test(ai-sdk): GT #3 (commercial dishwasher) + fix Drehtisch keyword mislabel
Add ground_truth_warewashing.json + TestWarewashing_GTCoverage. The test runs
the UC-M narrative through the SAME chain as production (ParseNarrative ->
engine -> relevance + cyber filter), so keyword/gating fixes are measured on
the real hazard set, and false positives show up as "extra".
Class A (generic keyword hygiene): spuelarm/spuelfeld no longer map to library
component C004 ("Drehtisch" / rotary table) — that mislabelled the spray arm.
Keep the rotating_part tag. Removes the bogus "Drehtisch" hazard.
GT #3 baseline -> after Class A: recall 80% (unchanged), one false positive
(Drehtisch) removed. Kistenhub 97.1% and Bremse pinned mappings unchanged.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,146 @@
|
|||||||
|
package iace
|
||||||
|
|
||||||
|
import (
|
||||||
|
"encoding/json"
|
||||||
|
"os"
|
||||||
|
"path/filepath"
|
||||||
|
"sort"
|
||||||
|
"testing"
|
||||||
|
)
|
||||||
|
|
||||||
|
// GT #3 — commercial UNDERCOUNTER dishwasher (Winterhalter UC-M). Self-assessed
|
||||||
|
// ground truth: we can judge what a dishwasher is. The test runs the narrative
|
||||||
|
// through the SAME chain as production (ParseNarrative -> engine -> relevance
|
||||||
|
// filter + cyber-skip), so keyword/gating fixes are measured on the hazard set
|
||||||
|
// the user actually sees — not the raw pattern flood.
|
||||||
|
|
||||||
|
// Condensed UC-M limits_form narrative. Deliberately includes "Cool-Ausfuehrung"
|
||||||
|
// and "Filter" so the known false components (Kuehlaggregat, Absauganlage) are
|
||||||
|
// reproduced and visible in the baseline.
|
||||||
|
const warewashingNarrative = `Gewerbliche Untertisch-Geschirrspuelmaschine fuer Gastronomie-Kueche, ` +
|
||||||
|
`vernetzt ueber LAN und WLAN (Connected Wash Internetportal). Heisswasser-Boiler mit ` +
|
||||||
|
`Nachspueltemperatur ca. 85 Grad C, Tank mit Hygiene-Tankheizkoerper. Spuelpumpe 150-200 l/min ` +
|
||||||
|
`mit rotierenden Spuelfeldern und Spuelarmen, Ablaufpumpe. Eingebautes Dosiergeraet fuer Reiniger ` +
|
||||||
|
`und Klarspueler (aetzende Konzentrate). 4-fach-Laugenfiltration mit Filter. Doppelwandige Tuer ` +
|
||||||
|
`mit Sicherheitsschalter und Rastposition (Thermostopp). Elektromotor (Drehstrom) 400 V. ` +
|
||||||
|
`Touch-Steuerung (SPS) mit Bedienfeld und HMI, USB-Schnittstelle fuer Softwareupdates, ` +
|
||||||
|
`PIN-geschuetzter Servicetechniker-Fernzugriff. Cool-Ausfuehrung mit kalter Nachspuelung. ` +
|
||||||
|
`Untertischmontage. Eingreifen in die Spuelkammer moeglich. Aerosole und Daempfe der ` +
|
||||||
|
`Reinigungschemie gelangen in die Atemzone. Manuelles Be- und Entladen der Spuelkoerbe von Hand. ` +
|
||||||
|
`Reinigung und Wartung durch Servicetechniker. Branche Lebensmittel und Getraenke.`
|
||||||
|
|
||||||
|
// warewashingCyberCategories mirrors handlers.nativeCyberSecurityCategories —
|
||||||
|
// native cyber/AI hazards are routed to the CRA module, not the CE hazard log.
|
||||||
|
var warewashingCyberCategories = map[string]bool{
|
||||||
|
"unauthorized_access": true, "firmware_corruption": true, "cyber_resilience": true,
|
||||||
|
"logging_audit_failure": true, "cyber_network": true, "sensor_spoofing": true,
|
||||||
|
"ai_specific": true, "ai_misclassification": true, "false_classification": true,
|
||||||
|
"model_drift": true, "data_poisoning": true, "unintended_bias": true,
|
||||||
|
}
|
||||||
|
|
||||||
|
// warewashingEngineOutput runs the production chain and returns the filtered
|
||||||
|
// hazards/mitigations the user would see for the UC-M.
|
||||||
|
func warewashingEngineOutput() ([]Hazard, []Mitigation, int) {
|
||||||
|
res := ParseNarrative(warewashingNarrative, "Gewerbliche Untertisch-Geschirrspuelmaschine (vernetzt)")
|
||||||
|
|
||||||
|
var compIDs, compNames []string
|
||||||
|
for _, c := range res.Components {
|
||||||
|
if c.Negated {
|
||||||
|
continue
|
||||||
|
}
|
||||||
|
compIDs = append(compIDs, c.LibraryID)
|
||||||
|
compNames = append(compNames, c.NameDE)
|
||||||
|
}
|
||||||
|
var energyIDs []string
|
||||||
|
for _, e := range res.EnergySources {
|
||||||
|
energyIDs = append(energyIDs, e.SourceID)
|
||||||
|
}
|
||||||
|
lifecycles := append([]string{}, res.LifecyclePhases...)
|
||||||
|
lifecycles = append(lifecycles, "normal_operation", "maintenance", "cleaning", "setup", "fault_clearing")
|
||||||
|
|
||||||
|
input := MatchInput{
|
||||||
|
ComponentLibraryIDs: compIDs,
|
||||||
|
EnergySourceIDs: energyIDs,
|
||||||
|
LifecyclePhases: lifecycles,
|
||||||
|
CustomTags: res.CustomTags,
|
||||||
|
OperationalStates: append(res.OperationalStates, "normal_operation", "cleaning", "maintenance"),
|
||||||
|
HumanRoles: res.Roles,
|
||||||
|
MachineTypes: []string{"food_processing", "Gewerbliche Untertisch-Geschirrspuelmaschine (vernetzt)"},
|
||||||
|
}
|
||||||
|
|
||||||
|
out := NewPatternEngine().Match(input)
|
||||||
|
|
||||||
|
var kept []PatternMatch
|
||||||
|
for _, pm := range out.MatchedPatterns {
|
||||||
|
if !IsPatternRelevant(pm, warewashingNarrative, compNames) {
|
||||||
|
continue
|
||||||
|
}
|
||||||
|
allCyber := len(pm.HazardCats) > 0
|
||||||
|
for _, c := range pm.HazardCats {
|
||||||
|
if !warewashingCyberCategories[c] {
|
||||||
|
allCyber = false
|
||||||
|
}
|
||||||
|
}
|
||||||
|
if allCyber {
|
||||||
|
continue
|
||||||
|
}
|
||||||
|
kept = append(kept, pm)
|
||||||
|
}
|
||||||
|
filtered := *out
|
||||||
|
filtered.MatchedPatterns = kept
|
||||||
|
hazards, mitigations := patternsToHazardsAndMitigations(&filtered)
|
||||||
|
return hazards, mitigations, len(kept)
|
||||||
|
}
|
||||||
|
|
||||||
|
func TestWarewashing_GTCoverage(t *testing.T) {
|
||||||
|
gtPath := filepath.Join("testdata", "ground_truth_warewashing.json")
|
||||||
|
raw, err := os.ReadFile(gtPath)
|
||||||
|
if err != nil {
|
||||||
|
t.Fatalf("read GT: %v", err)
|
||||||
|
}
|
||||||
|
var gt GroundTruth
|
||||||
|
if err := json.Unmarshal(raw, >); err != nil {
|
||||||
|
t.Fatalf("parse GT: %v", err)
|
||||||
|
}
|
||||||
|
|
||||||
|
hazards, mitigations, nPatterns := warewashingEngineOutput()
|
||||||
|
t.Logf("Engine: %d patterns kept (relevance+cyber filter) -> %d hazards", nPatterns, len(hazards))
|
||||||
|
|
||||||
|
result := CompareBenchmark(>, hazards, mitigations)
|
||||||
|
precision := 0.0
|
||||||
|
if result.TotalEngine > 0 {
|
||||||
|
precision = float64(len(result.MatchedPairs)) / float64(result.TotalEngine)
|
||||||
|
}
|
||||||
|
t.Logf("=== Warewashing-GT (GT #3) Baseline ===")
|
||||||
|
t.Logf("Recall (Coverage): %.1f%% (%d/%d matched, %d missing)",
|
||||||
|
result.CoverageScore*100, len(result.MatchedPairs), result.TotalGT, len(result.MissingFromEngine))
|
||||||
|
t.Logf("Precision: %.1f%% (%d engine hazards, %d extra)",
|
||||||
|
precision*100, result.TotalEngine, len(result.ExtraInEngine))
|
||||||
|
|
||||||
|
if len(result.MissingFromEngine) > 0 {
|
||||||
|
t.Logf("--- MISSING (recall gaps) ---")
|
||||||
|
for _, m := range result.MissingFromEngine {
|
||||||
|
t.Logf(" MISS %s: %s", m.Nr, abbrev(m.HazardType, 60))
|
||||||
|
}
|
||||||
|
}
|
||||||
|
if len(result.ExtraInEngine) > 0 {
|
||||||
|
t.Logf("--- EXTRA (false positives / precision loss) ---")
|
||||||
|
names := make([]string, 0, len(result.ExtraInEngine))
|
||||||
|
for _, e := range result.ExtraInEngine {
|
||||||
|
n := e.Name
|
||||||
|
if n == "" {
|
||||||
|
n = e.Scenario
|
||||||
|
}
|
||||||
|
names = append(names, "["+e.Category+"] "+n)
|
||||||
|
}
|
||||||
|
sort.Strings(names)
|
||||||
|
for _, n := range names {
|
||||||
|
t.Logf(" EXTRA %s", abbrev(n, 85))
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
// Loose smoke floor for the baseline — fixes should push recall up, not down.
|
||||||
|
if result.CoverageScore < 0.4 {
|
||||||
|
t.Errorf("warewashing recall below 40%% floor: %.1f%%", result.CoverageScore*100)
|
||||||
|
}
|
||||||
|
}
|
||||||
@@ -101,7 +101,11 @@ func GetKeywordDictionary() []KeywordEntry {
|
|||||||
{Keywords: []string{"dampf", "wrasen", "schwaden", "brueden"}, ExtraTags: []string{"steam_emission", "high_temperature"}},
|
{Keywords: []string{"dampf", "wrasen", "schwaden", "brueden"}, ExtraTags: []string{"steam_emission", "high_temperature"}},
|
||||||
{Keywords: []string{"boiler", "spuelboiler", "nachspuelboiler", "tankheiz", "boilerheiz"}, ComponentIDs: []string{"C094"}, ExtraTags: []string{"heating_element", "high_temperature"}},
|
{Keywords: []string{"boiler", "spuelboiler", "nachspuelboiler", "tankheiz", "boilerheiz"}, ComponentIDs: []string{"C094"}, ExtraTags: []string{"heating_element", "high_temperature"}},
|
||||||
{Keywords: []string{"reiniger", "klarspueler", "spuelmittel", "reinigungsmittel", "reinigerkonzentrat", "spuelchemie", "dosiergeraet", "dosierpumpe", "sauglanze", "entkalker"}, ExtraTags: []string{"corrosive_chemical"}},
|
{Keywords: []string{"reiniger", "klarspueler", "spuelmittel", "reinigungsmittel", "reinigerkonzentrat", "spuelchemie", "dosiergeraet", "dosierpumpe", "sauglanze", "entkalker"}, ExtraTags: []string{"corrosive_chemical"}},
|
||||||
{Keywords: []string{"spuelarm", "spuelfeld", "wascharm", "spruehfeld"}, ComponentIDs: []string{"C004"}, ExtraTags: []string{"rotating_part"}},
|
// Spuelarm/Spuelfeld emit only the rotating_part capability tag. They are
|
||||||
|
// NOT mapped to a library component — C004 is a "Drehtisch" (rotary table)
|
||||||
|
// and that mislabels the spray arm. Keyword->component must be semantically
|
||||||
|
// honest (generic hygiene; surfaced by the warewashing GT).
|
||||||
|
{Keywords: []string{"spuelarm", "spuelfeld", "wascharm", "spruehfeld"}, ExtraTags: []string{"rotating_part"}},
|
||||||
{Keywords: []string{"spuelkammer", "spueltuer", "geraetetuer", "haubentuer", "klapptuer"}, ExtraTags: []string{"access_door"}},
|
{Keywords: []string{"spuelkammer", "spueltuer", "geraetetuer", "haubentuer", "klapptuer"}, ExtraTags: []string{"access_door"}},
|
||||||
// Ghost-Closure (Emit-Seite): macht die 34 toten Required-Tags
|
// Ghost-Closure (Emit-Seite): macht die 34 toten Required-Tags
|
||||||
// emittierbar, jeweils NUR via domaenenspezifische Keywords -> die 120
|
// emittierbar, jeweils NUR via domaenenspezifische Keywords -> die 120
|
||||||
|
|||||||
@@ -0,0 +1,233 @@
|
|||||||
|
{
|
||||||
|
"machine_name": "Gewerbliche Untertisch-Geschirrspuelmaschine (Winterhalter UC-M)",
|
||||||
|
"machine_description": "Untertisch-Gewerbespuelmaschine, vernetzt (Connected Wash), Heisswasser-Boiler, Spuelpumpe mit rotierenden Spuelfeldern, Tuer mit Sicherheitsschalter, Reiniger-/Klarspueler-Dosierung.",
|
||||||
|
"source": "Selbstbewertung GT #3 (Fachmann-Erwartung, EN 60335-2-58 + EN ISO 12100)",
|
||||||
|
"version": "1.0",
|
||||||
|
"entries": [
|
||||||
|
{
|
||||||
|
"nr": "1.1",
|
||||||
|
"hazard_group": "Thermische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Verbrühung durch Heißwasser und Dampf",
|
||||||
|
"hazard_cause": "Beim Öffnen der Tür während oder kurz nach dem Spülgang tritt heißes Wasser und Wrasen (Dampf) aus der Spülkammer aus und trifft Gesicht, Hände und Arme",
|
||||||
|
"lifecycle_phases": ["Betrieb", "Reinigung"],
|
||||||
|
"component_zone": "Tür und Beschickungsöffnung der Spülkammer",
|
||||||
|
"risk_in": {"f": 4, "w": 3, "p": 2, "s": 3, "r": 27},
|
||||||
|
"measures": ["Türverriegelung beendet Spülgang vor dem Öffnen", "Wrasen-/Dampfreduzierung", "Warnhinweis heißer Dampf"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 2, "w": 1, "p": 1, "s": 2, "r": 8},
|
||||||
|
"norm_references": ["EN 60335-2-58"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "1.2",
|
||||||
|
"hazard_group": "Thermische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Verbrennung an heißen Oberflächen",
|
||||||
|
"hazard_cause": "Berührung heißer Oberflächen von Boiler, Tankheizkörper oder Spülkammerwänden bei Reinigung, Entkalkung oder Wartung",
|
||||||
|
"lifecycle_phases": ["Reinigung", "Instandhaltung"],
|
||||||
|
"component_zone": "Boiler, Tankheizkörper, Spülkammerwände",
|
||||||
|
"risk_in": {"f": 3, "w": 2, "p": 2, "s": 2, "r": 14},
|
||||||
|
"measures": ["Temperaturbegrenzung zugänglicher Oberflächen", "Warnhinweis heiße Oberfläche"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 2, "r": 6},
|
||||||
|
"norm_references": ["EN ISO 13732-1"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "1.3",
|
||||||
|
"hazard_group": "Thermische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Verbrennung an heißem Spülgut",
|
||||||
|
"hazard_cause": "Geschirr und Gläser sind nach der Heißwasser-Nachspülung sehr heiß, beim Entladen kommt es zu Verbrennungen an den Händen",
|
||||||
|
"lifecycle_phases": ["Betrieb"],
|
||||||
|
"component_zone": "Spülkammer, Entnahmebereich, Korb",
|
||||||
|
"risk_in": {"f": 3, "w": 3, "p": 2, "s": 2, "r": 16},
|
||||||
|
"measures": ["Abkühl-/Trocknungszeit", "Warnhinweis heißes Spülgut"],
|
||||||
|
"measure_type": "BI",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 2, "r": 6},
|
||||||
|
"norm_references": ["EN 60335-2-58"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "2.1",
|
||||||
|
"hazard_group": "Gefährdungen durch Materialien und Substanzen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Verätzung von Haut und Augen durch Reiniger-/Klarspüler-Konzentrat",
|
||||||
|
"hazard_cause": "Direkter Kontakt mit dem ätzenden Reiniger- bzw. Klarspüler-Konzentrat beim Nachfüllen, Sauglanzenwechsel oder bei Leckage des Dosiergeräts",
|
||||||
|
"lifecycle_phases": ["Betrieb", "Instandhaltung"],
|
||||||
|
"component_zone": "Dosiergerät, Reiniger- und Klarspüler-Gebinde, Sauglanzen",
|
||||||
|
"risk_in": {"f": 3, "w": 3, "p": 2, "s": 3, "r": 24},
|
||||||
|
"measures": ["Geschlossenes Dosiersystem mit Sauglanzen", "PSA Augen-/Hautschutz", "GHS-Kennzeichnung und Sicherheitsdatenblatt"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 3, "r": 9},
|
||||||
|
"norm_references": ["Verordnung (EG) Nr. 1272/2008", "TRGS 500"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "2.2",
|
||||||
|
"hazard_group": "Gefährdungen durch Materialien und Substanzen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Reizung der Atemwege durch Reinigungs-Aerosole und Dämpfe",
|
||||||
|
"hazard_cause": "Einatmen von Aerosolen und Dämpfen der Reinigungschemie beim Öffnen kurz nach dem Spülgang oder bei der Entkalkung mit Säure",
|
||||||
|
"lifecycle_phases": ["Betrieb", "Instandhaltung"],
|
||||||
|
"component_zone": "Atemzone vor der Spülkammer, Aufstellbereich",
|
||||||
|
"risk_in": {"f": 2, "w": 2, "p": 2, "s": 2, "r": 12},
|
||||||
|
"measures": ["Be-/Entlüftung", "geschlossene Haube", "Warnung vor Vermischen von Reiniger und Säure"],
|
||||||
|
"measure_type": "BI",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 2, "r": 6},
|
||||||
|
"norm_references": ["TRGS 500"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "3.1",
|
||||||
|
"hazard_group": "Elektrische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Elektrischer Schlag in Nassumgebung",
|
||||||
|
"hazard_cause": "Berührung spannungsführender Teile bei unzureichendem IP-Schutz, defekten Kabeldurchführungen oder Feuchtigkeit im Steuerungsgehäuse",
|
||||||
|
"lifecycle_phases": ["Betrieb", "Reinigung", "Instandhaltung"],
|
||||||
|
"component_zone": "Steuerungsgehäuse, Kabelübergänge, Antriebsgehäuse",
|
||||||
|
"risk_in": {"f": 3, "w": 2, "p": 3, "s": 4, "r": 32},
|
||||||
|
"measures": ["IP-Schutz gegen eindringendes Wasser", "Fehlerstrom-Schutzeinrichtung (RCD)"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 4, "r": 12},
|
||||||
|
"norm_references": ["IEC 60335-1"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "3.2",
|
||||||
|
"hazard_group": "Elektrische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Kurzschluss und Brand bei Reinigung am Schaltschrank",
|
||||||
|
"hazard_cause": "Reinigung ohne vorherige Freischaltung oder mit Hochdruckreiniger am elektrisch aktiven Schaltschrank führt zu Kurzschluss und Brand",
|
||||||
|
"lifecycle_phases": ["Reinigung", "Instandhaltung"],
|
||||||
|
"component_zone": "Schaltschrank, elektrisch aktive Komponenten",
|
||||||
|
"risk_in": {"f": 2, "w": 2, "p": 2, "s": 3, "r": 18},
|
||||||
|
"measures": ["Netztrenneinrichtung", "Warnhinweis Reinigung nur spannungsfrei, kein Hochdruckreiniger"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 3, "r": 9},
|
||||||
|
"norm_references": ["IEC 60204-1"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "3.3",
|
||||||
|
"hazard_group": "Elektrische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Motorüberlast mit Überhitzung",
|
||||||
|
"hazard_cause": "Blockierter oder überlasteter Pumpenmotor überhitzt, Wicklungsbrand und Rauchentwicklung",
|
||||||
|
"lifecycle_phases": ["Betrieb"],
|
||||||
|
"component_zone": "Motorgehäuse, Umgebung",
|
||||||
|
"risk_in": {"f": 2, "w": 2, "p": 2, "s": 2, "r": 12},
|
||||||
|
"measures": ["Überstromschutz", "Motorschutzschalter"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 2, "r": 6},
|
||||||
|
"norm_references": ["IEC 60204-1"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "4.1",
|
||||||
|
"hazard_group": "Mechanische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Ausrutschen auf nassem Boden",
|
||||||
|
"hazard_cause": "Aus der Spülmaschine austretendes Wasser durch Leckage oder beim Öffnen macht den Boden im Aufstellbereich rutschig, Person rutscht aus und stürzt",
|
||||||
|
"lifecycle_phases": ["Betrieb", "Reinigung", "Instandhaltung"],
|
||||||
|
"component_zone": "Aufstell- und Bedienbereich der Spülmaschine",
|
||||||
|
"risk_in": {"f": 3, "w": 3, "p": 2, "s": 2, "r": 16},
|
||||||
|
"measures": ["Rutschhemmender Bodenbelag", "Bodenablauf bzw. Leckagewanne"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 2, "r": 6},
|
||||||
|
"norm_references": ["ASR A1.5/1,2"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "4.2",
|
||||||
|
"hazard_group": "Mechanische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Quetschen der Finger an der Tür/Haube",
|
||||||
|
"hazard_cause": "Beim Schließen der Tür bzw. Absenken der Haube werden Finger zwischen Tür/Haube und Gehäuse gequetscht",
|
||||||
|
"lifecycle_phases": ["Betrieb"],
|
||||||
|
"component_zone": "Tür- und Haubenkante, Schließbereich",
|
||||||
|
"risk_in": {"f": 3, "w": 2, "p": 2, "s": 1, "r": 7},
|
||||||
|
"measures": ["Geringe Schließkraft, Einklemmschutz", "Abgerundete Türkanten"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 1, "r": 3},
|
||||||
|
"norm_references": ["EN ISO 12100"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "4.3",
|
||||||
|
"hazard_group": "Mechanische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Kontakt mit rotierendem Spülarm bei geöffneter Tür",
|
||||||
|
"hazard_cause": "Eingreifen in die Spülkammer bei noch nachlaufendem rotierendem Spülarm/Spülfeld nach dem Öffnen der Tür",
|
||||||
|
"lifecycle_phases": ["Betrieb", "Reinigung"],
|
||||||
|
"component_zone": "Spülkammer, Spülarm und Spülfeld",
|
||||||
|
"risk_in": {"f": 2, "w": 2, "p": 2, "s": 1, "r": 6},
|
||||||
|
"measures": ["Türverriegelung stoppt Spülarm beim Öffnen"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 1, "r": 3},
|
||||||
|
"norm_references": ["EN ISO 12100"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "5.1",
|
||||||
|
"hazard_group": "Ergonomische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Belastung des Bewegungsapparats durch wiederholte Be- und Entladung",
|
||||||
|
"hazard_cause": "Wiederholtes Heben und Bücken beim manuellen Be- und Entladen der Spülkörbe am Untertischgerät",
|
||||||
|
"lifecycle_phases": ["Betrieb"],
|
||||||
|
"component_zone": "Be- und Entladestelle, Spülkorb",
|
||||||
|
"risk_in": {"f": 4, "w": 3, "p": 2, "s": 1, "r": 9},
|
||||||
|
"measures": ["Ergonomische Arbeitshöhe", "Be-/Entladung auf günstiger Greifhöhe"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 2, "w": 1, "p": 1, "s": 1, "r": 4},
|
||||||
|
"norm_references": ["EN 1005-2"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "5.2",
|
||||||
|
"hazard_group": "Ergonomische Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Zwangshaltung durch ungünstige Bedienelement-Position",
|
||||||
|
"hazard_cause": "Bedienelemente am HMI außerhalb der ergonomisch günstigen Reichweite führen bei dauerhafter Bedienung zu Zwangshaltung",
|
||||||
|
"lifecycle_phases": ["Betrieb"],
|
||||||
|
"component_zone": "Bedienstand HMI, Steuerpult",
|
||||||
|
"risk_in": {"f": 3, "w": 2, "p": 1, "s": 1, "r": 6},
|
||||||
|
"measures": ["Bedienelemente in ergonomisch günstiger Höhe"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 1, "r": 3},
|
||||||
|
"norm_references": ["EN 894-3"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "6.1",
|
||||||
|
"hazard_group": "zusätzliche Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Verlust einer Sicherheitsfunktion durch Steuerungs- oder Softwarefehler",
|
||||||
|
"hazard_cause": "Steuerungs- oder Softwarefehler der eigenen Maschinensteuerung führt zu unkontrolliertem Verhalten oder Verlust einer Sicherheitsfunktion",
|
||||||
|
"lifecycle_phases": ["Betrieb", "Instandhaltung"],
|
||||||
|
"component_zone": "Gesamte Maschine, Steuerung",
|
||||||
|
"risk_in": {"f": 2, "w": 2, "p": 2, "s": 3, "r": 18},
|
||||||
|
"measures": ["Sichere Fehlerbehandlung", "Sichere Software-Fallbacks", "Watchdog"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 3, "r": 9},
|
||||||
|
"norm_references": ["EN ISO 13849-1"],
|
||||||
|
"sufficient": true
|
||||||
|
},
|
||||||
|
{
|
||||||
|
"nr": "6.2",
|
||||||
|
"hazard_group": "zusätzliche Gefährdungen",
|
||||||
|
"hazard_group_applicable": true,
|
||||||
|
"hazard_type": "Verlust der Sicherheitsfunktion nach fehlerhaftem Software-Update",
|
||||||
|
"hazard_cause": "Korrupte oder inkompatible Firmware nach fehlerhaftem Update über die USB-Schnittstelle lässt die Steuerung undefiniert verhalten oder Sicherheitsfunktion verlieren",
|
||||||
|
"lifecycle_phases": ["Instandhaltung"],
|
||||||
|
"component_zone": "Gesamte Maschine, Steuerung, Update-Schnittstelle",
|
||||||
|
"risk_in": {"f": 2, "w": 2, "p": 2, "s": 3, "r": 18},
|
||||||
|
"measures": ["Atomares Update mit Rückfall auf lauffähige Version", "Kompatibilitätsprüfung vor Update"],
|
||||||
|
"measure_type": "KM",
|
||||||
|
"risk_out": {"f": 1, "w": 1, "p": 1, "s": 3, "r": 9},
|
||||||
|
"norm_references": ["EN ISO 13849-1"],
|
||||||
|
"sufficient": true
|
||||||
|
}
|
||||||
|
]
|
||||||
|
}
|
||||||
Reference in New Issue