fix(iace): resolve M-ID collisions for electrical/pressure patterns
6 supplementary measures (M410-M420) were silently overwritten by metalworking duplicates in measureByID lookups, so robot-cell electrical patterns resolved to chip-extraction/cleaning fallbacks instead of equipotential bonding, creepage, EMC, or hose-burst protection. Rename supplementary IDs to M475-M480 and rewire 13 affected pattern references in robot_cell + robot_cell_ext. HP1640 (direct contact with live parts, GT 2.2): priority 98->99, drop RequiredEnergyTags gate so it fires in robot cells without an electrical tag, expand mitigations to 5 concrete TRBS 2131 / IEC 60204-1 / EN 61140 measures (basic protection, double insulation, earthing, insulation monitoring, equipotential bonding) — was previously losing to HP1688 even though HP1688 describes a different scenario. HP1688 (touch voltage from potential differences): priority 98->96 so it no longer outranks HP1640 for the direct-contact case; mitigations expanded from M410-only to 4 concrete electrical measures. Add regression tests pinning HP1640 contact-protection resolution and M475 = Potentialausgleich. Existing TestGetProtectiveMeasureLibrary_- UniqueIDs now actually enforces uniqueness (previously masked by last-wins map override). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -192,7 +192,7 @@ func GetRobotCellPatternsExt() []HazardPattern {
|
||||
ID: "HP1675", NameDE: "KSS-Schlauch bersten oder abspringen", NameEN: "Coolant hose burst or detachment",
|
||||
RequiredComponentTags: []string{},
|
||||
GeneratedHazardCats: []string{"mechanical_hazard"},
|
||||
SuggestedMeasureIDs: []string{"M420"},
|
||||
SuggestedMeasureIDs: []string{"M480"},
|
||||
Priority: 97, MachineTypes: []string{"cnc", "metalworking", "automotive"},
|
||||
ApplicableLifecycles: []string{"normal_operation", "setup", "maintenance", "fault_clearing"},
|
||||
ScenarioDE: "Schlauch der Kuehlschmierstoffversorgung zwischen Aufbereitungsanlage und Bearbeitungszentrum platzt oder springt unter Druck ab.",
|
||||
@@ -226,7 +226,7 @@ func GetRobotCellPatternsExt() []HazardPattern {
|
||||
ID: "HP1685", NameDE: "Indirektes Beruehren durch Schutzleiterunterbrechung", NameEN: "Indirect contact due to PE interruption",
|
||||
RequiredComponentTags: []string{},
|
||||
GeneratedHazardCats: []string{"electrical_hazard"},
|
||||
SuggestedMeasureIDs: []string{"M410", "M411"},
|
||||
SuggestedMeasureIDs: []string{"M475", "M476"},
|
||||
Priority: 98,
|
||||
ApplicableLifecycles: []string{"normal_operation", "setup", "cleaning", "maintenance", "fault_clearing"},
|
||||
ScenarioDE: "Schutzleiter ist unterbrochen. Person beruehrt leitfaehige Maschinenteile und erleidet elektrischen Schlag.",
|
||||
@@ -268,8 +268,8 @@ func GetRobotCellPatternsExt() []HazardPattern {
|
||||
ID: "HP1688", NameDE: "Gefaehrliche Beruehrungsspannung durch Potentialunterschiede", NameEN: "Dangerous touch voltage from potential differences",
|
||||
RequiredComponentTags: []string{},
|
||||
GeneratedHazardCats: []string{"electrical_hazard"},
|
||||
SuggestedMeasureIDs: []string{"M410"},
|
||||
Priority: 98,
|
||||
SuggestedMeasureIDs: []string{"M475", "M477", "M138", "M329"},
|
||||
Priority: 96,
|
||||
ApplicableLifecycles: []string{"normal_operation", "setup", "maintenance", "fault_clearing"},
|
||||
ScenarioDE: "Person beruehrt gleichzeitig Anlagenteile mit unterschiedlichem Potential und erleidet elektrischen Schlag.",
|
||||
TriggerDE: "Fehlender Potentialausgleich zwischen Anlagenteilen verschiedener Hersteller.",
|
||||
@@ -282,7 +282,7 @@ func GetRobotCellPatternsExt() []HazardPattern {
|
||||
ID: "HP1689", NameDE: "Fehlerstromschutz an Steckdosenstromkreisen", NameEN: "RCD protection at socket circuits",
|
||||
RequiredComponentTags: []string{},
|
||||
GeneratedHazardCats: []string{"electrical_hazard"},
|
||||
SuggestedMeasureIDs: []string{"M410"},
|
||||
SuggestedMeasureIDs: []string{"M475"},
|
||||
Priority: 97,
|
||||
ApplicableLifecycles: []string{"normal_operation", "setup", "maintenance", "fault_clearing"},
|
||||
ScenarioDE: "Defektes Geraet wird an Steckdose der Maschine angeschlossen. Fehlerstrom fliesst ueber den Koerper der beruerenden Person.",
|
||||
@@ -364,7 +364,7 @@ func GetRobotCellPatternsExt() []HazardPattern {
|
||||
ID: "HP1698", NameDE: "Kurzschluss durch unzureichende Luft-/Kriechstrecken", NameEN: "Short circuit from insufficient creepage/clearance",
|
||||
RequiredComponentTags: []string{},
|
||||
GeneratedHazardCats: []string{"electrical_hazard"},
|
||||
SuggestedMeasureIDs: []string{"M412"},
|
||||
SuggestedMeasureIDs: []string{"M477"},
|
||||
Priority: 98,
|
||||
ApplicableLifecycles: []string{"normal_operation", "setup", "maintenance", "fault_clearing"},
|
||||
ScenarioDE: "Unzureichende Luft-/Kriechstrecken fuehren bei Verschmutzung zu Kriechstroemen. Person beruehrt betroffene Teile und erleidet elektrischen Schlag.",
|
||||
@@ -378,7 +378,7 @@ func GetRobotCellPatternsExt() []HazardPattern {
|
||||
ID: "HP1699", NameDE: "EMV-Stoereinfluss auf Sicherheitsfunktionen", NameEN: "EMC interference with safety functions",
|
||||
RequiredComponentTags: []string{},
|
||||
GeneratedHazardCats: []string{"radiation_hazard"},
|
||||
SuggestedMeasureIDs: []string{"M415", "M416"},
|
||||
SuggestedMeasureIDs: []string{"M478", "M479"},
|
||||
Priority: 97,
|
||||
ApplicableLifecycles: []string{"normal_operation", "setup"},
|
||||
ScenarioDE: "EMV-Stoerungen verursachen unerwartete Maschinenbewegungen. Person im Gefahrenbereich wird von unkontrolliert bewegten Teilen getroffen.",
|
||||
@@ -423,7 +423,7 @@ func GetRobotCellPatternsExt() []HazardPattern {
|
||||
ID: "HP1702", NameDE: "KSS-Schlauch platzt unter Druck", NameEN: "Coolant hose bursts under pressure",
|
||||
RequiredComponentTags: []string{},
|
||||
GeneratedHazardCats: []string{"mechanical_hazard"},
|
||||
SuggestedMeasureIDs: []string{"M420"},
|
||||
SuggestedMeasureIDs: []string{"M480"},
|
||||
Priority: 97, MachineTypes: []string{"cnc", "metalworking", "automotive"},
|
||||
ApplicableLifecycles: []string{"normal_operation", "maintenance", "fault_clearing"},
|
||||
ScenarioDE: "KSS-Schlauch platzt und spritzt Kuehlschmierstoff unter Druck. Person in der Naehe wird von KSS-Strahl getroffen.",
|
||||
@@ -451,7 +451,7 @@ func GetRobotCellPatternsExt() []HazardPattern {
|
||||
ID: "HP1704", NameDE: "Brand durch KSS-Leckage auf elektrische Komponenten", NameEN: "Fire from coolant leakage on electrical components",
|
||||
RequiredComponentTags: []string{},
|
||||
GeneratedHazardCats: []string{"electrical_hazard"},
|
||||
SuggestedMeasureIDs: []string{"M420", "M009"},
|
||||
SuggestedMeasureIDs: []string{"M480", "M009"},
|
||||
Priority: 98, MachineTypes: []string{"cnc", "metalworking", "automotive"},
|
||||
ApplicableLifecycles: []string{"normal_operation", "cleaning", "maintenance"},
|
||||
ScenarioDE: "KSS-Leckage tropft auf elektrische Komponenten und verursacht Kurzschluss. Person wird durch Brand oder Rauchentwicklung gefaehrdet.",
|
||||
|
||||