{"decommissioning"}, GeneratedHazardCats: []string{"material_environmental"}, SuggestedMeasureIDs: []string{"M005", "M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 55, ScenarioDE: "Kontaminierte Teile unsachgemaess entsorgt", TriggerDE: "Fehlende Trennung", HarmDE: "Umweltverschmutzung, Hautkontakt", AffectedDE: "Entsorgungspersonal", ZoneDE: "Demontagebereich", DefaultSeverity: 2, DefaultExposure: 3}, {ID: "HP921", NameDE: "Scharfe Kanten bei Zerschneidung", NameEN: "Sharp edges cutting scrap", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"decommissioning"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M005", "M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 50, ScenarioDE: "Scharfe Kanten beim Zerteilen der Maschine", TriggerDE: "Trennschleifen, Brennschneiden", HarmDE: "Schnittwunden, Splitterverletzungen", AffectedDE: "Abbruchpersonal", ZoneDE: "Schneidbereich", DefaultSeverity: 3, DefaultExposure: 3}, {ID: "HP922", NameDE: "Instabilitaet bei stueckweisem Abbruch", NameEN: "Instability stepwise demolition", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"decommissioning"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Restbauwerk stuerzt unkontrolliert ein", TriggerDE: "Falsche Abbruchreihenfolge", HarmDE: "Verschuettung, Tod", AffectedDE: "Abbruchpersonal", ZoneDE: "Restkonstruktion", DefaultSeverity: 5, DefaultExposure: 2}, // — Inspektion / Pruefung (HP923-HP927) — {ID: "HP923", NameDE: "Pruefung unter Last (Belastungstest)", NameEN: "Test under load", RequiredComponentTags: []string{"structural_part", "high_force"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E08", "E20"}, Priority: 80, ScenarioDE: "Bauteilversagen bei Maximallast", TriggerDE: "Materialermuedung, Riss", HarmDE: "Bruchstuecke, herabfallende Last", AffectedDE: "Pruefpersonal", ZoneDE: "Pruefstand", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP924", NameDE: "Druckpruefung mit Berstgefahr", NameEN: "Pressure test burst risk", RequiredComponentTags: []string{"high_pressure"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"pneumatic_hydraulic"}, SuggestedMeasureIDs: []string{"M131", "M082", "M141"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 85, RequiresExpertCalculation: true, ExpertHintDE: "Pruefung nur durch ZUeS gemaess BetrSichV.", ScenarioDE: "Behaelter versagt bei Druckpruefung", TriggerDE: "Wandstaerkenunterschreitung", HarmDE: "Bersten, Splitterflug, Tod", AffectedDE: "Pruefpersonal", ZoneDE: "Druckbehaelter", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP925", NameDE: "Funktionstest mit offener Schutzeinrichtung", NameEN: "Function test open guard", RequiredComponentTags: []string{"moving_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M054", "M082"}, SuggestedEvidenceIDs: []string{"E08"}, Priority: 80, ScenarioDE: "Test erfordert offene Schutzeinrichtung", TriggerDE: "Sichtpruefung noetig", HarmDE: "Erfassen, Quetschen", AffectedDE: "Pruefpersonal", ZoneDE: "Maschinenarbeitsraum", DefaultSeverity: 5, DefaultExposure: 2}, {ID: "HP926", NameDE: "Messung an spannungsfuehrender Anlage", NameEN: "Measurement on energized system", RequiredComponentTags: []string{"electrical_part"}, RequiredEnergyTags: []string{"electrical"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"electrical_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E09"}, Priority: 75, ScenarioDE: "Messung unter Spannung bei Fehlersuche", TriggerDE: "Messgeraet rutscht ab", HarmDE: "Stromschlag, Lichtbogen", AffectedDE: "Elektrofachkraft", ZoneDE: "Schaltschrank", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP927", NameDE: "ZfP mit Strahlenquelle", NameEN: "NDT with radiation source", RequiredComponentTags: []string{"radiation_source"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"radiation_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 80, RequiresExpertCalculation: true, ExpertHintDE: "Strahlenschutzbeauftragter nach StrlSchV erforderlich.", ScenarioDE: "Radiographische Pruefung mit Roentgen/Gamma", TriggerDE: "Sperrbereich nicht eingerichtet", HarmDE: "Ionisierende Strahlung, Krebs", AffectedDE: "Pruefpersonal", ZoneDE: "Pruef-/Kontrollbereich", DefaultSeverity: 5, DefaultExposure: 2}, // — Fremdfirmen (HP928-HP931) — {ID: "HP928", NameDE: "Fehlende Einweisung Fremdfirma", NameEN: "Missing contractor induction", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"safety_function_failure"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Fremdfirma kennt ortsspezifische Gefahren nicht", TriggerDE: "Keine Sicherheitsunterweisung", HarmDE: "Alle Gefaehrdungen durch Unkenntnis", AffectedDE: "Fremdfirmenpersonal", ZoneDE: "Gesamter Betrieb", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP929", NameDE: "Sprachbarriere bei Sicherheitskommunikation", NameEN: "Language barrier safety communication", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"safety_function_failure"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 55, ScenarioDE: "Sicherheitsanweisungen nicht verstanden", TriggerDE: "Nur deutschsprachige Unterweisung", HarmDE: "Fehlverhalten durch Missverstaendnis", AffectedDE: "Fremdfirmenpersonal", ZoneDE: "Einsatzbereich", DefaultSeverity: 3, DefaultExposure: 3}, {ID: "HP930", NameDE: "Parallele Arbeiten ohne Koordination", NameEN: "Parallel work no coordination", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard", "safety_function_failure"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 75, ScenarioDE: "Mehrere Teams gleichzeitig an einer Anlage", TriggerDE: "Fehlende Koordination", HarmDE: "Unerwarteter Anlauf, Gefaehrdung", AffectedDE: "Alle Teams", ZoneDE: "Gesamte Anlage", DefaultSeverity: 5, DefaultExposure: 3}, {ID: "HP931", NameDE: "Schnittstellenproblem an Gewerkeuebergaengen", NameEN: "Interface problem trade boundaries", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"safety_function_failure"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 60, ScenarioDE: "Verantwortungsluecke zwischen Gewerken", TriggerDE: "Unklare Zustaendigkeiten", HarmDE: "Vernachlaessigte Sicherheit", AffectedDE: "Alle Gewerke", ZoneDE: "Schnittstellen", DefaultSeverity: 3, DefaultExposure: 3}, // — Notfall (HP932-HP934) — {ID: "HP932", NameDE: "Versperrte Fluchtwege bei Wartung", NameEN: "Blocked escape routes maintenance", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 70, ScenarioDE: "Material blockiert Flucht- und Rettungswege", TriggerDE: "Abgestelltes Material, Geruest", HarmDE: "Verzoegerte Evakuierung", AffectedDE: "Alle im Gebaeude", ZoneDE: "Fluchtwege", DefaultSeverity: 4, DefaultExposure: 3}, {ID: "HP933", NameDE: "Fehlende Erste-Hilfe am Wartungsort", NameEN: "Missing first aid maintenance site", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"mechanical_hazard"}, SuggestedMeasureIDs: []string{"M082"}, SuggestedEvidenceIDs: []string{"E20"}, Priority: 50, ScenarioDE: "Kein Erste-Hilfe-Material am abgelegenen Ort", TriggerDE: "Entfernter Standort", HarmDE: "Verzoegerte Erstversorgung", AffectedDE: "Instandhalter", ZoneDE: "Abgelegene Wartungsorte", DefaultSeverity: 3, DefaultExposure: 3}, {ID: "HP934", NameDE: "Brandbekaempfung bei Wartung", NameEN: "Firefighting during maintenance", RequiredComponentTags: []string{"structural_part"}, RequiredLifecycles: []string{"maintenance"}, GeneratedHazardCats: []string{"thermal_hazard"}, SuggestedMeasureIDs: []string{"M082", "M141"}, SuggestedEvidenceIDs: []string{"E10", "E20"}, Priority: 65, ScenarioDE: "Feuerloescher nicht erreichbar bei Wartung", TriggerDE: "Verstellter Loescher", HarmDE: "Brandausbreitung, Verbrennungen", AffectedDE: "Instandhalter", ZoneDE: "Wartungsbereich", DefaultSeverity: 4, DefaultExposure: 2}, } }